Troubleshooting EBTS System Manual - Vol 2
Generation 2 Single Channel BR Station Verification Procedures
3. Enable Global Synchronization.
4. Disable System Gain.
NOTE
This step should only be performed if the Base Radio
is being connected directly to the Base Radio Antenna
ports. If verification is being performed at the top of
the rack (adding an RFDS), disregard the above
command.
5. Verify the R2660 signal level.
field> es -orx_all -tglobal
field> freq -orxch1 -f810
field> sge -orx_all -soff
field> enable -orxch1 -dbr1 -son
field> ppc -orych1 -mchn -s1
field> ppr -orxch1 -r1 -a100