Pub. 43004-023D GAI-TRONICS® CORPORATION A HUBBELL COMPANY L3149B (C200) Advanced Tone Remote Desk Set GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA 610-777-1374 800-492-1212 Fax: 610-796-5954 VISIT WWW .GAI-TRONICS.
CONFIDENTIALITY NOTICE This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics. GAI-Tronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system.
Table of Contents FOREWORD ............................................................................................................................................................... 1 SCOPE OF MANUAL .................................................................................................................................................... 1 NOMENCLATURE ..............................................................................................................................................
Table of Contents L3149B (C200) Advanced Tone Remote Desk Set NUMERIC KEYPAD FREQUENCY SELECTION............................................................................................................. 14 FREQUENCY DISPLAY............................................................................................................................................... 14 PARALLEL STATUS OPERATION (TONE OPERATION ONLY) ......................................................................................
L3149B (C200) Advanced Tone Remote Desk Set Table of Contents MOUNTING ............................................................................................................................................................... 34 LEVEL ADJUSTMENTS AND DIAGNOSTICS................................................................................................................. 35 RELOADING FACTORY DEFAULTS....................................................................................................
Table of Contents L3149B (C200) Advanced Tone Remote Desk Set ALIAS TABLE............................................................................................................................................................ 66 TROUBLESHOOTING ............................................................................................................................................ 69 TROUBLESHOOTING THE L3149B (C200) ADVANCED DESK SET .................................................................
Foreword Scope of Manual This manual offers descriptive data and service information for the L3149B (C200) Advanced Tone Remote Desk Set. Service diagrams and printed circuit board details are a part of this service manual. Nomenclature The model number, located on the nameplate on the bottom of the unit, specifically identifies GAITronics equipment. If additional options are ordered, the option will be identified on the circuit board.
Foreword L3149B (C200) Advanced Tone Remote Desk Set Features and Benefits Feature Benefit Programmable 16-frequeny control with alias (Tone mode only) Any one of 16 EIA standard tones can be programmed for each frequency/function key along with an alias for each. LCD display User-friendly interface displays frequency alias, mode status and diagnostic information. Programmable buttons Four buttons provide up to eight user-defined actions, i.e., frequency selection, alert tones, and button mapping.
L3149B (C200) Advanced Tone Remote Desk Set Foreword FCC Interference Warning The FCC requires that manuals pertaining to Class A and Class B computing devices must contain warnings about possible interference with local residential radio and TV reception. This warning reads as follows: NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Foreword L3149B (C200) Advanced Tone Remote Desk Set 10. All low impedance test equipment (such as pulse generators, etc.) should be connected to CMOS device inputs after power is applied to the CMOS circuitry. Similarly, such low impedance equipment should be disconnected before power is turned off. 11. Replacement modules shipped separately from the factory will be packaged in a conductive material.
Description Physical Description The L3149B (C200) Advanced Tone Remote Desk Set provides a console-like alternative to conventional and CDM1550 LS Mobile Radio control. By adding the optional relay module to the L3149B Desk Set, the C200 can be configured for E&M and tone with E&M control allowing further possibilities for remote dispatch.
Description L3149B (C200) Advanced Tone Remote Desk Set Signaling Buttons Refer to the diagram above for the location of the front panel buttons. The following paging buttons are used for paging and initiating alert tones: MDC SELECT PAGE DOWN CLEAR UP The function and operation of each of the paging buttons is discussed in the Operations section of this manual.
L3149B (C200) Advanced Tone Remote Desk Set Description Monitor LED The MONITOR LED, located to the left of the button, illuminates when monitor is activated. Keypad Buttons The numeric keypad is used for the selection of a desired frequency, page capcode entry and MDC1200 ID entry. See the Operations section of this manual for further information. LCD Display Each of the desk sets includes a backlit 2 16 character LCD display for operator information.
Description L3149B (C200) Advanced Tone Remote Desk Set Accessories Description Part No. Desk Microphone XDM004A Desktop Gooseneck Microphone (requires XAAB002A) XDM005A Footswitch (requires XAAB002A) XFS002A Tone Remote Adapter ITA2000A Audio Accessory Box XAAB002A Amplified Headset, Single Earpiece (requires coiled cord) XHS003C Coiled Cord for XHS003C (requires XAAB002A) XCC004B Coiled Cord with PTT for XHS003C (requires XAAB002A) XCC003C Field Replacement Items Description Part No.
Operation Operational Description The L3149B (C200) Desk Set provides radio system control from a remote location. The desk set sends control to the remote adapter through a telephone line to control radio functions such as transmit, channel changes, and monitor. When programmed for local (L3147A) operation, the desk set can be used for extended local control of the radio system.
Operation L3149B (C200) Advanced Tone Remote Desk Set Setting the Clock 1. Power up the C200 Advanced Desk Set. 2. Wait for the message CHECKING PARAMETERS PLEASE WAIT to clear. 3. When the message L314XA VER. C2HXX C2DXX appears, immediately press the MDC button in the upper left hand corner of the key panel. 4. The message on the display will read ENTER HH:MM:SS. 5. Use the numeric keys to enter the hour, the minutes, and the seconds. 6. When complete, press the TRANSMIT button. 7.
L3149B (C200) Advanced Tone Remote Desk Set Operation Initiating Calls Before initiating a call in a conventional system, press the MONITOR button to verify that the radio channel is clear. Always allow time for the radio channel to be established. In addition, if the unit is configured to generate PTT IDs and to generate side tone, a tone will be heard during the PTT pretime and PTT generation.
Operation L3149B (C200) Advanced Tone Remote Desk Set Front Panel Buttons Signaling Buttons The signaling buttons operate as follows: MDC The MDC button is used to enter MDC mode. While in MDC mode, the operator may select from among various MDC1200 messages to be transmitted. These include Call Alert, Radio Check, Select Call, and Radio Enable/Disable. PAGE The PAGE button is used to enter page mode. While in page mode, the operator may select from among various types of pages to be transmitted.
L3149B (C200) Advanced Tone Remote Desk Set Operation VOLUME Up and VOLUME Down Buttons Press the VOLUME Up or Down buttons to adjust the local speaker volume if the handset is on-hook. The handset speaker volume is adjusted if the handset is off-hook. The display shows the new setting for 2 seconds after a volume change. The internal, handset, and accessory each have individual settings.
Operation L3149B (C200) Advanced Tone Remote Desk Set Numeric Keypad Frequency Selection The L3149B can be configured for controlling up to 16-frequency control with the XAC0008A C200 Programming Software. When the desired frequency is selected using the numeric keypad, that frequency change command is sent to the base. NOTE: Tone operation only: Other parallel units will reflect the newly selected frequency (Parallel Status Update).
L3149B (C200) Advanced Tone Remote Desk Set Operation Parallel Status Operation (Tone Operation Only) The L3149B Desk Set supports parallel status updating. This feature allows all dispatch positions to know the status of the base station. To decode this information, the unit actually senses high level guard tone (HLGT), then decodes the function tone that follows. Due to various tone control schemes supported by the unit, it is important to understand the rules of decoding the function tones. 1.
Operation L3149B (C200) Advanced Tone Remote Desk Set PTT Frequency This feature, compatible with tone and optional E&M with tone control, allows the desk sets to use only a single function tone burst generation when a voice transmission is required. The parallel status updating function is also modified. This is useful when the base station is only capable of one frequency control or when wildcard frequency keying is required.
L3149B (C200) Advanced Tone Remote Desk Set Operation Paging These desk sets support the following formats: DTMF 1500 Immediate DTMF 2805 2-Tone Custom 2-Tone 5-Tone Paging may be initiated by entering digits on the numeric keypad, by programming an alias using the XAC0008A C200 Programming Software, by configuring any of the programmable buttons, or by PC control. The alias feature allows user-determined names to be assigned to specific paging capcodes.
