User's Manual

12 68P80801E35-A 9/1/2001
Parts and Suppliers EBTS System Manual - Vol 2
Anti-Oxidant Greases
Any one of the following anti-oxidant greases are recommended for connections
to the positive (+) and negative (-) terminals of the batteries:
No-Ox
OxGuard
Penetrox
Intercabinet Cabling
Ethernet and alarm cables connecting to the junction panels of each cabinet are
supplied with the system. These cables may not be suitable for every EBTS site. It
may be necessary to locally manufacture cables for a custom t. Information is
provided for both supplied cables and custom cables.
Supplied Cables
The cables listed in Table 6 are supplied with the system. The length of these
cables should be sufcient if the considerations outlined in the Pre-Installation
section are followed.
Making Custom Cables
If custom Ethernet or 5 MHz cables must be locally manufactured, use the part
numbers listed in Table 7 for ordering the required materials.
Table 6 Supplied Inter-Cabinet Cabling
Description Qty. P/N
120" long, N-type Male to N-type male cable 3 0112004B24
108" long, BNC Male-to-BNC Male, RG400
cable
2* 0112004Z29
210" long, 8-pin Modular plug cable 1* 3084225N42
186" long, PCCH redundancy control cable 1** 3082070X01
Phasing Harness 1 0182004W04
All part numbers are Motorola.
* Per RF rack.
** Per Control rack.
Table 7 Parts for Ethernet and 5 MHz Cables
Description Qty. P/N
Connector, BNC male As required 2884967D01
Cable, RG400 As required 3084173E01
All part numbers are Motorola.