Release Notes Version 4.
1 Copyright and Trademark Notice Copyright © 2001-2014, Miranda Technologies Partnership. Belden, Belden Sending All The Right Signals, and the Belden logo are trademarks or registered trademarks of Belden Inc. or its affiliated companies in the United States and other jurisdictions. Miranda, iControl, Kaleido-X, Kaleido-K2, Kaleido-Alto, NVision, and Densité are trademarks or registered trademarks of Miranda Technologies Partnership. All rights reserved. Belden Inc.
Table of Contents 1 Installation and Network Requirements . . . . . . . . . . . . . . . . . . 1 Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Software Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Installation and Network Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
toc iv
Installation and Network Requirements This section details the requirements that must be met prior to installing or upgrading a system with the current version of iControl. It also provides upgrading and configuration guidelines, as well as tips to improve performance. Summary Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Software Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation and Network Requirements Supported Servers Graphics Card Optimized for nVidia or ATI GeForce or Radeon family with 1 GHz clock speed or faster, and minimum 128 MB memory. Supported Servers iControl version 4.40 is supported on the following Application Servers: Dell PowerEdge 850/860/R200/R210/R310.
iControl Release Notes In order to be able to modify the Configuration Spreadsheet used to define the iControl monitoring layout, you will need a PC with Microsoft® Excel®. Installation and Network Requirements Users can access the iControl Application Server from a client PC using a standard Web browser (Microsoft Internet Explorer or Mozilla Firefox). When a client logs in and launches an iControl module, the software is automatically downloaded from the Application Server.
Installation and Network Requirements Upgrading Upgrading iControl version 4.40 is shipped with all new systems. If you are planning to upgrade an existing iControl system to version 4.
iControl Release Notes request an upgrade package (see "Contact Us", on page 69). Upgrading from iControl 1.xx Previous versions (1.xx) of iControl are not compatible with release version 2.00 (and later). Configuration files cannot be reused. User-configured items such as iC Navigator aliases, error log settings and proc amps must be regenerated (we recommend you record all values before proceeding with an upgrade). Old iControl Web sites will be converted, but the links will need to be reassigned.
Installation and Network Requirements Upgrade Compatibility Issues Upgrade Compatibility Issues IMPORTANT: Previous replication configuration data does not survive upgrade For upgrades from an iControl version prior to 3.41 to version 4.40, you will need to reconfigure and enable replication after performing the upgrade. Do this on the Redundancy Configuration Form using the Manual Takeover mode. This applies to any upgrade from a version prior to iControl version 3.41 to either version 3.41 or later.
iControl Release Notes • The RMON driver is not backward compatible between versions 3.00 (and later) and 2.7: • Typical alarm URI in iControl 2.7 = //snmp:RMON/10.4.0.2/ifOperStatus101 • Equivalent alarm URI in iControl 3.X = snmp://RMON:10.4.0.2/ifOperStatus101 iC Web sites using these alarms may need to be updated accordingly. • iControl Rollback is supported between same major versions only (e.g. between 2.74 and 2.73). The Rollback feature will not work between 3.xx and 2.7x.
Installation and Network Requirements Configuration Guidelines Configuration Guidelines Large Kaleido-X System • When iControl is connected to a large Kaleido system, using the Kaleido-X SNMP plug-in to retrieve alarms may cause system performance issues as well as an Out of Memory error. Workaround: When attempting to retrieve multiviewer alarms, you should use the remote multiviewer GSM logging functionality on the Kaleido-X.
iControl Release Notes • Up to three Densité Managers per Application Server can be configured to support up to 150 streams each. One thumbnail, one ALM, one waveform/vector scope and the CC count as four separate streams. When using probes with streaming capabilities, no more than 150 cards should be allocated to one Application Server. • As of iControl version 3.30, overall and GSM contribution alarms are disabled by default for all Densité services.
Installation and Network Requirements Tips to Improve Performance Windows 2000 for the Java application when running Windows XP, or XP when running Windows 7 removed the problem (For more information about running Java in Windows2000 Compatibility mode, see the Quick Start Guide). • Do not start services on the iControl Application Server that are not required. By default, the Densité Manager, the RMI Daemon with lookup service and the GSM service are configured to start at boot time.
