Product Manual

TF II 9 Y J-4x1000
M
1.5
REV.0-10/13
TECHNICAL DATA
07/10/13 8B972-GB_10-13
I
GB
F
2000 / 14 / CE
Technical data TF II 9 Y J-4x1000
LIGHTS AND MAST Lamp type 4 x 1000W - METAL HALIDE
Mast rotation 340° - MANUAL
Mast TELESCOPIC - 9 m - HYDRAULIC
GENERAL
CHARACTERISTICS
Wind load stability UP TO 80 km/h
Tank capacity 110 l
Running time 75 h (lights load only)
Ip protection IP 44
Acoustic power LwA = 90 dBA LpA = 65 dBA @ 7 m
Stabilizers 4 (2 ADJUSTABLE)
Dimensions (l x w x h)
(mm)
Fully deployed (working conditions)
a) NO TRAILER 2210 x 1885 x 9000
b) SITE TOW 3150 x 1885 x 9000
c) ROAD TRAILER 3150 x 1885 x 9000
Transport conditions
d) NO TRAILER 1745 x 1325 x 2050
e) SITE TOW 3150 x 1325 x 2250
f) ROAD TRAILER 3135 x 1400 x 2250
Weight (dry) a) NO TRAILER 940 kg
b) SITE TOW 1060 kg
c) ROAD TRAILER 1075 kg
Tyres • SITE TOW 2 x 185 / 65 R 14
• ROAD TRAILER 2 x 195 / 50 R 13
ENGINE Model YANMAR 3TNV76
Net power (st-by / prp) 9 kW / 8.2 kW @ 1500 rpm
Cylinders / displacement 3 / 1116 cm
3
Fuel consumption 1.5 l / h (lights only); 2.4 l / h (PRP)
Battery 12V 45 Ah
GENERATOR Alternator LINZ E1C13SC/4 - 8 kVA, SINGLE PHASE, SYNCHRONOUS, BRUSHLESS, 4 POLES PF =
0.9 ISOLATION CLASS = H
Output power 3.5 kVA 230 V / 15.2 A 50 Hz 1x16 A / 230 V 2P+T CEE
CONTROL PANEL EP6 controller
Functions:
Starter key
Autostart
• Protections and alarms High temperature engine shut down; Low oil pressure shut down; Overspeed shut down; Battery
charge failure shut down; Delayed (5 min.) low fuel shut down; Overvoltage shut down; Battery
over / undervoltage alarm.
Measurements Hourmeter; r.p.m. meter; battery charge alternator voltage; battery voltage; generator voltage;
generator current; generator frequency.
Fuel level gauge - Emergency stop button - Siren - General protection circuit breaker - Output socket protection cir-
cuit breaker - Individual circuit breaker switches for the lamps - Mast up / down push buttons - External power supply
socket (230 V / 32 A 2P+T) and switch (optional).
OUTPUT
Declared power according to ISO 8528-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
(*Stand-by) = maximum available power for use at variable loads for a yearly number of hours limited at 500 h. No overload is admitted.
(**Prime power PRP) = maximum available power for use at variable loads for a yearly illimited number of hours. The average power to be taken during a
period of 24 h must not be over 80% of the PRP.
It’s admitted overload of 10% each hour every 12 h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ACOUSTIC POWER LEVEL
ATTENTION: The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-user and under his direct
responsibility to make a correct evaluation of the same risk and to adopt specic precautions (for instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level (L
wA) - Measure Unit dB(A): it stands for acoustic noise released in a certain delay of time. This is not submitted to the distance of
measurement.
Acoustic Pressure (Lp) - Measure Unit dB(A): it measures the pressure originated by sound waves emission. Its value changes in proportion to the distance
of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level (L
wA) of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A) Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A) Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
PLEASE NOTE: the symbol when with acoustic noise values, indicates that the device respects noise emission limits according to 2000/14/CE directive.