7.  Violate a detection zone (open a door, window, etc.). The keypad will 
beep continuously and the indicator of the corresponding zone will 
light. 
8.  Secure the zone (close the door, window, etc.). The keypad 
beeping will cease. 
9.  The interior detection devices will also cause the keypad to 
beep if 
entering those protected areas when testing unless the 
INTERIOR is 
first turned OFF. You may also want to walk test motion 
detection 
devices to check whether the pattern is covering the areas 
of concern. 
10.  Begin at step five to test the remaining sensors. 
11.  Press the Reset (*) key when finished testing. 
NOTE 
Your system should be regularly tested at least once per week to insure proper 
operation. For UL Listed Burglar systems, the Bell Test should be included as part 
of the weekly test. Contact your security company representative for complete 
instructions on regular system maintenance and testing procedures. If the wall 
mounted transformer which powers the system is removed for any reason, test 
the system to see if the standby battery is adequately powering the system. 
Reconnect the transformer, secure to the wall plate with the restraining tab 
machine screw, and test the system again to assure it is receiving AC power. 