13 If no further testing is needed, place the base radio in Normal Mode, as follows:
a Click Change to Normal Mode.
b At the confirmation screen, click OK.
The base radio halts activity in the current mode and switches operation to the requested
mode.
5.12.4
Measuring HPD Base Radio Rx Sensitivity and Rx BER
When and where to use:
Follow this procedure to test:
Rx Sensitivity: Does the 1% Bit Error Rate (BER) meet specifications for your High Performance
Data (HPD) GTR 8000 Base Radio configuration?
Rx BER: Does -70 dBm produce a 0.01% BER or better, as expected?
Procedure:
1 Perform the service monitor setup steps in Setting Up the HPD Service Monitor for Testing the
Base Radio
on page 199.
2 Using the soft keys on the right side of the screen, configure the service monitor GEN port to
generate inbound signaling to the base radio, as follows:
a Click the ON soft key under RF Gen.
b Click the GEN soft key under RF Out.
c Click the ENABLE soft key under Transmit.
3 Maximize the RF Control Settings window by clicking the upper left corner of the window.
All RF Control Settings
fields display.