Datasheet

www.symcom.com • 800-843-8848 • fax: 605-348-5685
23
Available Models:
Features:
Quick mounting with single screw
Small package, ideal for assembly into
panels
Standard ¼” quick connects
Adjustable restart delay
A
pprovals:
202
202-RP
202-575-RP
Specications
The Model 202
is a 3-phase, auto-ranging, dual-range voltage
monitor that protects 190-480VAC, 50*/60Hz
motors regardless of size. The product provides
a user selectable nominal voltage setpoint and the
voltage monitor automatically selects between the
200V and 400V range.
This unique microcontroller-based voltage and
phase-sensing device constantly monitors the
3-phase voltages to detect harmful power line
conditions. When a harmful condition is detected,
the MotorSaver’s output relay is deactivated after
a specified trip delay. The output relay reactivates
after power line conditions return to acceptable
levels. The Model 202 includes advanced single
LED diagnostics. Five different light patterns
distinguish between faults and normal conditions.
The Model 202-RP
monitors the phase rotation of 3-phase systems and
trips on reverse phase only. Critical applications
include fan motors, scroll compressors, grinders,
conveyor systems, elevators and escalators. The
status light turns green and the relay is activated
when rotation is correct.
For more information see:
See Appendix A, page 68, Figure 9 for dimensional
drawing.
See Appendix B, page 74, Figures 17 & 18 for typical
wiring diagrams.
Model 202 / 202-RP
3-phase voltage/phase monitor, panel mount, adjustable or manual restart delay
(-RP reverse-phase protection only)
3-Phase Voltage Monitor
General Characteristics
Temperature Range .............................-40° to 70°C (-40° to 158°F)
Trip & Reset Accuracy ..........................±1%
Repeatability ...................................±0.5%
Maximum Input Power .........................5 W
Relative Humidity ..............................95%, non-condensing
Transient Protection ............................IEC 61000-4-5, ±4kV
Input to Output Dielectric .......................1960 Vrms min.
Termination ....................................0.25” male quick connect
Safety Marks
UL ............................................UL508 (File #E68520)
Dimensions ....................................2.5” H x 2.5” W x 1.4” D
(63.5 x 63.5 x 35.56mm)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.5 lb. (8 oz., 226.8 g)
Mounting Method ..............................1/4” socket head cap screw
(customer supplied)
*Note: 50Hz will increase all delay timers by 20%.
CE Pending
Input Characteristics
Line Voltage
202, 202-RP ....................................190-480VAC
202-575-RP .....................................475-600VAC
Frequency .....................................50*/60Hz
Functional Characteristics
Phase Sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ABC
Low Voltage (% of setpoint)
Trip ...........................................90%
Reset ..........................................93%
High Voltage (% of setpoint)
Trip ...........................................110%
Reset ..........................................107%
Voltage Unbalance (NEMA)
Trip ...........................................6%
Reset ..........................................4.5%
Trip Delay Time
High and Low Voltage ..........................4 seconds
Unbalance & Phasing Faults .....................2 seconds
Restart Delay Time
After a Fault ...................................Manual, 2-300 seconds adj.
After a Complete Power Loss ....................Manual, 2-300 seconds adj.
Output Characteristics
Output Contact Rating (SPDT)
Pilot Duty .....................................480VA @ 240VAC
General Purpose ................................10A @ 240
VAC