Key Features and Benets
SOLAR CONTROLLER WITH MAXIMUM
POWER POINT TRACKING
Product shown with optional meter.
30, 45 or 60 amps
at up to 150 volts
open circuit
Morningstar’s TriStar MPPT solar controller with TrakStar Technology™ is an advanced maximum power point
tracking (MPPT) battery charger for off-grid photovoltaic (PV) systems up to 3kW. The controller provides the
industrys highest peak efficiency of 99% and significantly less power loss compared to other MPPT controllers.
The TriStar MPPT features a smart tracking algorithm that maximizes the energy harvest from the PV by rapidly
finding the solar array peak power point with extremely fast sweeping of the entire I-V curve. This product is the
first PV controller to include on-board Ethernet for a fully web-enabled interface and includes up to 200 days of
data logging.
Maximizes Energy Harvest
Our TrakStar MPPT Technology features:
Better peak power point tracking than other MPPT
controllers
Very fast sweeping of the entire I-V curve
Recognition of multiple power points during shading or
mixed PV arrays
Excellent performance at sunrise and low solar
insolation levels
Extremely High Reliability
Robust thermal design and no cooling fans
Parallel circuit design provides less stress and longer
life for electronic components
No mechanical relays
Extensive electronic protections including PV short
circuit protection
Epoxy encapsulated inductors and conformally coated
printed circuit boards
Very High Efficiency
Peak efficiency of 99%
Proprietary tracking algorithm minimizes power losses
Low self-consumption
Continuous operation at full power to 45°C without
need to de-rate
Selected electronic devices with higher ratings to
minimize losses from heating
Extensive Networking and
Communications Capabilities
Enables system monitoring, data logging and adjustability.
Uses open standard MODBUS™ protocol and
Morningstar’s MS View software.
Meterbus: communications between compatible
Morningstar products
Serial RS-232: connection to a personal computer
EIA-485: communications between multiple devices on
a bus
Ethernet: fully web-enabled interface to a local network
or internet; view from a web browser or send email/text
messages
Metering and Data Logging
Optional TriStar meter and remote meter provides
detailed operating data, alarms and faults
Three LED’s display system status
Up to 200 days of data logging via meters or
communications ports
System Status:
53.60V 28C 54.2A
2867W MPPT
Data Logging:
Today Batt
46.4 Vmin
Today Solar
58.9 Amax
Today Solar
107.2 Vmax
Day: -1 Batt
47.2 Vmin
Day: -1 Solar
56.8 Amax
Day: -1 Solar
105.5 Vmax