How to install, operate and maintain your Whole Home Water Filtration System Do not return unit to store If you have any questions or concerns when installing, operating or maintaining your Whole Home Water Filtration System, call our toll free number: 1-888-64 WATER (1-888-649-2837) Monday - Friday, 8 AM - 7 PM EST or visit www.systemsaver.com When you call, please be prepared to provide the model and serial number of your product, located on the rating decal on back of the cover.
TABLE OF CONTENTS Page Specifications & Performance Claims . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Inspect Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications & Performance Claims This system has been tested according to NSF/ANSI 42 for the reduction of chlorine taste and odor. The concentration of the indicated substance in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42. While testing was performed under standard laboratory conditions, actual performance of the system may vary based on local water conditions.
Dimensions 12-1/8" 12-1/8” IN IN 3-3/8" 3-3/8” 13-1/2" 13-1/2” OUT OUT TOP VIEW TOP VIEW IN OUT IN – - OUT 36-1/8” 36-1/8" 27-5/8” 27-5/8" SIDE VIEW SIDE VIEW 4 FRONT VIEW FRONT VIEW Morton® Installation & Operation Manual FIG.
Inspect Shipment The parts required to assemble and install the Whole Home Water Filtration System are included with the unit. Thoroughly check the Whole Home Water Filtration System for possible shipping damage and parts loss. Also inspect and note any damage to the shipping carton. Remove and discard (or recycle) all packing materials. To avoid loss of small parts, we suggest you keep the small parts in the parts bag until you are ready to use them.
Before You Start = Use care when handling the Whole Home Water Filtration System. Do not turn upside down, drop, or set on sharp protrusions. = The Whole Home Water Filtration System has a maximum allowable inlet water pressure of 125 psi and a minimum of 30 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a pressure reducing valve if necessary (Adding a pressure reducing valve may reduce the flow.).
Installation Requirements Location Requirements Consider the following when selecting an installation location for the Whole Home Water Filtration System. = Do not operate the Whole Home Water Filtration System where freezing temperatures occur. Do not attempt to treat water over 120ºF. Freezing temperatures or hot water damage voids the warranty.
Installation Requirements Plumbing Codes Valve Drain Requirements All plumbing must be completed in accordance with national, state and local plumbing codes. Using the flexible drain hose (included), measure and cut to the length needed. Flexible drain hose is not allowed in all localities (check your plumbing codes). If local codes do not allow use of a flexible drain hose, a rigid valve drain run must be used. Purchase a compression fitting (1/4 NPT x 1/2 in.
Installation Requirements Inlet - Outlet Plumbing Options 3 Valve Bypass Always install either a single bypass valve (provided) to the contractor/plumber-supplied plumbing, as shown in Figure 7 OR if desired, a 3 valve bypass system (parts not included) can be installed, as shown in Figure 6. Bypass valves allow you to turn off water to the Whole Home Water Filtration System for maintenance if needed, but still have water in house pipes.
Installation Instructions Step 1. Turn Off Water Supply Level if Necessary 1. Close the main water supply valve, near the well pump or water meter. 2. Open all faucets to drain water from the house pipes. NOTE: Be sure not to drain water from the water heater, as damage to the water heater elements could result. Step 2. Move the Whole Home Water Filtration System into Place 1. Move the Whole Home Water Filtration System into installation position. Set it on a level surface.
Installation Instructions Step 5. Install Valve Drain Hose NOTE: See valve drain options on page 8. 1. Measure, cut to needed length and connect the 3/8" drain line (provided) to the Whole Home Water Filtration System valve drain fitting (See Figure 10). Use a hose clamp to hold the hose in place. Single Bypass Valve Drain Line Connection IMPORTANT: If codes require a rigid drain line see “Valve Drain requirements" section. 2. Run the drain hose or copper tubing to the floor drain. Secure drain hose.
Programming the Whole Home Water Filtration System Display UP button DOWN button PROGRAM button CLEAN button When the power supply is plugged into the electrical outlet, a model code and a test number (example: J2.0), begin to flash in the faceplate display. Then, 12:00 PM and the words “PRESENT TIME" begin to flash. NOTE: If “- - - -” shows in the display, press the r UP or s DOWN button until the model code “CF 8” shows in the display.
