3. Installation 27
per step 2 above. Refer to Figure 3-17. Note that the Software Defined IDU™
SDIDU
TM
does not have a power on/off switch. When DC power is connected, the
digital radio powers up and is operational. There can be up to 5 W of RF power
present at the antenna port. The antenna should be directed safely when power is
applied.
6. Turn on the 48 V dc power supply, and verify that the reading on the digital voltmeter
is as specified in step 3 above.
7. Connect the SDIDU
TM
to the laptop computer, using a Cat-5 Ethernet cable or connect
the SDIDU
TM
to a computer network, using a Cat-5 Ethernet cable. Connect the
Ethernet cable to the NMS 1 or 2 connector on the SDIDU
TM
rear panel. Refer to
Figure 3-18 for the SDIDU
TM
rear panel connections.
NMS
Controller
Ethernet
-48V Power
Input
100Base-T
Ethernet
Data
Channels
ASI
Output
ASI
Input
ODU IF
Connection
Redundant
Power-Supply
(optional for
1+1, 2+0)
ALARM/Serial
Interface
Redundant
MODEM
(optional for
1+1, 2+0)
USB
Ground
lug
Call
Button
Voice
Orderwire
Data
Orderwire
2xT1/E1
14xT1/E1
Ground
lug
Figure 3-18. Software Defined IDU™-SB, 1+1 Protection, Rear Panel
Connections
3.8.5SDIDU™ Configuration
Although basic configuration of the Event-HD SDIDU
TM
does not require a connection to
the ODU, it is recommended that the ODU and SDIDU
TM
are connected prior to
configuring the SDIDU
TM
. A connection to the ODU must be established prior to running
the Link Configuration process (section 5.2) in order to configure ODU related
parameters.
Using the site attributes identified in the site assessment or equivalent configuration
information, configure each IDU by completing the following procedures:
- Setting the SDIDU
TM
IP Address and Network Parameters
- Configuring the SDIDU
TM
- Setting the SDIDU
TM
Device Information