User's Manual
Table Of Contents
- 1.Safety Precautions
- 2.System Description
- 2.1About This Manual
- 2.2Introduction
- 2.3System Features
- 2.4Physical Description
- 2.5System Description
- 2.6Consecutive Point Architecture
- 2.72 + 0 (East-West) Configuration
- 2.8Spanning Tree Protocol (STP)
- 2.91+1 Protection
- 2.101 + 1 Multi-hop Repeater Configuration
- 2.11Data Interfaces
- 2.12Crosspoint Switch
- 2.13Power Management
- 2.14Event-HD Software and Network Management
- 2.15System Loopbacks
- 3.Installation
- 3.1Unpacking
- 3.2Notices
- 3.3PRE-INSTALLATION NOTES
- 3.4Back-to-Back Bench Testing
- 3.5Overview of Installation and Testing Process
- 3.6Site Evaluation
- 3.7Installation of the Event-HD
- 3.8Quick Start Guide
- 3.9SDIDU™ Service
- 4.Summary Specification
- 5.Rear Panel Connectors
- 5.1DC Input (Power) Connector
- 5.2Ethernet 100BaseTX Payload Connector 1-2
- 5.3SONET Payload Connector
- 5.4STM-1 Payload Connector
- 5.5DVB/ASI, DS-3, E-3, STS-1 Payload Connector
- 5.6NMS 10/100BaseTX Connector 1-2
- 5.7Alarm/Serial Port Connector
- 5.8ODU Connector
- 5.9T1/E1 - Channels 1-2 Connector
- 5.10T1/E1 - Channels 3-16 Connector
- 5.11USB
- 5.12Voice Order Wire
- 5.13Data Order Wire
- 6.Appendix
6. Appendix 7
7
Alarm
Affected
Component
Description
LED to
RED
Alarm
Code
Severity
East ATPC Tx at
Max Power
ODU The IDU is unable to increase
the Tx Power as requested by
link partner due to maximum
power being reached.
Maximum power is specified in
the configuration table.
N/A 76 Info
West ATPC Tx at
Max Power
ODU The IDU is unable to increase
the Tx Power as requested by
link partner due to maximum
power being reached.
Maximum power is specified in
the configuration table.
N/A 78 Info
Link Fault IDU Failed to receive link heartbeat
from link partner via Radio
Overhead (ROH) channel.
Fault detection via timeout
counter, which is reset via
reception of link heartbeat
message.
N/A 81 Critical
Remote Fault IDU Link Partner IDU indicating it
has a fault condition. Local
IDU receives Link Partner
Fault detection via Radio
Overhead (ROH) channel
message.
N/A 82 Info
Encryption
Failure
IDU Data is not being decrypted
properly due to encryption key
mismatch between link
partners. Fault detection via
software detection of
unreadable ROH messages
from link partner.
N/A 83 Critical
Encryption
OneWay
IDU Only one IDU has data
encryption enabled. Fault
detection via software
messages to/from link
partner.
N/A 84 Major
External
Alarm 1
External The external Alarm 1 input
has been activated. Fault
detection via polling GPIO.
Polling interval 1 sec.
N/A 91 Info
External
Alarm 2
External The external Alarm 2 input
has been activated. Fault
detection via polling GPIO.
Polling interval 1 sec.
N/A 92 Info