User's Manual

2. System Description 2-6
© 2012 Moseley, Inc. All Rights Reserved. 602-16620-01, Rev. A
Master I/O Expansion I/O E1/T1
42xE1/T1 Master I/O 21xE1 Expansion I/O 63xE1/T1
Includes 1-155 Mbps Fast Ethernet
GigE Master I/O None 2xE1/T1 Includes 1-300 Mbps Gigabit Ethernet
GigE Master I/O 16xE1 Expansion I/O 18xE1/T1
Includes 1-300 Mbps Gigabit Ethernet
GigE Master I/O 21xE1 Expansion I/O 23xE1/T1
Includes 1-300 Mbps Gigabit Ethernet
All modules are inserted from the back panel of the chassis. All modules are hot
swappable. The modularity allows for future upgrades via new hardware modules
without a full replacement of a complete chassis. In addition, repair and maintenance
costs are minimized since individual modules can be repaired or replaced.
2.3.3 Back Panel Connectors
The following illustration shows EVENT 5800 back panel connector locations in a typical,
basic unit.
2.3.3.1 Power Supply Module Connector
-48V Power Input: -48V (Non-isolated Input); 2-pin captive power connector. EVENT
5800 requires an input of -48 Volts DC ±10% at the back panel DC Input connector. The
total required power depends on the option cards and protection configuration (1+0,
1+1). Back panel power connector pins are numbered 1-2, from left to right, when facing
the unit back panel. Pin 1 is the power supply return and is connected to chassis ground
internally. Pin 2 should be supplied with a nominal -48V DC, with respect to the unit
chassis (ground). A ground-isolated supply may be used, provided it will tolerate
grounding of its most positive output.
The recommended power input is -44 to -52V DC at 2 Amps minimum. Any power supply
used must be able to supply a minimum of 125 W to the EVENT 5800.
A mating power cable connector is supplied with EVENT 5800. It is a 2-pin plug, 5 mm
pitch, manufactured by Phoenix Contact, P/N 17 86 83 1 (connector type MSTB 2, 5/2-
STF). This connector has screw clamp terminals that accommodate 24 AWG to 12 AWG
wire. The power cable wire should be selected to provide the appropriate current with
minimal voltage drop, based on the power supply voltage and length of cable required.
The recommended wire size for power cables under 10 feet in length supplying -48V DC
is 18 AWG, minimum.
EVENT 5800 unit does not have a power on/off switch. When DC power is connected to
the unit, the digital radio powers up and is operational. There can be up to 5 W of RF
power present at the antenna port. The antenna should be directed safely when power is
applied. The EVENT 5800 is normally supplied with an external power supply that has an
on/off switch.
2.3.3.2 Controller Module Connectors
The following illustration shows the connectors on the Controller Module: