Datasheet
www.symcom.com • 800-843-8848 • fax: 605-348-5685
11
Features:
• Can be used in both new and existing
installations
• Can be used as stand-alone or with a 777
Plus series unit
• Reduced field wiring. Unpluggable terminal
block connection for network.
• Ease in system startup and commissioning
• Compact size
• DIN rail or surface mountable
• Additional remote reset input to reset 777
Plus series
• Flexible addressing standard
Approvals:
Specications
CIO-DN-P
CIO-120-DN-P
Features:
• Can be used in both new and existing
installations
• Can be used as stand-alone or with a 777
Plus series unit
• Reduced field wiring. Simple 9-Pin sub-D
connection for network
• Ease in system startup and commissioning
• Compact size
• DIN rail or surface mountable
• Additional remote reset input to reset 777
Plus series
• Flexible addressing standard
Approvals:
Available Models:
Specications
CIO-777-PR
Available Models:
The CIO-777-PR Module
is a convenient and cost-effective Profibus
interface capable of providing discrete control
and monitoring of motor starters, drives and other
devices over a Profibus network.
For more information see:
See Appendix A, page 66, Figure 3 for dimensional
drawing.
The CIO-DN-P / CIO-120-DN-P
are convenient and cost-effective Devicenet™
interfaces capable of providing discrete control
and monitoring of motor starters, drives and other
devices over a Devicenet™ network.
For more information see:
See Appendix A, page 66, Figure 3 for dimensional
drawing.
Input Characteristics
Power Requirements
Voltage (nominal). . . . . . . . . . . . . . . . . . . . . . . . 24VDC
Current ................................. 137mA (max.)
Power .................................. 3.28 W (max.)
Digital Inputs
Voltage Range
CIO-DN-P .............................. 12-24 VAC
CIO-120-DN-P .......................... 90-130VAC
Frequency .............................. 50/60Hz
Maximum Current ....................... 2mA (typical)
Remote Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24VDC, 10mA (min.), NO pushbutton
Output Characteristics
Form A & Form C Contactors
Pilot Duty .............................. 480VA @ 240VAC, B300
General Purpose ......................... 5A @ 240VAC
General Characteristics
Temperature Range ...................... -20
o
to 70
o
C (-4
o
to 158
o
F)
Relative Humidity .........................10-95%, non-condensing
Wire Gauge ...............................Solid or stranded, 12-20 AWG
Terminal Torque ...........................3 in.-lbs.
Hi-Potential Test (relays to other circuits) .....(2 x rated V + 1000V for 1 minute)
EMC Standards
Electrostatic Discharge (ESD) ................IEC 61000-4-2, Level 3, 6kV contact, 8kV air
Radio Frequency Immunity, Radiated ........150 MHz, 10V/m
Fast Transient Burst ........................IEC 61000-4-4, Level 3, 4kV input power
Safety Marks
UL, ULC Listed ............................UL508 (File #E68520)
CSA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C22.2 (File #46510)
Enclosure .................................Polycarbonate
Dimensions ...............................3.4” H x 1” W x 5” D (w/ depluggable
connectors)
Weight ...................................0.25 lb. (4 oz., 113.4 g) (w/ depluggable
connectors)
Mounting Methods ........................DIN Rail or surface mount (w/ two #8 screws)
Input Characteristics
Power Requirements
Voltage (nominal). . . . . . . . . . . . . . . . . . . . . . . . 12-24VDC
Current ................................. 150mA (max.)
Power .................................. 3.6 W (max.)
Digital Inputs
Voltage Range ........................... 12-24VAC
Maximum Current ....................... 2mA (typical)
Remote Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24VDC, 10mA, (min.), NO pushbutton
Output Characteristics
Form A & Form C Contactors
Pilot Duty .............................. 480VA @ 240VAC, B300
General Purpose ......................... 5A @ 240VAC
General Characteristics
Ambient Temperature Range
Operating .............................. -20
o
to 70
o
C (-4
o
to 158
o
F)
Storage ................................. -40
o
to 80
o
C (-40
o
to 176
o
F)
Relative Humidity .........................10-95%, non-condensing per IEC 68-2-3
Wire Gauge ...............................Solid or stranded, 12-20 AWG
Terminal Torque ...........................3 in.-lbs.
Hi-Potential Test (relays to other circuits) .....Meets UL508 (2 x rated V + 1000V for 1 min.)
EMC Standards
Electrostatic Discharge (ESD) ................IEC 61000-4-2, Level 3, 6kV contact, 8kV air
Radio Frequency Immunity, Radiated ........150 MHz, 10V/m
Fast Transient Burst ........................IEC 61000-4-4, Level 3, 4kV input power
Safety Marks
UL, ULC Listed ............................UL508 (File #E68520)
CSA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C22.2 (File #46510)
Enclosure .................................Polycarbonate
Dimensions ...............................3.4” H x 1” W x 5” D (w/ depluggable
connectors)
Weight ...................................0.25 lb. (4 oz., 113.4 g) (w/ depluggable
connectors)
Mounting Methods ........................DIN Rail or surface mount (w/ two #8 screws)
Communication Modules
Models CIO-DN-P / CIO-777-PR
communication link to PLC/SCADA/monitoring systems
CATALOG_SYMCOM_2014.indd 11 6/10/14 11:06 AM