Communications Document

23Morningstar Product Connectivity Manual
3.4.2 Addressing
To enable devices on the network to communicate with each other, each one must be assigned
a unique MeterBus
TM
ID. Only 15 devices are allowed on a single network, therefore, the range
of acceptable MeterBus
TM
IDs is 1 to 15. There are two manners in which you can assign these
addresses: using a TS Meter/TS Remote Meter or by using a PC.
NOTE: Morningstar recommends using a TS Meter 2/TS
Remote Meter 2 for addressing due to its simplicity and
speed.
3.4.2.1 Meter or Remote Meter (TriStar / TS-MPPT only)
A TriStar Meter is capable of addressing each TriStar device on the MeterBus
TM
network before
they are connected. Attach the meter to the device you want to address and use the TS-M 2 / TS-
RM 2 manual and meter map to set the desired MeterBus
TM
ID.
Do this for all the TS controllers on the network, making sure that no two devices have the same
address. Two devices with the same address will cause communications problems on the net-
work and unexpected behavior will result.
3.4.2.2 PC Connection (all devices)
A PC can be used to individually connect and assign MeterBus
TM
IDs to Morningstar products.
This is accomplished through the use of Morningstar’s MSView
TM
software package. For informa-
tiononhowtoinstallandconguredevicesusingMSView
TM
, please refer to Section 5.0.
All devices on the network, except for the Meter Hub and TS Meters, need to be programmed
individually. Connect to the network devices one by one and use the MSView
TM
software to as-
sign IDs that are unique on the network. MSView
TM
’s Setup Wizards are an invaluable tool for this
task.
Make sure no two devices have the same ID on the network. Two devices with the same address
will cause communications problems and unexpected behavior will result.
3.4.3 Verication
Use a network Meter (TS-M 2 or TS-RM 2) to view data for each controller/inverter on the net-
work. Make sure that all network devices are accessible through the meter and that aggregate
meter data is an accurate account of the system as a whole.