Installation Manual

64 APPENDICES 65 MORNINGSTAR CORPORATION
Appendices
DIP Switches Number 4,5,6 - Lighting Control Algorithm:
For Lighting Control mode, set the DIP switches 4,5,& 6 according to
the table below.
hrs hrs
after before
Sunset Sunrise Switch 4 Switch 5 Switch 6
6 0 Off Off Off
8 0 Off Off On
10 0 Off On Off
3 1 Off On On
4 2 On Off Off
6 2 On Off On
Dusk to Dawn On On Off
Custom On On On
6 hours
after sunset
123 456 78
DIPON
123 456 78
DIPON
123 456 78
DIPON
123 456 78
DIPON
ON
OFF
123 45678
DIPON
123 45678
DIPON
123 45678
DIPON
123 45678
DIPON
8 hours
after sunset
10 hours
after sunset
3 hours
after sunset,
1 hour
before sunrise
4 hours
after sunset,
2 hours
before sunrise
6 hours
after sunset,
2 hours
before sunrise
Dusk to Dawn
Custom Settings
Figure A1-5 - Step 3 DIP Switch # 4,5,6
Select one of the 7 standard Lighting Control algorithms, or select the
“custom” DIP switch for special custom settings using the PC software.
The default LVD and LVD reconnect settings for Lighting Control are listed below.
These values can be changed in custom settings.
LVD 11.40 Volts
LVDR 13.00 Volts
DIP Switch Number 7 - Must be OFF:
Switch 7
Off
OFF
123456 7 8
DIPON
ON
OFF
Figure A1-6 - Step 3 DIP Switch # 7
In Load Control and Lighting modes, DIP switch #7 must be in the OFF
position.
DIP Switch Number 8 - Lighting Control:
Control Switch 8
Lighting Disabled Off
Lighting Enabled On
Lighting
OFF
1 2 3 4 5 6 7 8
DIPON
ON
OFF
Lighting
ON
1 2 3 4 5 6 7 8
DIPON
Figure A1-7 - Step 3 DIP Switch # 8
To enable lighting control, DIP switch #8 must be in the ON position.
NOTE: Confirm all dip-switch settings before going to the next
installation steps.
REMARQUE : Confirmez les réglages de tous les commutateurs dip
avant de passer aux étapes suivantes d’installation.