Operation L3149B (C200) Advanced Tone Remote Desk Set Entering a Programmed Alias If paging aliases have been programmed into the desk set, press either the UP or the DOWN button after entering the paging menu. To scroll alphabetically, press the combination of either LOCK + UP or LOCK + DOWN buttons. The alias that begins with the next (or the previous) letter of the alphabet is displayed.
L3149B (C200) Advanced Tone Remote Desk Set Operation MDC1200 Applicability These desk sets support the following MDC1200 encode features: PTT-ID used at the beginning of voice transmission to indicate to the receiving unit(s) who is transmitting Post PTT-ID used at the end of voice transmission to indicate to the receiving unit(s) who was transmitting. Call Alert used to alert mobile operators away from their radio to call the dispatch operator.
Operation L3149B (C200) Advanced Tone Remote Desk Set Sending the MDC1200 Message When the desired unit ID or alias appears on the display, press MONITOR to ensure that the radio channel is not in use. When the channel is free, press the TRANSMIT button or handset PTT bar. The MDC1200 message is sent according to the table below once a channel is established. If a channel cannot be established when using a CDM1550 LS Mobile Radio, “SYS NOT AVAIL” is displayed and the MDC message is not sent.
L3149B (C200) Advanced Tone Remote Desk Set Operation Select Call Select Call is a special MDC1200 type that is used to selectively signal an individual unit or a group of units. To initiate a Select Call, the operator must press and hold the TRANSMIT button or handset PTT bar. After the unit has transmitted the Select Call, the display shows “***TALK NOW***” on the second line of the display. The operator may then speak to the target unit.
Operation L3149B (C200) Advanced Tone Remote Desk Set A typical printout supported by the C200 is shown below. For these examples, the desk set’s unit ID is assumed to be 5678; the target unit’s ID is assumed to be 1234. The Line column and line numbers are added for discussion below.
L3149B (C200) Advanced Tone Remote Desk Set Operation MDC1200 MDC1200 allows the PC to direct the C200 to transmit a MDC1200 message using a preprogrammed alias or a specified unit ID. The behavior of the actual transmission is controlled by software programmed parameters.
Operation L3149B (C200) Advanced Tone Remote Desk Set Example 2: To send a call alert to MDC1200 alias 1 (i.e. FIRE 100) do the following. Note that the alias number is as listed in the software under MDC1200 aliases.
L3149B (C200) Advanced Tone Remote Desk Set Operation Alias paging works similarly to MDC1200 signaling with the alias number being as listed in the programming software for page aliases. Frequency Changing Frequency changing allows the PC to direct the C200 to change the current transmit frequency to a newly specified transmit frequency such as F12.
Operation L3149B (C200) Advanced Tone Remote Desk Set The frequency constant is calculated as (using C syntax): MSW = 0x00ff & round (frequency * 8.192) >> 1 LSW = 0xFF00 & round (frequency * 8.192) >> 8 Therefore, to generate 1234 Hz followed by 567 Hz the frequency constants must first be calculated. For 1234 Hz: MSW = (0x00ff & round (1234 * 8.192) ) >> 1 = (0x00ff & round (10108.
Installation Planning the Installation The following diagrams show examples of installations for the L3149B programmed for both tone (standard) or local control (L3147A) operation. Local Control (L3147A) Example Installation Diagram Shown connected in parallel within one building. NOTE: The distance between the desk set and the radio must not exceed 1000 feet when programmed for local control.
Installation L3149B (C200) Advanced Tone Remote Desk Set Tone Control (L3149B) Example Installation Diagram – Shown connected in parallel within one building Mechanical Receipt Inspection The desk sets are shipped in a cardboard container with inserts. Thoroughly inspect it as soon as possible after delivery. In-transit damage should be immediately reported to the transportation company. GAITronics is not responsible for damage incurred during transit.