Start Up Procedure IMPORTANT: Run the start up cycle immediately after completing installation, before using any water in the home. The filtration media in this Whole Home Water Filtration System contains a small number of harmless activated carbon particles generated during shipping that are small enough to exit the system with water flow. It is normal for these particles to cause a temporary discoloration of the water coming out of the system.
Customizing Features / Options Start a Clean Rinse Cycle Set Length of Clean Rinse To manually start a Clean Rinse cycle, press and hold the CLEAN button for a few seconds, until “RECHARGE NOW” flashes in the display. By default the Whole Home Water Filtration System’s Clean Rinse cycle will consist of a 2 minute backwash followed by a 1 minute fast rinse. This should be sufficient for most applications. FIG.
Customizing Features / Options Operating in Manual Clean Rinse Mode Clean Rinse cycles will run automatically, unless the automatic Clean Rinse function has been disabled. If this function has been disabled, it will be necessary to manually initiate any Clean Rinse cycles. It is recommended that a Clean Rinse cycle should be run at least once each month, or more frequently if necessary. A manual Clean Rinse mode may be used when a drain (required for automatic Clean Rinse) is not available.
Care of Your Whole Home Water Filtration System Vacations and Extended Periods of No Water Use If your Whole Home Water Filtration System will not be used for an extended period of time (several months), please follow one of these recommendations: = If the water supply to the unit is not turned off, and the automatic Clean Rinse function has not been disabled, then no further actions are required.
Troubleshooting PROBLEM CAUSE (NEW SYSTEM) Start up procedure has not been completed Water has black or gray color Low water pressure at house faucets (NOT A NEW SYSTEM) Normal abrasion of filtration media Sediment filter screen is clogged Filtration media pores are blocked Water has objectionable taste and/or odor No water flow to drain during Clean Rinse cycle Clean Rinse cycle does not run automatically Clean Rinse cycle does not run at the programmed time of day Steady beeping from electronic c
Troubleshooting Procedure for removing error code from display: 1. Unplug power supply from electrical outlet. 2. Correct problem. 3. Plug power supply back in. 4. Wait 8 minutes. The error code will return if the problem was not corrected.
Notes Morton® Installation & Operation Manual 19
Whole Home Water Filtration System Exploded View 17 20 19 14 70 71 15 72 Valve Assembly See Pages 22 & 23 for parts 21 72 16 1 5 2 4 3 6 7 8 13 9 10 11 12 20 Morton® Installation & Operation Manual 18
Whole Home Water Filtration System Parts List Key No. Part No. ¢ 7311038 – 7112963 2 á 1 3 á á 4 7077870 6 7105047 5 – 7 8 9 10 11 12 13 14 15 16 7265025 7331177 á á Ù Ù Ù Ù Ù 7310781 7310773 7311020 17 7337482 19 7139999 18 20 7259927 1103200 21 7278434 ¢ 7339955 Description Assembly, Replacement Mineral Tank, w/media & associated components (Includes Key Nos. 1 through 13) Distributor O-Ring Kit (includes Key Nos.
Valve Assembly Exploded View 50 51 52 53 55 54 78 56 57 77 59 60 58 61 66 67 70 62 63 64 74 65 76 68 69 71 75 72 Wear Strip Seal Cross-section View 22 73 Morton® Installation & Operation Manual
Valve Parts List Key No. 50 Part No. 7338111 Screw, #6-19 x 1-3/8” (2 req.) 7337474 Motor Mount 51 7281291 53 7284964 52 54 – 55 56 57 58 59 7030713 7331274 á á á 64 65 á Flow Plug, 3.4 gpm Seal Kit (includes Key Nos. 60-65) O-Ring, 7/16” x 5/8” Rotor Seal á O-Ring, 3/8” x 9/16” á á – 7342665 69 Clip, Drain O-Ring, 3-3/8” x 3-5/8” á 7082087 68 Drain Hose Adaptor Kit (incl. Key Nos.