Instruction Manual

Table Of Contents
3.3.13
Technical Support for Installation
Technical support is available from the site-specific documents the Field Engineer or Motorola
Solutions Field Representative provided for the system, one of the Motorola Solutions Support Centers
(SSC), or qualified subcontractors.
SSC can help technicians and engineers resolve system problems and ensure that warranty
requirements are met. Check your contract for specific warranty information. See Motorola
Solutions Support Center on page 220.
The Motorola Solutions System Service Subcontractor Assessment program ensures that service
people contracted by Motorola Solutions meet strict minimum requirements before they can work on
any system. For more information on this program, contact the Motorola Solutions representative.
3.3.13.1
Site-Specific Information
When the Motorola Solutions Center for Customer Solution Integration (CCSi) stages a system, the
Field Engineer assigned to the system creates all site-specific system documentation to document how
the system was staged. Site-specific information includes the following:
Site design drawings showing the location of racks, cabinets, cable trays, and other components
Rack drawings showing the location of the equipment in each rack
Cable matrix in a table format that shows each cable and its connections
Interconnect wiring diagrams to show the cable connections between devices
Pre-programmed parameters of each site component
Templates used to program each device
All firmware and software revisions of each site component
Test data from each device that requires operational verification
Optimization requirements and settings of each electrical path
Acceptance Test Plan for the site components
NOTICE: Maintain this site-specific information to reflect the current site configuration and
layout for the system.
3.4
GTR 8000 Base Radio Hardware Installation
The following is information specific to GTR 8000 Base Radios.
3.4.1
Placement and Spacing
Cabinets and racks allow equipment to be added to a site. Always consider room for expansion when
setting up a site. Cabinets or racks may be installed next to each other or to other equipment.
However, provide all cabinets and racks with sufficient floor space to permit access for installation and
service.
Clearance required for service and installation is at least 2 ft in the front and rear.
Front access:
At least 2 ft floor access in front of the cabinet or rack.