Product Card

MADE IN ITALY
language
GENERATING SET
GE 4000 KDM
FEATURES
Manual recoil
Sockets 1x 230V 16A 2P+T CEE
1x 230V 16A 2P+T Schuko
Overload thermal shut o
Battery charger 12 Vcc with fuse protection
Protective frame
Portable
Meets EC directives of safety
POWER RATINGS
* Stand-by single-phase power 4 kVA (3.6 kW) / 230V / 17.4 A
* PRP single-phase power 3.7 kVA (3.3 kW) / 230V / 16 A
* COP single-phase power /
Frequency 50 Hz
Cos j 0.9
4-STROKE, DIRECT INJECTION, NATURAL ASPIRATED
Model KOHLER - KD350
* Stand-By net power 4.6 kWm (6.3 hp)
* PRP net power 4.3 kWm (5.8 hp )
* COP net power /
Cylinders/ Displacement 1 / 349 cm³ (0.349 lt)
Bore / Stroke 82 / 66 (mm)
Compression ratio 20.3 : 1
BMEP (Brake Mean Eective
Pressure : LTP - PRP)
/
Speed governor type Mechanical
FUEL CONSUMPTION
110 % (Stand-By power) 260 g/kWh - 1.4 l/h
100 % of PRP
260 g/kWh - 1.3 l/h
75 % of PRP 260 g/kWh - 1 l/h
50 % of PRP 260 g/kWh - 0.6 l/h
COOLING SYSTEM Air
Total system cap. - only engine /
Fan air flow -5 m³/min
LUBRIFICATION SYSTEM
Total oil system capacity /
Oil capacity in sump 1.2 lt.
Oil consumption at full load 0.005 l/h
3000 rpm EnginE
EXHAUST SYSTEM
Maximum exhaust gas flow /
Max. exhaust gas temp. /
Maximum back pressure /
External diameter exhaust pipe /
ELECTRICAL SYSTEM /
Starter motor power /
Battery charging alternator cap. /
Cold star /
Cold start aids /
AIR FILTER Dry
Combustion air flow 0.5 m³/min
HEAT REJECTED AT FULL LOAD
To exhaust system /
To water and oil /
Radiated to room /
To charge cooler /
* Output powers according to ISO 3046-1
* Output powers according to ISO 8528
The images are for reference
05/2017
DEFINITIONS
Valid declared powers up to the followings environmental conditions: temperature
25°C, altitude 100 meters above sea level)
LTP stand-by power: Maximum available power for use with vAirble loads for a yearly
number of hours limited at 500 h. No overload is admitted.
PRP power: Continue power with variable loads. Maximum power for use with variable
loads for a yearly illimited nubers of hours.
COP power: COP Power: continuous power with constant load. Maximum power for use
with constant loads for a yearly unlimited numbers of hours.
pag 1
Air cooling diesel
single-phase manual recoil

Summary of content (3 pages)