Operating Instructions and Installation Instructions
16
section 5 - installation instructions
5.7 DETERMINING THE FLUE LENGTH
IMPORTANT. The boiler must be installed in a vertical position in accordance to the installation instructions.
STANDARD FLUE KITS
-contains:Flueturret,nontelescopicsinglepieceueincorporatingaterminal
and inner rubber wall seal.
Extension Kit RSF341 -contains:1metrelengthofuepipe(Functionallength950mm),1supportbracket.
When extension kits are used the ue duct must incline 1.5 degrees away from the appliance, to allow the condensate to drain back to
the boiler and out of the condensate drain. It is recommended that a support bracket is tted on every 1 metre of pipe work used and the
bracket is located as close to the collar as possible. The bracketing must ensure a 1.5 degree fall back to the appliance.
Only use water as a lubricant during assembly.
Thehorizontaluekitterminalisclassedaspartofthemaximumuelength.
create an adequate seal.
WALL
Aluminium Flue
Collar (RSF 060)
Fill with
sealant
17mm min
Internal Sealing
Flubber
Fill with
sealant
ItisIMPORTANTthatallattachmentsarettedinaccordancewiththeinstallationinstructionsprovidedinthismanual.
TheTURRETsuppliedintheHorizontalFlueKits(RSF303&RSF305)hasanuppercombustionsamplepointwithascrewcapseal
andalowerairsamplepointwithanairstopperseal.Ensureallcaps&sealsareinplace.
Additional Termination KitsavailableforusewiththeseHorizontalFlueKits(RSF303&RSF305)
FlueDeectorKit(RSF300) Theresistanceistheequivalentof1metreofuepipeandthereforemustbedeductedfrom
anymaximumuelength
Total Maximum Permissible Horizontal Concentric Flue Length combining both Horizontal Flue Kits and Extension Kits
(Measuredfromcentrelineoftheturrettotheoutsidefaceofthealuminiumuecollar(RSF060))
24 kW appliances TotalMaximum:8metres-minusanyuekitoptions
30 kW Appliances TotalMaximum:7metres-minusanyuekitoptions
Total Maximum Permissible Vertical Flue Length
24&30kWAppliances Total Maximum: 7.5 Metres - minus any 90º bends
Minimum Horizontal Flue Lengths (Centrelineofturrettooutsidefaceofthealuminiumuecollar(RSF060))
Rear Flue - 191mm
Side Flue - 236mm (with minimum 2.5mm clearance)