L3149B (C200) Advanced Tone Remote Desk Set Installation The ground terminal must be connected to a high quality earth ground point to obtain maximum protection. Ideally, the ground point should originate at a 1/2-inch copper rod driven at least six feet into the soil with a No. 16 AWG (or larger) copper wire run to the ground terminal taking the shortest path possible. Where this is not possible, ground to a nearby water pipe or best available ground.
Installation L3149B (C200) Advanced Tone Remote Desk Set Line Connections for the L3149B Desk Set Connect the telephone line to the modular connector located on the back of the desk set. Telephone Line Pinout Pins Function Pin 1 N/C Pin 2 4-wire TX +IN Pin 3 2-wire RX +OUT/TX IN Pin 4 2-wire RX –OUT/TX IN Pin 5 4-wire TX –IN Pin 6 N/C Telephone Line Connector The six-pin modular jack is a full/half duplex connection to the line.
L3149B (C200) Advanced Tone Remote Desk Set Installation Line Connections for Local Control (L3147A) Operation When programmed for local operation (L3147A) the desk set provides extended local control of the radio. This operation requires PTT and monitor to be connected to J701 of the relay module in the base of the desk set as noted in the chart below.
Installation L3149B (C200) Advanced Tone Remote Desk Set Microphone Sensitivity Adjustments After connections have been made, the desk set must be configured for transmit and receive audio levels. These adjustments are made using the front panel buttons. The microphone sensitivity adjustment is used to compensate for different user voice levels and varied acoustical conditions. Refer to the following instructions to adjust the different microphones. Internal Microphone Place the handset in the cradle.
L3149B (C200) Advanced Tone Remote Desk Set Installation Relay Control NOTE: The following optional features require relay control option equipment (Kit No. XRC0001A) on the L3149B. Maximum load ratings for each relay output are 1 A @ 125 V ac and 2 A @ 30 V dc. E&M The XAC0008A Programming Software can be used to configure the L3149B for Local and E&M control. The unit can be configured for either E&M control or E&M with tone control.
Installation L3149B (C200) Advanced Tone Remote Desk Set Audio Accessory/RS-232 Port The desk sets contains an 8-pin modular audio accessory port to provide audio accessory options. Possible accessories include desk microphone, gooseneck microphone, boom microphone, headset, or footswitch. The microphone input type is passive, with an input impedance of greater than 2k ohms and a nominal input level of −20 dBm. Audio Accessory/RS-232 Port Pinout Pin No.
L3149B (C200) Advanced Tone Remote Desk Set Installation Level Adjustments and Diagnostics The programming buttons, PROG 1/5 through PROG 4/8, are used to navigate the menu for specific installations and to perform diagnostics. They are: Line Output Level Line In Sensitivity Diagnostics Tone Level Adjustments The diagram below illustrates which buttons to press to access the programming features.
Installation L3149B (C200) Advanced Tone Remote Desk Set Reloading Factory Defaults Desk sets are shipped from the factory with default settings that meet most installation requirements. However, it is important to verify that these parameters are adjusted to meet your specific installation needs. To reload factory defaults, enter the Main Diagnostic Selection as described below. After entering this mode, press LOCK + VOLUME Up. The unit will automatically reset and show that the parameters are corrupt.
L3149B (C200) Advanced Tone Remote Desk Set Installation Using a Communications Service Analyzer, or other RF generator, inject a fully-quieted (e.g.1000 microvolt) signal into the antenna port of the base station. Enable the RF generator’s 1 kHz tone, modulated at rated system deviation. Note the level of the 1 kHz tone imposed on the line at the remote line terminals. Program the desk set’s line level to the setting that approximates the audio level previously measured.
