User's Manual

68P80801E35-A 9/1/2001 29
EBTS System Manual - Vol 2 Troubleshooting
Generation 2 Single Channel BR Station Verification Procedures
12. Enter the command to return all active alarms of the Base Radio. At the
prompt, type:
NOTE
If the command displays alarms, refer to the System
Troubleshooting section for corrective actions.
13. As shown below respectively for 800 MHz Generation 2 Base Radios, the
following command returns the kit numbers of the receiver and all other
modules. At the prompt, type:
Equipment Disconnection
Disconnect equipment after verifying the receiver as follows:
1. Remove power from the Base Radio by setting the Power Supply rocker
switch (located behind the front panel of the Power Supply) to the OFF (0)
position.
2. Disconnect the RS-232 cable from the connector on the service computer.
3. Disconnect the other end of the RS-232 cable from the RS-232 connector on
the front panel of the BRC.
4. Disconnect the test cable from the RX 1 connector located on the backplane
of the Base Radio.
5. Connect the standard equipment cable to the RX 1 connector.
6. Disconnect the cable to the R2660 Communications Analyzer.
7. Restore power to the Base Radio by setting the Power Supply rocker switch
to the ON (1) position.
This completes the Receiver Verication Procedure for the receiver.
eld> alarms -ofault_hndlr
eld> fc oplatform