Release Notes iControl version 4.40 is a major release with several new features, enhancements, and bug fixes. The Release Notes document lists new features, bug fixes, known issues and limitations as well as peripheral cards and devices supported in the current release. Summary New Features and Enhancements in iControl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Bugs Fixed in iControl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Release Notes New Features and Enhancements in iControl New and changed in iControl version 4.40 (listed by reference #) (Continued) New and enhanced Fixed bugs Known issues Supported hardware ICONTROL-15903 , on page 14 ICONTROL-15904 , on page 14 ICONTROL-15905 , on page 14 ICONTROL-15846 , on page 14 New Features and Enhancements in iControl New and Enhanced in Version 4.40 Context-Sensitive Event Log Viewer of iC Web [Ref. #ICONTROL-15850] In version 4.
iControl Release Notes Figure 2-2 Using the Add to search criterion feature in the context-sensitive Log Viewer Note: If the context of a context-sensitive Event Log Viewer is a virtual alarm, the URI field — under Alarm properties in the Search filters area — is automatically populated with the URI of that virtual alarm. See also For more information, see the “Device-Specific Event Log Viewer” section in the “Logs” chapter of the iControl version 4.40 User Guide (M226-9900-279).
Release Notes New and Enhanced in Version 4.30 • [Ref. #ICONTROL-12821] Cisco D9036 Modular Encoding Platform device • [Ref. #ICONTROL-12844] Ross Video Production Technology OpenGear frame and • • • • • • • • • • • [Ref. #ICONTROL-12858] EVS XT/XS-series video production servers modules [Ref. #ICONTROL-12874] Rohde & Schwarz Exciter when operating in ATSC mode [Ref. #ICONTROL-12908] Rohde & Schwarz AEM100 emission multiplexer [Ref.
iControl Release Notes • [Ref. #23857] iC Router Control now supports importing NVISION configuration data into Router Manager Configurator. See also For more information, see the “Importing an NVISION Physical Router Configuration” section in the iControl Router Manager Quick Start Guide (M446-2800-100). iControl Integration with ScheduALL • iControl version 4.
Release Notes iControl Integration with ScheduALL Figure 2-4 Editing the ScheduALL connector plug-in (Main tab) Figure 2-5 Editing the ScheduALL connector plug-in from the Admin | Alarms tab 16
iControl Release Notes Figure 2-6 Main tab of ScheduALL Plug-in Configuration window Figure 2-7 Data tab of ScheduALL Plug-in Configuration window Figure 2-8 ScheduALL Circuit (Bookings) Data table 17
Release Notes Logging and Analyzing Loudness Data Figure 2-9 ScheduALL Device Data table Logging and Analyzing Loudness Data • Certain devices like the Kaleido-Solo are capable of monitoring the loudness of audio streams. The data generated from monitoring may be streamed to an Application Server whereiControl’s Loudness Logger can record and archive this stream of loudness data to a dedicated, external drive.
iControl Release Notes Support for SNMP version 3 • [Ref. #34226] iControl version 4.30 introduces support for SNMP version 3. SNMPv3 has as a primary purpose the task of providing a secure environment for managing devices, systems, and networks. Version 3 specifically protects against the following: • Modification of information: Countering the in-transit altering of SNMP messages by unauthorized SNMP entities.
Release Notes Re-designed Interface for Viewing and Editing Lookup Tables Re-designed Interface for Viewing and Editing Lookup Tables • [Ref. #31901] As in the past, iControl’s method of making network services and devices aware of one another’s presence is through the use of lookup tables. You can view and edit lookup tables directly in iControl’s Lookup locations page. In version 4.
iControl Release Notes • [Ref. #34315/34920] iControl supports the Axon frames RRS08 (version 34) and RRS18 (version 34) as well as the following Axon modular interfacing and conversion cards.
Release Notes Densité Services Densité Services REF-1801/SGP-1801 • [Ref. #34721] The REF-1801 and SGP-1801 Densité modules now report timecode data to iControl’s GSM. Support for Remote Desktop in iC Web • [Ref. #21515] iControl Web introduces support for a Remote Desktop session in a zone as an alternative to embedding a VNC client session in a zone.
iControl Release Notes • [Ref. #33936] iControl now supports the Evertz MSC5600 device. • [Ref. #33695] iControl now supports the Motorola CAP-1000 CherryPicker Application Platform. The CAP-1000 device is a multiplexer and encoder used to multiplex several SD/HD services encoded in MPEG-2 and MPEG-4 formats. See also For more information, see the “Motorola” section of the iControl Supported Devices Reference Guide. New in Version 4.12 SNMP Drivers • [Ref.
