NOTE: Vessels using 12‑volt trolling motors with multiple batteries must have
a common ground bonding circuit. Not establishing a common ground
between the vessel batteries may cause severe corrosion, electrolysis, or
electrical shock.
NOTE: The common ground bond cable should be no more than one wire size
(gauge) smaller than the battery cables, nor smaller than 16‑gauge (AWG).
The common ground bond cable must be insulated, and secured to the
negative (–) battery terminals with ring‑style connectors.
6. Starting with the positive (+) lead, reconnect the battery cables to the
engine starting battery.
12-volt battery connection with common ground bond
a - Power cables to trolling motor
b - Manual reset circuit breaker
c - Trolling motor battery
d - Engine starting battery
e - Power cables to engine
f - Common ground (–) bond cable
24-VOLT BATTERY CONNECTION
1. Starting with the negative (–) lead, disconnect the battery cables from the
engine starting battery.
2. Install a 50‑amp (good) or 60‑amp (best) manual reset circuit breaker in
line with the trolling motor power cable positive (+) lead and the trolling
motor battery B positive (+) terminal.
3. Connect the positive (+) trolling motor lead to the positive (+) terminal on
trolling motor battery B.
4. Connect a jumper wire (reference gray) between the negative (–) terminal
on battery B to the positive (+) terminal on battery A.
RED
BLK
BLK
REDRED
a
b
c
d
e
44291
f
PRODUCT INSTALLATION, WIRING, AND BATTERY
INFORMATION