4.0OPERATION
MORNINGSTARCORPORATION 33
willdetectthebatteryandprovideapproximately85%
ofavailablechargecurrentuntilthebatteryreachesthe
minimumoperatingvoltageofthecontroller.Whenthe
batteryhasrechargedtotheminimumoperatingvoltageof
theSunSaver,100%ofavailablechargecurrentwillowto
thebatteryandnormaloperationwillresume.
4.3 Load Control Information
Theprimarypurposeoftheloadcontrolfunctionisto
disconnectsystemloadswhenthebatteryhasdischarged
toalowstateofchargeandreconnectsystemloadswhen
thebatteryissufcientlyrecharged.Systemloadsmaybe
lights,pumps,motors,DCappliances,andotherelectronic
devices.Thetotalcurrentdrawofallloadsmustnotexceed
theSunSavermaximumloadrating.
NOTE:
Do not wire an AC inverter of any size to the load termi-
nals of the SunSaver. Damage to the load control circuit
may result. Connect inverters directly to the battery or
battery bank.
Load Control Settings
Loadcontrolisfullyautomatic.Theloadwillbe
disconnectedandreconnectedbasedupontheLowVoltage
Disconnect(LVD)andLowVoltageReconnect(LVR)voltage
thresholds.TheLVDandLVRthresholdsarelistedinthe
backofthemanual.
LVD Warning
AsthebatterydischargestheBattery StatusLEDswill
transitionfromgreentoyellowandthenfromyellowto
ashingred.Theashingredindicationisawarningthata
lowvoltagedisconnecteventwilloccursoon.Theamountof
timebetweenagreenSOCindicationandloaddisconnect
willdependonmanyfactorsincluding:
• rateofdischarge(amountofloaddraw)
• capacityofthebattery
• healthofthebattery
• LVDsetpoint
IfthebatterydischargestotheLVDsetpointtheloadwill
disconnectandasolidredBatteryStatusLEDindicationwill
bedisplayed.
General Load Control Notes
• OnlySS-6L/10L/20Lmodelsprovideloadcontrol.
• A15Vmaximumregulationvoltagelimit(30V@24V
nominal)existsforallbatterytypes.Thislimitensures
thatthebatteryandloadterminalvoltageswillnever
exceed15V/30V.ThisprotectscertainDCloadsthat
maybedamagedbyhighinputvoltage.
• Theload
connectionisNOT
aregulatedvoltage
output.Theloadterminalvoltageisapproximatelythe
sameasbatteryvoltageunlessthecontrollerisinLVD
condition(loadturnedoff).
• DonotwiremultipleSunSaverloadoutputstogetherin
paralleltopowerDCloadswithacurrentdrawgreater
thanthelowestratedcontroller’smaximumloadrating.
Equalcurrentsharingcannotbeguaranteedandan
over-loadconditionwilllikelyoccurononeormore
controllers.
• Exercisecautionwhenconnectingloadswithspecic
polaritytoaliveloadcircuit.Areversepolaritycon-
nectionmaydamagetheload.Alwaysre-checkload
connectionsbeforeapplyingpower.
• TheSunSaverwillgostraighttoLVDonstart-upifthe
batteryvoltageisatorbelow11.7V/23.4V.