Installation L3149B (C200) Advanced Tone Remote Desk Set PROG 2/6 - DC Module Diagnostics This mode allows the dc board to be exercised with both positive and negative currents and sets the DCLOTL. The threshold for DCLOTL is adjustable, but is factory preset for most installations. The asterisk (*) is present in the lower right corner if the line voltage is above the preset DCLOTL threshold.
L3149B (C200) Advanced Tone Remote Desk Set Installation PROG 3/7 – RS-232 Diagnostic This diagnostic exercises the RS-232 port TX and RX data. To run this test, disconnect anything connected to the programming connector on the back of the unit, and short pins 2 and 7 of the connector. Once the short is completed, this unit sends data on the TX wire for receipt on the RX wire. If the same data is received on the RX wire, the unit continues to send data.
Installation L3149B (C200) Advanced Tone Remote Desk Set PROG 4/8 - Tone Level Adjust This mode allows adjustment of the levels of sidetone, the alert, and the page tones: The sidetone level used for speaker tones can be adjusted to suit the user. The alert and page tone line levels can be adjusted relative to HLGT.
Theory of Operation General Desk Set Overview The L3149B (C200) Advanced Desk Set is a multi-processor design employing state-of-the-art DSP technology to achieve superior performance over typical analog and single-processor designs. This allows for ultimate flexibility in audio processing. The heart of the design consists of U1, the DSP; and U3, the microcontroller. The DSP is responsible for audio processing of receive and transmit audio.
Theory of Operation L3149B (C200) Advanced Tone Remote Desk Set In addition to the transmit audio, data is combined with the transmit audio prior to line-out compensation at U11-3. U10-1 is the line-driver enable for the transmit audio. This provides for a 560-ohm transmit output impedance. Microphone Audio There are three sources for mic audio. These are the internal, handset and audio accessory mic. The microcontroller controls which mic is used based on the source of the PTT.
Programming PC Programming General Description C200 Programming Software (included on No. XAC4000A Programming Bundle CD) is needed to program the features of your equipment. It allows entry of programming data into your PC for transfer to your equipment. The programmed data can be retrieved and edited, and printed in hard copy form for recordkeeping. Hardware/Software Requirements This software is for use on PCs with Windows 95 or higher operating system (not compatible with Vista).
Programming L3149B (C200) Advanced Tone Remote Desk Set Desk Set Parameters Date Format The date may be displayed in one of the following four ways on the desk set: USA: month in numeral format; MM-DD (11-20) European: month in text format; DD Month (20 Nov) USA: month in text format; Month DD (Nov 20) European: month in numeral format; DD-MM (20-11) Clock Format Time may be displayed in either 12-hour or 24-hour mode. If the 12-hour mode is selected, the desk set displays A for a.m.
L3149B (C200) Advanced Tone Remote Desk Set Programming Accessory Mic Bias The mic bias for the accessory connector should be enabled if an electric condenser mic is used for transmit audio. Enabling this parameter allows approximately 4 volts of mic bias to be applied to the accessory mic high input. Accessory PTT Polarity If attached accessory uses a normally open switch for PTT with a closure to ground, this should be set for low active.
Programming L3149B (C200) Advanced Tone Remote Desk Set Type of Interface Select the type of interface depending upon the modules installed in the desk set: Tone Control is available regardless of what hardware is installed. If the relay I/O control module is installed, select E&M with Tone, E&M without Tone, or Local Control. Type of Wire Select between 2-wire and 4-wire interface. Select 2-wire if receive and transmit audio will be available on the same pair of wires.
L3149B (C200) Advanced Tone Remote Desk Set Programming Control Parameters Guard Tone Frequency The guard tone frequency is available when the type of interface is Tone or Tone with E&M control. This parameter allows the selection of the guard tone frequency for transmit and receive. Different guard tone frequencies are available for installations requiring them or where paging tones within the guard tone notch are needed. The tone adapter must be configured for the same guard tone frequency.
