Datasheet

www.symcom.com • 800-843-8848 • fax: 605-348-5685
10
Features:
Optical isolation from line potentials
Powered by the 77x product
RS-485 compliant bus drive capability
Remote reset input connection
Power connection for the Model RM-1000
Approvals:
Available Models:
Specications
RS485MS-2W
The RS485MS-2W
is required to enable the Modbus communications
function on Model 77x-type products. This module
is required when the RM-1000, RM-2000 or other
Modbus capable device is used with 77x-type
products.
For more information see:
See Appendix A, page 66, Figure 2 for dimensional
drawing.
Functional Specications
Remote Reset (for use with optional 777 Series) ...Normally open pushbutton rated 24VDC,
10mA (min.)
General Characteristics
Ambient Operating Temperature ...............
-20° to 50°C (-4° to 122°F)
Terminal (depluggable terminal block)
Torque ......................................3 in.-lbs. (max.)
Wire AWG ...................................12-20 AWG
Class of Protection ............................IP20
Relative Humidity ............................10-95%, non-condensing per IEC 68-2-3
Standards Passed
Electrostatic Discharge (ESD) ...................IEC 61000-4-2, Level 3, 6kV contact, 8kV air
Radio Frequency Immunity, Radiated ...........150 MHz, 10V/m
Fast Transient Burst ...........................IEC 61000-4-4, Level 3, 4kV input power
Hi-Potential Test ..............................Meets UL508 (2 x rated V + 1000V
for 1 min)
Surge
Input Power .................................IEC 61000-4-5, Level 1
Inputs/Data Lines ............................IEC 61000-4-5, Level 2
Safety Marks
UL ..........................................UL508 (File #E68520)
CE ..........................................IEC 60947
Enclosure ....................................Polycarbonate
Dimensions ..................................2.08”H x 2.90”W x 0.77”D
Weight ......................................0.26 lb. (4.16oz., 117.93 g)
Mounting Method ............................9-pin D-Sub connector on the side
of a 777-Series
Features:
Can be used in both new and existing
installations
Can be used as stand-alone or with a
777 Plus series unit
Can be re-configured to work with standard
777 units
Reduced field wiring. Unpluggable
terminal block connection for network.
Ease in system startup and commissioning
Compact size
DIN rail or surface mountable
Additional remote reset input to reset
777 Plus series
Flexible addressing standard
Approvals:
Available Models:
Specications
CIO-MB
CIO-120-MB
The CIO-MB / CIO-120-MB Modules
are convenient and cost-effective Modbus-RTU
interfaces capable of providing discrete control and
monitoring of an overload relay over a Modbus
network.
For more information see:
See Appendix A, page 66, Figure 3 for dimensional
drawing.
Functional Specications
Remote Reset (for use with optional 777 Series) ....Normally open pushbutton rated 24VDC,
10mA (min.)
Power Requirements
Voltage ....................................... 24VDC +10%
Current ....................................... 95mA (max.) 70mA (typical)
Power ........................................2.28 W (max.) 1.7 W (typical)
Ethernet Controller ............................IEEE 802.3
Capability ....................................10Base-T
Input Characteristics
General Purpose (4)
Voltage Range
CIO-MB ......................................12-24VDC
CIO-120-MB ..................................90-130VAC
Current ....................................... 2mA (typical)
Output Characteristics
SPDT (1), SPST (1)
Pilot Duty ....................................480VA & 240VAC, B300
General Purpose ...............................5A @ 240VAC
General Characteristics
Ambient Operating Temperature ................
-20° to 70°C (-4° to 158°F)
Terminal (depluggable terminal block)
Torque .......................................3 in.-lbs. (max.)
Wire AWG ....................................12-20 AWG
Class of Protection .............................IP20, NEMA 1 (nger safe)
Relative Humidity .............................10-95%, non-condensing per IEC 68-2-3
Standards Passed
Electrostatic Discharge (ESD) ....................IEC 61000-4-2, Level 3, 6kV contact, 8kV air
Radio Frequency Immunity, Radiated ............150 MHz, 10V/m
Fast Transient Burst ............................IEC 61000-4-4, Level 3, 4kV input power
Hi-Potential Test ...............................Meets UL508 (2 x rated V + 1000V for 1 min)
Surge
Input Power ..................................IEC 61000-4-5, Level 1
Inputs/Data Lines .............................IEC 61000-4-5, Level 2
Safety Marks
UL ..........................................UL508 (File #E68520)
CSA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C22.2 (File #46510)
CE ..........................................IEC 60947-6-2
Enclosure .....................................Polycarbonate
Dimensions ...................................2.08”H x 2.776”W x 0.77”D
Weight .......................................0.25 lb. (4 oz., 113.4 g)
Mounting Methods .......................... DIN Rail or surface mount (w/ two #8
screws)
Communication Modules
Communication Adapters
RS485-RS232 converter with cable & plug
RS485-USB converter with cable & plug/
RS232:USB converter
Models RS485MS-2W / CIO-MB
communication link to PLC/SCADA/monitoring systems
Specications match industry standard.
CATALOG_SYMCOM_2014.indd 10 6/10/14 11:06 AM