Operation Manual

30
SECTION 7 - ROuTINE SERvICINg INSTRuCTIONS
7.10
FLAME DETECTION ELECTRODE
7.11
FINAL CHECKS
Flame Detection Electrode
12.5mm
Straight edge
1. Remove the burner. Refer to Frame 7.8.
2. Check dimensions are correct as in diagram
below.
3. Reassemble in reverse order.
FOR REMOVAL:
1. Unplug the ignition lead and remove the earth
lead.
2. Remove the 2 retaining screws and remove the
electrode.
3. Reassemble in reverse order replacing the
gasket if necessary.
Turn all controls to “ON” position and check their correct functions in both DHW & CH modes.
Additional replacement of parts information can be found on our website. www.morcoproducts.co.uk