User's Manual

4. Installation 4-2
© 2012 Moseley, Inc. All Rights Reserved. 602-16620-01, Rev. A
connected in an operational configuration, no errors should be reported on the back
panel.
Remote (HT)
192.168.1.113
(8) N-Type
Cable
(11) N-Type
Cable
(14) TNC
Cable
(7) TNC
Cable
EUT (LT)
192.168.1.112
(4) Laptop PC
192.168.1.14
(5) RJ45
Cable, 4m
-48Vdc
Power
Supply
Bench Setup for FDD Link Operation
Event 5800
Green
when
locked
For monitoring radios, open
browser with address
192.168.1.112 for EUT,
192.168.1.113 for remote unit.
Username: factory
Password: arct1c
Green
when
locked
(1) ODU
(2) IDU
(10) Panel
Antenna
(13) IDU
(6) RJ45
Cable, 4m
(3) Pwr Cable/
Pwr Supply
Assy
(9) Panel
Antenna
-48Vdc
Power
Supply
(19) Pwr
Cable/Pwr
Supply Assy
(12) ODU
Notes:
1. Must have Sun Java installed.
2. May have to enter same username/factory for
Java security.
3. Computer not necessary for radio to run
4. Computer may be plugged into NMS at either
end to monitor both radios.
Figure 4-1. Back-to-Back Testing Configuration
4.5 EVENT 5800 Installations
A EVENT 5800 can be installed on a tabletop or cabinet or rack mount. The site must
provide appropriate power. The EVENT 5800 should be: