User's Manual
Table Of Contents
- 1.Safety Precautions
- 2.System Description
- 2.1About This Manual
- 2.2Introduction
- 2.3System Features
- 2.4Physical Description
- 2.5System Description
- 2.6Consecutive Point Architecture
- 2.72 + 0 (East-West) Configuration
- 2.8Spanning Tree Protocol (STP)
- 2.91+1 Protection
- 2.101 + 1 Multi-hop Repeater Configuration
- 2.11Data Interfaces
- 2.12Crosspoint Switch
- 2.13Power Management
- 2.14Event-HD Software and Network Management
- 2.15System Loopbacks
- 3.Installation
- 3.1Unpacking
- 3.2Notices
- 3.3PRE-INSTALLATION NOTES
- 3.4Back-to-Back Bench Testing
- 3.5Overview of Installation and Testing Process
- 3.6Site Evaluation
- 3.7Installation of the Event-HD
- 3.8Quick Start Guide
- 3.9SDIDU™ Service
- 4.Summary Specification
- 5.Rear Panel Connectors
- 5.1DC Input (Power) Connector
- 5.2Ethernet 100BaseTX Payload Connector 1-2
- 5.3SONET Payload Connector
- 5.4STM-1 Payload Connector
- 5.5DVB/ASI, DS-3, E-3, STS-1 Payload Connector
- 5.6NMS 10/100BaseTX Connector 1-2
- 5.7Alarm/Serial Port Connector
- 5.8ODU Connector
- 5.9T1/E1 - Channels 1-2 Connector
- 5.10T1/E1 - Channels 3-16 Connector
- 5.11USB
- 5.12Voice Order Wire
- 5.13Data Order Wire
- 6.Appendix
22 3. Installation
Figure 3-15. Completed Mounting for the Event ODU5800
3.7.3Routing the ODU/IDU Interconnect Cable
1. Select where the cable will enter the truck or building from outside.
2. Determine the length of cable required. Allow three extra feet on each end to allow
for strain relief, as well as any bends and turns.
3. Route the cable.
The SDIDU
TM
is equipped with TNC female connector on the rear of the chassis.
Depending on the ODU type, it will be equipped with either an N-type or TNC female
connector at its interconnecting port. A length of coaxial cable (such as Times Microwave
Systems LMR-400, LMR-300 or LMR-200) fitted with the appropriate N-type or TNC male
connectors is required to connect the ODU to the SDIDU
TM
. This cable assembly may be
supplied in fixed lengths with the digital radio. Bulk coaxial cable of equivalent
specification may also be used, with terminating connectors applied during cable
installation.
Based on an evaluation of the cable routing path, pull the ODU/SDIDU
TM
Interconnect
cable from one unit to the other, utilizing cable trays, ducts, or conduit as required. Take
care that the ODU/ SDIDU
TM
Interconnect cable is not kinked or damaged in any way
during installation. Be sure to protect the TNC connectors from stress, damage and
contamination during installation (do not pull the cable by the connectors). If multiple
ODU/ SDIDU
TM
Interconnect cables are to be installed along the same route, the cables
should all be pulled at one time. Be sure the installed cable does not have any bends that
exceed the specified cable bend radius. The ODU/ SDIDU
TM
Interconnect cable should be
adequately supported on horizontal runs and should be restrained by hangers or ties on