Release Notes Application Server Health Monitoring Application Server Health Monitoring • [Ref. #32469 / 31806] iControl version 4.11 improves upon the health monitoring capability of iControl with the addition of several Application Server, hardware-related alarms informed by hardware sensors. The alarms provide sensor information in the categories of temperature, current, voltage, fans, and chassis.
iControl Release Notes Sensor-derived Health Monitoring | Application Server alarms for an R310 (Continued) Alarm category Alarm Fan Fan 1A speed [RPM] Fan 1B speed Fan 2A speed Fan 2B speed Fan 3A speed Fan 3B speed Fan 4A speed Fan 4B speed Fan 5A speed Fan 5B speed Fan redundancy Temperature Ambient temperature [degrees Celsius] CPU temperature [degrees Celsius; actual, range to critical threshold] Memory module temperature [degrees Celsius; actual] Planar temperature Power supply 1 ambient tempera
Release Notes iC Router Control See also For more information about alarms for the health monitoring of Application Servers, see the “Alarms in iControl” chapter of the iControl Version 4.11 User Guide. iC Router Control • [Ref. #32092 / 28098] Evertz Quartz Type 1 ASCII Protocol: Support for viewing router error conditions on iC Web clients. iC Web • [Ref. #31998] iControl Web now allows you to specify the dimensions of your desired Total Fullscreen size (Ctrl + F11).
iControl Release Notes New in Version 4.10 Densité Services • [Ref. #31399] HDA-1851: Support for the new HDA-1851 Densité card. The HDA-1851 card is an HD/SD/ASI distribution amplifier with up to nine outputs and automatic equalization for up to 140 meters. It also offers signal presence detection and remote reporting. The card’s multiformat features make it ideal for applications where HD and SD signals may coexist. iControl version 4.10 introduces firmware version 1.0.0 of the HDA-1851 Densité card.
Release Notes New in Version 4.03 See also For more information, see the iControl Supported Device Reference Guide (M226-0900-102). New in Version 4.03 Densité Services • [Ref. #31025] SDA-1402: Support for the new SDA-1402 Densité card. The SDA-1402 card has the same functionality as the SDA-1401 card but adds compatibility with the rear connector panels of the HDA-18xx and HDA-19xx cards. iControl version 4.03 introduces firmware version 1.0.0 of the SDA-1402 card. • [Ref.
iControl Release Notes iC Creator • [Ref. #30007] You can now clear an iC Web zone by setting the view property in the Zone object to null or undefined. See also For more information, see iC Creator’s Script Help on the Help menu. SNMP MIB Files • [Ref. #30245] The list of Miranda MIB files accessible through the SNMP MIB Browser and SNMP Driver Creator has been updated to include MIB files for the following product categories: • Imagestore • • NVISION Omnibus New in Version 4.
Release Notes SNMP Driver Creator • ADX-3981 • • AMX-3981 EAP-3901 See also For more information, see: • the “Lip-Sync Detection and Monitoring” section in the “Working with iControl as an Operator” chapter of the iControl User’s Guide. • the “Configuring Lip-Sync Detection through iControl - Administrator Tasks” section in the “Working with iControl as an Operator” chapter of the iControl User’s Guide.
iControl Release Notes See also (Continued) For more information, see: • the “Filtering a Log Search Using Multiple Criteria” section in the “Event & Incident Log” chapter of the iControl User Guide. Event Log Viewer • When configuring search (filtering) parameters in iC Navigator’s or iC Web’s Event Log Viewer, you can now use the OR Boolean operator to include multiple criteria against the same field.
Release Notes iC Web, iC Navigator – New Statistics Panel in Miranda Media Player Right-click the ALM to view the shortcut menu. Figure 2-10 Audio stream shortcut menu to open the Statistics panel in iC Web Right-click the video thumbnail to view the shortcut menu.
iControl Release Notes Figure 2-12 Statistics panel opened in iC Navigator Element Unit Description RTP Source ASCII string Stream source Bit rate kbps An instant snapshot of the incoming bit rate in kilobits per second. Bit rate average kbps An average value of the current stream bit rate calculated over the last 10 seconds. Frame rate fps Frame rate of the current video stream (not applicable for audio).
Release Notes iC Creator, RCP-200 – New Kaleido-X Widget (Continued) Element Unit Description Lost number of packets The difference between the number of packets expected as determined by the RTP sequence number and the count of packets actually received and validated. Invalid # of packets The total number of RTP data packets that have failed to be within an acceptable sequence number range for an established connection.
iControl Release Notes • Scaled: The aspect ratio of the widget remains constant. • • Fixed width, variable height. Fixed height, variable width. After you allow a widget to be freely resizable by enabling the option in the widget page properties panel, you can provide a page resize event handler script that responds to the space allocated for this widget. Typically this might involve dynamically positioning and resizing its child components at runtime.