Programming L3149B (C200) Advanced Tone Remote Desk Set Monitor Frequency/Current When the type of interface is Tone, Tone with E&M, or DC control, this parameter selects the monitor frequency/current used when the monitor button is pressed. Parallel Mute Enabling this feature causes the unit to mute the speaker, not the handset, when a parallel unit is transmitting. This is useful when two or more parallel units are co-located and feedback from one unit to the other is possible.
L3149B (C200) Advanced Tone Remote Desk Set Programming Programmable Buttons The L3149B Desk Set has four programmable buttons. Each may be assigned up to two functions - one with the button alone and one when pressed with the LOCK button. Since there is only one LED per button, the LED only reflects the status of the normal function (programmable button pressed without LOCK). Therefore, certain functions that require the LED cannot be selected under the Programmable Button with LOCK fields.
Programming L3149B (C200) Advanced Tone Remote Desk Set Quick MDC Programming a button for Quick MDC allows two possible uses of the button. The first possible configuration is the selection of manual MDC in the next field. This allows a single button to enter the MDC menu using the programmed call type and allow the operator to select the target ID or alias. The operator may not select another call type. The second possible configuration is the selection of a programmed alias in the next field.
L3149B (C200) Advanced Tone Remote Desk Set Programming Input/Output Relay Table NOTE: This screen only appears if a relay board is present. The relay module consists of four physical relays and four inputs. Relays 1 and 4 are DPDT relays. Relays 2 and 3 are DPST relays. The relays are physically the same part, but I/O limitations of the module limit the number of connections to each relay. The inputs to the module are internally pulled-up and sense closure to ground only.
Programming L3149B (C200) Advanced Tone Remote Desk Set PTT Sense When configured for local control and with parallel units, the operator is not allowed to transmit during the transmission of a parallel unit. This input allows the desk set to sense parallel transmissions and lock-out transmissions until the parallel transmission is over. When this input is asserted, pulled to ground, the TRANSMIT LED flashes. When the input is disasserted, the TRANSMIT LED extinguishes.
L3149B (C200) Advanced Tone Remote Desk Set Programming Monitor When the Type of Interface is Local control, a monitor closure is necessary to place the radio in to monitor mode. This monitor relay is configured as a normally open momentary relay and is asserted when the MONITOR button is pressed and disasserted when the MONITOR button is not pressed. Note that the relay also contains a normally closed contact.
Programming L3149B (C200) Advanced Tone Remote Desk Set Manual Paging Page PTT Frequency If the system is configured such that pages should be transmitted on a particular channel, the page PTT frequency may be used. This parameter allows the selection of the page PTT frequency for all manual pages. In addition the desk set can be configured to remain on the page PTT frequency until manually changed by the operator.
L3149B (C200) Advanced Tone Remote Desk Set Programming Two-Tone Paging Two-Tone Codeplan Allows the selection of the Two-Tone Codeplan from the following list. Please refer to the Tone Group Frequency Chart and the Code Plan Chart below for the specifics for each codeplan. NOTE: This parameter affects alias paging as well. Tone Group Frequency Chart Tone Group # 0 1 2 3 4 5 6 7 8 9 Group No. 1 330.5 349.0 368.5 389.0 410.8 433.7 457.9 483.5 510.5 539.0 1 2 569.1 600.9 634.
Programming L3149B (C200) Advanced Tone Remote Desk Set Code MSD Digit of 3 Digit Capcode Plan 0 1 2 3 4 5 6 7 8 9 F N/A 11 13 33 44 31 14 41 34 43 G N/A 11 13 33 31 55 15 51 35 52 H N/A 11 13 33 31 16 66 61 36 63 J N/A 11 14 41 44 55 15 45 54 51 K N/A 11 14 41 44 16 66 61 46 64 L N/A 11 15 51 16 55 66 61 56 65 M N/A 23 22 33 44 32 24 42 34 43 N N/A 23 22 33 32 55 25 52 35 53 P N/A 23 22 33 32 26 66
L3149B (C200) Advanced Tone Remote Desk Set Programming Preset Two-Tone Digits This allows up to three 2-tone paging digits to be preset and controls the number of digits the operator must enter. If two preset digits are entered, the operator is only allowed to enter the third digit. The valid range for each digit is 0-9. A Tone Duration This parameter allows the duration of the first tone of the two-tone sequence to be set. The valid range is 0.5 sec to 4.5 sec in 0.5 sec increments.
