Installation Guide

1.0
Important Safety Instructions
ProStar MPPT Operator’s Manual
32
AVERTISSEMENT: Risque De Choc Électrique.
NON ALIMENTATION OU AUX BORNES
D'ACCESSOIRES SONT ISOLÉS ÉLECTRIQUEMENT DE
L'ENTRÉE DE C.C ET DOIT ÊTRE ALIMENTÉS À UNE TENSION
DANGEREUSE SOLAIRE. SOUS CERTAINES CONDITIONS
DE DÉFAILLANCE, LA BATTERIE POURRAIT DEVENIR TROP
CHARGÉE. TEST ENTRE TOUTES LES BORNES ET LA MASSE
AVANT DE TOUCHER.
AVERTISSEMENT: LE PORT DE COMMUNICATION EST
CONSIDÉRÉE COMME DVC B. UN ISOLATEUR EXTERNE
N'EST NÉCES SAIRE SI C'EST D'ÊTRE CONNECTÉ À UN DVC
UN CIRCUIT.
External solaire et la batterie se déconnecte sont
nécessaires.
Déconnectez toutes les sources d’alimentation du
contrôleur avant d’installer ou de régler le ProStar MPPT.
Le ProStar MPPT MPPT ne contient aucun fusible ou inter-
rupteur. Ne tentez pas de réparer.
Installez des fusibles/coupe-circuits externes selon le
besoin.
Installation Safety Precautions
WARNING: This unit is not provided with a GFDI device.
This charge controller must be used with an external
GFDI device as required by the Article 690 of the
National Electrical Code for the installation location.
Mount the ProStar MPPT indoors. Prevent exposure to the
elements and do not allow water to enter the controller.
Install the ProStar MPPT in a location that prevents casual
contact. The ProStar MPPT heatsink can become very hot
during operation.
Use insulated tools when working with batteries.
Avoid wearing jewelry during installation.
Safety Information
Read all of the instructions and cautions in the manual
before beginning installation.
There are no user serviceable parts inside the
ProStar MPPT. Do not disassemble or attempt to repair
the controller.
WARNING: Risk Of Electrical Shock.
NO POWER OR ACCESSORY TERMINALS ARE
ELECTRICALLY ISOLATED FROM DC INPUT, AND MAY BE
ENERGIZED WITH HAZARDOUS SOLAR VOLTAGE. UNDER
CERTAIN FAULT CONDITIONS, BATTERY COULD BECOME
OVER-CHARGED. TEST BETWEEN ALL TERMINALS AND
GROUND BEFORE TOUCHING.
WARNING: THE COMMUNICATIONS PORT IS
CONSIDERED TO BE DVC B. AN EXTERNAL
ISOLATOR IS REQUIRED IF IT IS TO BE CONNECTED TO A DVC
A CIRCUIT.
External solar and battery disconnects are required.
Disconnect all sources of power to the controller before
installing or adjusting the ProStar MPPT.
There are no fuses or disconnects inside the ProStar MPPT
Do not attempt to repair.
Informations de Sécurité
Lisez toutes les instructions et les avertissements figurant
dans le manuel avant de commencer l’installation.
Le ProStar MPPT ne contient aucune pièce réparable par
l’utilisateur. Ne démontez pas ni ne tentez de réparer le
contrôleur.