User Manual
MADE IN ITALY
language
GE SX-12000 KTDT
• Start and stop engine key
• Low oil pressure warning light with shutdown
• High cooling temperature warning light with shutdown
• Battery charge warning light fault
• Low fuel warning light
• Glow plug light
• Digital multifunction meter : Voltmeter - Frequencymeter - Total Hoursme-
ter - Partial Hoursmeter (resettable) - Battery voltage
• Fuel level gauge
• Emergency stop buttom
• Circuit breaker
• ELCB-GFI (Ground Fault Interruptor)
• Output sockets: 1x 400V 16A 3P+N+T
1x 230V 16A 2P+T
1x 230V 16A Schuko
• Earth terminal (PE)
Pag 2
01/2017
manual Control PanEl
SYNCHRONOUS, THREE-PHASE, SELF-EXCITED, SELF-REGULATED
WITHOUT AVR WITH AVR
Continuos power 11.5 kVA
Stand-by power 12.5 kVA
Three phase voltage 400 Vac
Frequency 50 Hz
Cos j 0.8
Model A.V.R. / HVR 10
Voltage regulation acc. ± 4 % ± 1 %
Sustained short circuit current ≤ 3 In
Transient dip (100% load) < 15 %
Recovery time /
Eciency at 100% load
83 % (400V - Cos j 0.8)
83.5 % (400V - Cos j 0.8)
Insulation Classe H
Connection - Terminals Serie - N°6
Electromagnetic compatibility (
R.F.I. suppr.)
EN55011
Waveform distorsion - THD <4%
Thelephone interference - THF /
altErnator
REACTANCES
(11.5 KVA - 400V)
Direct axis synchronuos - Xd 280 % 239 %
Direct axis transient - X’d 21 % 19 %
Subdirect axis transient - X”d 5.8 % 4.6 %
Quadrature axis synchronuos - Xq 155 % 130 %
Quadr. axis subtransient - X”q /
Negative sequence - X2 /
Zero sequence - X0 /
TIME CONSTANTS
Transient - T’d 0.04 sec 0.046 sec
Subtransient - T”d 0.006sec
Open circuit - T’do 0.53 sec 0.58 sec
Armature - Ta /
Short-circuit ratio Kcc 0.62 0.72
IP protection degree IP 23
Cooling air flow 0.082 m³/sec.
Coupling | Bearing Diretto SAE 5 -7 ½ - N°1
gEnEral SPECifiCationS
Fuel tank capacity 38 lt.
Running time (75% to PRP) 14.5 h
Starter battery 12 Vdc -38Ah
IP protection degree IP 23
* Acoustic power according to European Directive 2000/14/CE
* Measured acoustic power LwA
(pressure LpA)
93 dB(A) (68 dB(A) @ 7m)
* Guaranteed acoustic power LwA
(pressure LpA)
93 dB(A) (68 dB(A) @ 7m)
Performance class (ISO 8528) G2