Master Enable #4 [Y/N] N Do not set up and enable the Master
Address Decoder #4.
Master Starting Address #4 00000000 Base address of the VMEbus resource
that is accessible from the local bus.
This will be the local bus address.
Default is $0.
Master Ending Address #4 00000000 Ending address of the VMEbus
resource that is accessible from the
local bus. This will be the local bus
address. Default is $0.
Master Address Translation
Address #4
00000000 This register will allow the VMEbus
address and the local address to be
different. The value in this register is
the base address of the VMEbus
resource that is associated with the
starting and ending address selection
from the previous questions. Default
is $0.
Master Address Translation Select
#4
00000000 This register deÞnes which bits of the
Translation Address are signiÞcant. A
logical one "1" indicates signiÞcant
address bits, logical zero "0" is non-
signiÞcant. The non-signiÞcant bits
will come from the local bus address
that accesses the VMEbus. Normally
MS bits will be set, down to the size of
memory to be accessed.Default is $0.
Master Control #4 00 Works the same as Slave Control #1.
Default is $00.
Short I/O (VMEbus A16) Enable
[Y/N]
Y Yes, Enable the Short I/O Address
Decoder.
Short I/O (VMEbus A16) Control 01 Works the same as Slave Control #1.
Default is $01.
Table A-1. ENV Command Parameters (Continued)
ENV Parameter and Options Default Meaning of Default