MPPT 60 User Manual

61 Warranty and Claim Procedure
60
Troubleshooting
NOTE:
For more in-depth testing and diagnosis, download the TriStar MPPT 150V Testing Document
from the Support section on our website: www.morningstarcorp.com/
Network and Communication Issues
Problem:
Cannot connect to the controller via RS-232
Solution:
Check the following:
The RS-232 cable is straight-through, not a Null Modem (cross-over)
If using a serial-USB adapter, verify that the adapter software is installed and a serial COM
port has been mapped. Check the activity light on the USB adapter if it has one. If there is
no activity, the wrong COM port has been chosen or there is a conguration issue with the
adapter.
The default MODBUS ID of the TriStar MPPT 150V is 1. Verify that the PC software is
congured to communicate using the correct MODBUS ID.
Problem:
Cannot connect to the controller via EIA-485
Solution:
Check the following:
The RS-232 port is not in use. The EIA-485 and RS-232 ports cannot be used simultane-
ously. Only one port can be used at a time.
The RSC-1 adapter used to connect the PC to the EIA-485 network shows a green LED
and pulses red when a connection is attempted. See the RSC-1 documentation for more
information.
Each controller or device on the EIA-485 network has been programmed with a unique
MODBUS ID.
A serial cross-over (Null Modem) cable is used for the connection between the PC and the
Morningstar RSC-1 485 Adapter. A straight-through serial cable will not work.
Power is supplied to the 4-wire bus on the Power/Ground lines. The bus requires voltage
in the range: 8 - 16 Vdc.
All bus connections are secure and each terminal is wired in parallel: line A to line A, line B
to line B, etc.
Problem:
Cannot connect to the controller via Ethernet
Solution:
See the TriStar MPPT 150V Networking Companion Document, available on our website.
LIMITED WARRANTY Morningstar Solar Controllers and Inverters
The TriStar MPPT 150V is warrantied to be free from defects in material and workmanship for a
period of FIVE (5) years from the date of shipment to the original end user. Morningstar will, at its
option, repair or replace any such defective units.
WARRANTY EXCLUSIONS AND LIMITATIONS:
This warranty does not apply under the following conditions:
Damage by accident, negligence, abuse or improper use
PV or load currents exceeding the ratings of the product
Unauthorized product modification or attempted repair
Damage occurring during shipment
Damage results from acts of nature such as lightning and weather extremes
THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU
OF ALL OTHERS, EXPRESS OR IMPLIED. MORNINGSTAR SPECIFICALLY DISCLAIMS
ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WAR-
RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. NO
MORNINGSTAR DISTRIBUTOR, AGENT OR EMPLOYEE IS AUTHORIZED TO MAKE
ANY MODIFICATION OR EXTENSION TO THIS WARRANTY.
MORNINGSTAR IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL
DAMAGES OF ANY KIND, INCLUDING BUT NOT LIMITED TO LOST PROFITS,
DOWN-TIME, GOODWILL OR DAMAGE TO EQUIPMENT OR PROPERTY.
Warranty and Claim Procedure7.0