Programming L3149B (C200) Advanced Tone Remote Desk Set Tone Group P1 643 672 701 732 765 799 834 871 910 950 Tone Group P2 992 1036 1082 1130 1180 1232 1287 1344 1403 1465 Tone Group P3 1530 1598 1669 1743 1820 1901 1985 2073 2164 2260 Tone Group P4 2361 2465 2575 2688 2807 2932 3062 3197 3339 3487 Tone Group P5 282.2 294.7 307.8 321.4 335.6 330.5 366.0 382.3 399.2 416.9 Tone Group P6 435.3 454.6 474.8 495.8 517.8 540.7 564.7 589.7 615.
L3149B (C200) Advanced Tone Remote Desk Set Programming 5-Tone Paging 5-Tone Paging Preamble Allows the selection of a 5-tone preamble number from the following list: NOTE: This parameter affects alias paging as well.
Programming L3149B (C200) Advanced Tone Remote Desk Set 1500 Paging 1500 Paging Tone Off Time Allows the selection of the length of the Tone Off Time for 1500 paging. The Tone On Time is as follows: Tone On Time = 100 ms – Tone Off Time. NOTE: This parameter affects alias paging as well. Maximum Digits Allowed From Keypad This parameter controls the selection of the maximum number of digits that may be entered from the keypad by the operator. The valid range is 0 to 6.
L3149B (C200) Advanced Tone Remote Desk Set Programming Configure MDC1200 MDC Feature Order This feature allows you to select which manual paging types or MDC types will be available on the C200. You may also determine the order in which the selected paging types appear. NOTE: Paging types enabled have no effect on which MDC types are available in any part of the programming software. All paging and MDC types will be available.
Programming L3149B (C200) Advanced Tone Remote Desk Set MDC Group ID The MDC Group ID is the RapidCall group ID of the unit. This ID is not unique to a particular unit, but to a group of units. It is used only when determining whether a specific RapidCall message is intended for itself. The valid range is from E001 to EEEE. The ID cannot be E000 or contain a wildcard or F.
L3149B (C200) Advanced Tone Remote Desk Set Programming Emergency Ack Enable This parameter enables/disables the generation of MDC1200 emergency, status and message acknowledgments. If enabled, the desk set acknowledges MDC1200 emergency, status and message messages. Only one desk set per system should be enabled to acknowledge emergencies, statuses and messages. If disabled, no acknowledgment is generated for MDC1200 emergency, status and message messages. See also Emergency Enable.
Programming L3149B (C200) Advanced Tone Remote Desk Set MDC Timers DOS Coast Timer The data-operated squelch is used to mute receive audio after the receipt of MDC data. This parameter controls the length of time the speaker remains muted after a MDC1200 receive. The valid range for this parameter is 0–2000 ms in 10 ms increments. Emergency Ignore Time This is the time that the unit will ignore subsequent emergency decodes from the same unit.
L3149B (C200) Advanced Tone Remote Desk Set Programming MDC Printer Message Settings Allows the user to specify which incoming and outgoing MDC messages are logged to the printer. These settings can only be edited if the printer is enabled.
Programming L3149B (C200) Advanced Tone Remote Desk Set Alias Table The Alias Table allows storage of up to 250 distinct Paging or MDC profiles in the C200. This screen allows you to Add, Delete and Change entries. All aliases currently entered in the table can be seen in the Table Entries field. The alias order in the table, alias type, paging type (if applicable), name, capcode (if applicable) and the programmable button it is linked to (if applicable) are displayed.
