Specifications

5.Charging abnormal(battery over charing, or over discharging)
Battery is dead
Battery malfunction
poor connection
red cable disconncet
voltage rectifier
malfunction
while cable disconnect
defective coil
poor connection
charging abnormal(over charging) A.C. generators
white cable
disconnect
cable poor connection
poor connection of
green cable
Voltage rectifier
faulty
Check and adjust Trouble condition
The reason
Measure batters
Voltage then start
engine
Voltage re main
The Same
Voltage goes up
To normal value,
But after engine
Stop ,the Voltage
Goes down again
Check voltage rectifier
Plug is loose or not
good
loose
Check the voltage
Between chassis Θand
The red cable of
Voltage rectifier
Check the resistivity
Of A .C . generator coil
normal
abnormal
Start engine, connect
Green cable to
Chassis, then measure
The voltage between
Chassis Θ
and red cable
of voltage of
rectifier.
Voltage higher
Than specification
Voltage normal
Check the connection
Of the cable of
Voltage rectifier
good Poor connection
Check the resistivity
Of the body of
Voltage rectifier
Out of spec
good
No voltage