Startup:
1. Remove 2 screws and lid.
2. Install 2 AAA batteries. 2, AAA Energizer Ultimate Lithium batteries are required. Note: Battery
orientation is shown in the bottom of the sensor under each battery.
Cellular:
3. Sensor will beep 2x when batteries are inserted. Wait for 3 beeps, to indicate successful
cellular/cloud connection. First start up may take longer to achieve 3 beeps because of initial
cellular provisioning.
4. Note: Any time button is pressed, data will also be uploaded to the cloud. So, for example, after
pressing the button to sync the sensor to the app, you will hear 3 beeps after data is uploaded to
the cloud.
5. Reinstall lid and screws. Torque = 9 in lbs.
6. Scan QR code on sensor. The automated link in the QR code will open the Mopeka cloud to enter
all the relevant information required, such as customer name, tank size, etc.
7. After all customer information is entered, push the sync button on sensor (1x, and immediately
release) to initiate a data upload to the cloud.
8. System is now ready to install the sensor on the tank.
Installation:
9. Prior to installation, install sonic grease on center pad as shown.
10. Push and hold sync button (3 seconds) until beeping starts.
11. The beeping is an indicator of the correct installation position and ultrasonic function.
12. Note: LED light will flash simultaneously with beeper, as visual indicator if background noise
makes hearing beeper difficult.
13. Beeping will be rapid when button is first pressed.