Specification Sheet

PRODUCT DATA SHEET
CLS SERIES
¹ Available in Canada Only
² Range will vary based on terrain and conditions.
³ National Electrical Manufacturers Association
CLS radios’ tough polycarbonate housings contain built-in anti-microbial properties that inhibit the growth of bacteria and mold on the radio surfaces (does not include accessories).
CLS chargers and power supplies are ROHS and CEC (California Energy Comission) Power Level V energy efficient compliant.
Specifications subject to change without notice. All specifications shown are typical.
MILITARY STANDARDS
810-C 810-D 810-E 810-F 810-G
METHOD PROCEDURES METHOD PROCEDURES METHOD PROCEDURES METHOD PROCEDURES METHOD PROCEDURES
Low Pressure 500.1 I 500.2 I, II 500.3 I, II 500.4 I, II 500.5 I, II
High Temperature 501.1 I, II 501.2 I, II 501.3 I, II 501.4 I, II 501.5 I, II
Low Temperature 502.1 I 502.2 I, II 502.3 I, II 502.4 I, II 502.5 I, II
Temperature Shock 503.1 I 503.2 I 503.3 I 503.4 I, II 503.5 I
Contamination by Fluids 504.1 II
Solar Radiation 505.1 I 505.2 I 505.3 I 505.4 I 505.5 I
Rain 506.1 I, II 506.2 I, II 506.3 I, II 506.4 III 506.5 III
Humidity 507.1 I, II 50 7.2 II, III 50 7.3 II, III 5 07.4 5 07.5 II
Dust 510.1 I 510.2 I 510.3 I 510.4 I, III 510.5 I
Vibration 514.2 VIII, X 514.3 I 514.4 I 514.5 I 514.6 I
Shock 516.2 I, II, V 516.3 I, IV 516.4 I, IV 516.5 I, IV 516.6 I, IV
CLS radios meet test methods from Military Standards 810 C, D, E, F, and G for 11 items including shock, vibration, extreme temperatures and dust. CLS radios also satisfy environmental and energy
efficiency certifications (CE/CEC, ROHs and WEEE).
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature -30ºC to +60ºC (Radio)
Storage Temperature -40ºC to +85ºC (Radio)
Shock & Vibration Per MIL STDs 5 foot drop to concrete
Dust & Humidity Per MIL STDs IP5X IPX2
Enclosure Rating Designed to meet NEMA3 types 1, 2, 5
FCC (Federal Communications Committee) Designation: AZ489FT4926. IC (Industry Canada) Designation: 109U-89FT4926