Datasheet
www.symcom.com • 800-843-8848 • fax: 605-348-5685
32
Available Models:
Features:
• Protects against low voltage
• Optional
• High voltage protection
• Variable restart delay
• Variable trip delay
A
pprovals:
Specications
50R-100
50R-100-2
50R-200
50R-200-2
50R-200-3
50R-200-2-9
50R-400
50R-400-2
50R-400-3
50R-400-2-9
The Model 50R
single-phase voltage monitor has a voltage-sensing
circuit which constantly monitors the single-phase
power for a low voltage condition. Single-phase
motors on fans, compressors, air conditioners,
heat pumps, well pumps, sump pumps and small
conveyor motors are all applicable to the Model 50R.
When a harmful condition is detected, the
MotorSaver’s output relay is deactivated after a
specified trip delay. The output relay reactivates
after power line conditions return to an acceptable
level and a specified amount of time has elapsed
(restart delay). The trip delay prevents nuisance
tripping due to rapidly fluctuating power line
conditions.
For more information see:
See Appendix A, page 68, Figure 7 for dimensional
drawing.
See Appendix B, page 76, Figure 28 for typical
wiring diagrams.
Options
2 - Variable Restart Delay (Manual, 2-300 seconds)
3 - Variable Trip Delay (2-30 seconds)
9 - High Voltage Detection
Model 50R
single-phase voltage monitor, panel mount, optional high voltage, variable restart or trip delay
Single-Phase Voltage Monitor
General Characteristics
Ambient Temperature Range
Operating .....................................-20° to 70°C (-4° to 158°F)
Storage ........................................-40° to 80°C (-40° to 176°F)
Maximum Input Power ..........................5 W
Relative Humidity ..............................10-95%, non-condensing per IEC 68-2-3
Terminal
Torque ........................................7 in.-lbs.
Wire Size ......................................12-18AWG
Electrostatic Discharge (ESD) .....................IEC 61000-4-2, Level 3, 6kV contact, 8kV air
Fast Transient Burst .............................IEC 61000-4-4, Level 3, 3.5kV input
power and controls
Transient Protection (Internal) ....................IEC 61000-4-5; 1995 ±6kV
Safety Marks
UL ............................................UL508 (File #E68520)
CE ............................................IEC 60947-6-2
Dimensions ....................................2.93”H x 5.27”W x 2.95”D
(74.4 x 133.9 x 74.9mm)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.98 lb. (15.68 oz., 444.52 g)
Mounting Method ..............................#8 screws
Special Options
Option 2 - Variable Restart Delay .................Manual, 2-300 seconds
Option 3 - Variable Trip Delay ...................2-30 seconds
Option 9 - High Voltage Detection Operating Points
Trip (% of Setpoint) .............................110%
Reset (% of Setpoint) ............................107%
*Note: 50Hz will increase all delay timers by 20%
Input Characteristics
Line Voltage
50R-100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95-120VAC
50R-200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190-240VAC
50R-400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .380-480VAC
Frequency .....................................50*/60Hz
Functional Characteristics
Low Voltage
Trip (% of setpoint) .............................90%
Reset (% of setpoint) ............................93%
Delay Time (Nominal)
Trip ...........................................4 seconds
Restart (low voltage) ............................2 seconds
Restart (complete power loss) ....................2 seconds
Output Characteristics
Output Contact Rating (SPDT - 1 Form C)
50R-100, 50R-200
Pilot Duty .....................................480VA @ 240VAC
General Purpose. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10A @ 240VAC
50R-400
Pilot Duty .....................................470VA @ 600VAC
CATALOG_SYMCOM_2014.indd 32 6/10/14 11:06 AM