L3149B (C200) Advanced Tone Remote Desk Set Programming Auto PTT Frequency This parameter selects the page PTT frequency for each paging alias. This allows the page to be sent on the same channel each time the page is sent. Keep Page PTT Freq after Page Normally, the unit reverts to the set function tone after a page is complete and talk time expires. Setting this parameter causes the unit to stay on the page channel until the user manually changes back.
Programming L3149B (C200) Advanced Tone Remote Desk Set Group Paging Allows sequential execution of up to six of the paging entries in the alias table. Only one group can be allowed to be a member of another group. The group entry will always be the last entry in a group. Restrictions can be added to a group: There must be no more that six group members, including no more than one group. Only groups that do not contain other groups may be added.
Troubleshooting Troubleshooting the L3149B (C200) Advanced Desk Set The following is a list of potential problems you may encounter and possible solutions. Problem Possible Solution General Problems The unit has no LED or LCD display Ensure that the unit is receiving dc power. Check for a blown fuse. The keyboard does not respond. Ensure that the PTT or monitor input on the audio accessory port is not activated.
Troubleshooting Problem L3149B (C200) Advanced Tone Remote Desk Set Possible Solution Local Control (L3147A Mode) Problems The desk set will not cause the transmitter to key. Ensure that the PTT relay is properly programmed with the XAC0008A Programming Software. Ensure that the PTT relay has a ground connection. Ensure that the PTT relay is activated when TRANSMIT is pressed. Ensure that the PTT relay is properly connected to the radio The desk set will not place the radio in monitor mode.
Schematics 71
Schematics L3149B (C200) Advanced Tone Remote Desk Set Desk Set Line Interface Schematic Diagram - Sheet 1 72
L3149B (C200) Advanced Tone Remote Desk Set Schematics Desk Set User Audio I/O Schematic Diagram - Sheet 2 73
Schematics L3149B (C200) Advanced Tone Remote Desk Set Desk Set Control Microprocessor I/O Schematic Diagram - Sheet 3 74
L3149B (C200) Advanced Tone Remote Desk Set Schematics Desk Set DSP Block Schematic Diagram - Sheet 4 75
Schematics L3149B (C200) Advanced Tone Remote Desk Set Desk Set Tone Keypanel Schematic Diagram - Sheet 5 76
L3149B (C200) Advanced Tone Remote Desk Set Schematics Desk Set Power Supply Schematic Diagram - Sheet 6 77
Schematics L3149B (C200) Advanced Tone Remote Desk Set Desk Set Signaling Section Schematic Diagram - Sheet 7 78
L3149B (C200) Advanced Tone Remote Desk Set Schematics Relay I/O Option Schematic Diagram (XRC0001A) 79
Schematics L3149B (C200) Advanced Tone Remote Desk Set NOTES: 80
Circuit Boards 81
Circuit Boards L3149B (C200) Advanced Tone Remote Desk Set Main Unit DTD Circuit Board 82
L3149B (C200) Advanced Tone Remote Desk Set Circuit Boards Main Unit Power and Line Circuit Board 83
Circuit Boards L3149B (C200) Advanced Tone Remote Desk Set Relay I/O Option Circuit Board 84
Definitions and Acronyms Term Definition CSQ Carrier squelch CTS Clear-to-send DPDT Dual-Pole Double Throw DPST Dual-Pole Single Throw DPL Digital Private Line - a system analogous to Private Line but using low speed digital signaling instead of subaudible tones. HLGT High level guard tone LLGT Low level guard tone LOTL Line Operated Transmit Light LTR Logic Trunked Radio MDC Motorola Digital Communication PL Private Line - is a means of grouping users of a common radio channel.
Notes L3149B (C200) Advanced Tone Remote Desk Set 86