Instruction Manual

Table Of Contents
Table 58: Minimum Software Download Version Requirements
ASTRO
®
25 Sys-
tem Release
HPD Site Repeater Multi-Site Conventional 3600
7.6 and earlier Not Supported N/A N/A
7.7 HPDBR_
R07.7X.023
SiteRptrBR_
R07.7X.031
MsBR_
R07.7X.033
N/A N/A
7.8 HPDBR_
R07.8X.033
SiteRptrBR_
R07.8X.038
MsBR_
R07.8X.038
N/A N/A
7.9 HPDBR_
R07.9X.049
SiteRptrBR_
R07.9X.050
MsBR_
R07.9X.051
ConvRptrBR_
R07.9X.051
Any Version
7.11 HPDBR_
R07.BX.098
SiteRptrBR_
R07.BX.102_P2
SiteRptrBR_
R07.BX.102_P2
MsBR_
R07.BX.102_X2
MsBR_
R07.BX.102_P2
ConvBR_
R07.BX.100
Any Version
7.12 HPDBR_
R07.CX.051
SiteRptrBR_
R07.CX.051_X2
SiteRptrBR_
R07.CX.051_P2
MsBR_
R07.CX.051_X2
MsBR_
R07.CX.051_P2
ConvBR_
R07.CX.057
Any Version
7.13 HPDBR_
R07.DX.073
SiteRptrBR_
R07.DX.079_X2
SiteRptrBR_
R07.DX.079_P2
MsBR_
R07.DX.079_X2
MsBR_
R07.DX.079_P2
ConvBR_
R07.DX.074
Any Version
7.14 and later Any Version
CAUTION: It is crucial that a site software download is performed at a trunked ASTRO
®
25 site
to ensure that all devices are on the same software version, VLAN, and active bank. Failure to
perform this step, results in the replacement transceiver or expansion channel to have a
mismatch in software versions. If a mismatch in software versions occurs, the transceiver may
go into a configuration mode of operation with a reason of ‘Invalid Software Version’.
A site software download is not available for conventional or trunked 3600 devices.
9.2.2
Identifying Transceiver Hardware Generation
Label
GEN 1 and GEN 2 transceiver modules can be identified by examining the physical hardware label.
GEN 2 modules have a light blue label with ‘GEN 2’ clearly noted on it, while GEN 1 modules have a
white label with no GEN identification.
MN003286A01-H
Chapter 9: GTR 8000 Base Radio FRU Procedures
228