User's Manual

2. System Description 2-4
© 2012 Moseley, Inc. All Rights Reserved. 602-16620-01, Rev. A
o 64 kbps synchronous RS422
Adaptive Power Control
Standard high-power feature at antenna port
o 5W (37 dBm in QPSK mode) in 2 GHz bands
o 1W (30 dBm) in 5.8, 7, and 13 GHz bands
Built-in Network Management System (NMS)
Consecutive Point ring architecture
Built-in Bit Error Rate (BER) performance monitoring
Integrated Crosspoint switch: allows a total of 191 E1s (200 T1s) to be mapped any-
to-any between front-panel ports and RF link(s)
Optional STM-1 Mux/Demux: allows the SDIDU to extract up to 63 E1 (or 84 T1) from
an STM-1. In conjunction with an integrated Crosspoint Switch, up to 223 E1 (284
T1s) can be mapped any-to-any between ports, STM-1, and RF link(s).
2.3 Physical Description
The following sections describe the physical features of EVENT 5800 digital radios.
2.3.1 Back Panel
The following illustration shows the general format of a EVENT 5800 back panel.
Figure 2-3. Transceiver Back Panel
This illustration shows the back panel of a transceiver unit that can be configured as a
transmitter or receiver. The following illustration shows the back panel of a receiver-only
unit.
Figure 2-4. Receiver-Only Back Panel
Note that the back panel of a EVENT 5800 unit will be slightly different depending on the
number and type of hardware modules installed. Some modules are standard and
included in all units. Optional modules may be ordered and installed to support specific
functional requirements.
2.3.2 Hardware Modules
The lower section of the EVENT 5800 chassis is comprised of hardware modules. The
number and type of modules depends on the type and required functionality. A maximum
of eight of modules can be installed in the chassis. A minimum of five modules are
required in a basic EVENT 5800 configured for 1+0 operation. They are:
Power Supply Module
Controller Module
Modem & I/F Telemetry Module
Master I/O Module
Mini I/O Module