SunSaver Operator’s Manual

MORNINGSTAR CORPORATION
15
2.0 GENERAL INFORMATION
14
This Class B digital apparatus complies with Canadian
ICES-003.
Cet appareil numerique de la classe B est conforme a la
norme NMB-003 du Canada.
3.0 INSTALLATION INSTRUCTIONS
3.1 General Installation Notes
Read through the entire installation section before
beginning installation.
Be very careful when working with batteries. Wear
eye protection. Have fresh water available to wash
and clean any contact with battery acid.
Use insulated tools and avoid placing metal objects
near the batteries.
Explosive battery gases may be present during charg-
ing. Be certain there is sufcient ventilation to
release the gases.
Do not install in locations where water can enter the
controller.
Loose power connections and/or corroded wires
may result in resistive connections that melt wire
insulation, burn surrounding materials, or even cause
re. Ensure tight connections and use cable clamps
to secure cables and prevent them from swaying in
mobile applications.
The SunSaver charging algorithm is compatible with
lead-acid or NiCd batteries. NiMH, Li-ion, and other
battery chemistries are not compatible with the
SunSaver charging algorithm.
The SunSaver Battery connection may be wired
to one battery or a bank of batteries. The following
instructions refer to a singular battery, but it is implied
that the battery connection can be made to either one
battery or a group of batteries in a battery bank.
2
3 .0