Operation Manual

11
section 3 - tecHnicAL DAtA
3952.5
2.5
from case
700
Side
flue
dim. A
285
86.5
17
155
CH FLOW
DHW OUTLET
COND. DRAIN
GAS INLET
DHW INLET
CH RETURN
PRV
43.5 65
28.5 28.5
60.6 75 37.556.4
Underside View - Dimensions to Wall
W A L L
W A L L
99
103 99
99 103
Table 3 - Performance Data - Domestic Hot Water
BOILER DIMENSIONS, SERVICES & CLEARANCES
Theboilerconnectionsaremadeontheboilerbulkheadttings.
The following minimum clearances must be maintained for
operation and servicing.
Additional space will be required for installation, depending upon
site conditions.
Side and Rear Flue
a. Providedthattheueholeiscutaccurately,e.g.withacore
boringtoolorholecuttertheuecanbeinstalledfrominside
the dwelling where wall thicknesses do not exceed 600mm
(24”). Where the space into which the boiler is going to be
installedislessthanthelengthofuerequiredtheuemust
bettedfromtheoutside.
Installation from inside ONLY
b. If a core boring tool or hole cutter is to be used inside the
dwelling the space in which the boiler is to be installed
must be at least wide enough to accommodate the tool.
In either of the above cases safe external access is
required to allow the addition of sealant to seal the ue to
the spinning.
Front clearance
The minimum front clearance when
built in to a cupboard is 5mm from
the cupboard door but 450mm overall
clearance is still required, with the
cupboard door open, to allow for
servicing.
* Bottom clearance
Bottom clearance after installation
can be reduced to 5mm.
This must be obtained with an
easily removable panel, to enable
the consumer to view the system
pressure gauge, and to provide
the 100mm clearance required for
servicing.
Max 30kW
Max 24kW
2.Foruelengthsrequiring“D”packextensions(RSF341),theuemustinclineby26mmper1Metreofuelength.