Release Notes iControl – New Look for iControl’s Web Interface Figure 2-14 iControl Miranda page Figure 2-15 iControl Miranda Setup page 36
iControl Release Notes Figure 2-16 iControl Redundancy Configuration Form Miranda Media Player • [Ref. #25258] IRD streams from Application Servers are now standard H.264. Support for Windows 7 • [Ref. #24866] iControl version 4.00 fully supports the Windows 7 platform. Bugs Fixed in iControl Fixed in Version 4.40 Fingerprint Analysis [Ref. #ICONTROL-12852] The formatting of fingerprint analysis alarm URIs is inconsistent across the different card types. iControl Creator [Ref.
Release Notes Fixed in Version 4.30 Fixed in Version 4.30 Incident Logs • [Ref. #20904] In iControl Navigator’s Incident Template window, when an alarm status changes, the selection data contained within the table may be lost. With the introduction of a new Show live statuses check box on the Incident Templates and the Incident Template Configuration windows, you can choose to disable live updating of sub-alarm statuses, thus allowing you to process the selections of the table at your leisure.
iControl Release Notes Fixed in Version 4.12 Densité Services • [Ref. #31082] 3DX-3901: In the 3DX-3901 Control Panel, the Critical Health Failure alarm is not visible in the Alarm Configuration panel. • [Ref. #33089] FIO-1901: In the FIO-1901 Control Panel, when attempting to copy a FIO-1901 card’s alarm profile to other cards, the other cards are not visible in the Copy to other cards menu. Fixed in Version 4.11 Densité Services • [Ref.
Release Notes Security Infrastructure Security Infrastructure • [Ref. #32065] The GSM service may fail to start after restoring iControl version 4.10 to an Application Server that has been recently ghosted. Fixed in Version 4.10 General Status Manager • [Ref. #15887/30843] On systems with multiple GSMs and deep hierarchies of virtual alarms, acknowledging virtual alarms may cause latency or unresponsiveness of one or more GSMs. Miranda Media Player • [Ref.
iControl Release Notes • [Ref. #28868] IRD-3811: When the IRD-3811 control panel is opened and closed frequently, the system CPU and memory usage may increase beyond expected levels. iC Router Control • [Ref. #27111] iControl does not support the NVISION Ethernet protocol – Enterprise router (Logical) router. Note: To benefit from this protocol’s full feature set in the context of iC Router Control, your NV9000 system controller must have version 6.0.0 or later. Miranda Media Player • [Ref.
Release Notes Densité Services Densité Services [Ref. #ICONTROL-12724] HCO-3901: When the refresh rate of an HCO-3901 card is set to 10 seconds, after you power up the card, thumbnails do not display on the thumbnail panel. Workaround: Toggle the refresh rate to FAST and then back to 10 seconds. [Ref. #ICONTROL-12901] Lumo Controller Service: When attempting to rename the Lumo controller service in iControl Navigator, the controller may disappear from iC Navigator’s view.
iControl Release Notes • [Ref. #17030] RALM (Remote Audio Level Meter) streams on Densité cards are sometimes lost if the Application Server’s host name is modified. • [Ref. #5327/5324] It could happen that a Densité frame assigned to m[ore than one Densité Manager remains assigned to both Densité Managers even after the Densité frame is removed from one of the Densité Managers. To correct this problem, from iControl Webmin, stop and then restart the Densité Manager service. Device Profile Manager • [Ref.
Release Notes Fingerprint Analysis • [Ref. #24578] When the GSM is restarted while the Event Log Viewer or Incident Log Viewer is open in Auto-Update mode, a stackOverFlowError message may appear in the Java Console window. Workaround: If using iControl Navigator, re-open the Event Log Viewer (or Incident Log Viewer). If using iControl Web, refresh the Web page. • [Ref.
iControl Release Notes • • • • If you have a Dell PowerEdge R310 Application Server, iControl supports a maximum of 120 audio fingerprint comparisons. A group is composed of a reference source and 1 or more probe sources. For the purposes of counting comparisons, the reference source is not counted. Application Servers used for comparison should be dedicated (i.e. they should not run other resource-intensive services). For older Application Server platforms (e.g.
Release Notes iC Core displayed as “20:35.9”. The problem is that Excel is attempting to guess the data type and fails. Workaround: Specify a format explicitly by selecting the column, then Format > Cells (or Ctrl+1), and specify a custom format like “yyyy-mm-dd hh:mm:ss.000” (to obtain the same result as described above). • [Ref. #2712] The GSM plug-ins for SNMP devices do not prevent duplicate instances for the same device.
iControl Release Notes iC Navigator • [Ref. # 22767] Intermittently, the overall status of one or more cards below a selected row in the list is not updated. Clicking on a card to select it updates its status. This behavior occurs in both Logical and Physical views and on all types of cards. Note: This behavior does not occur in the GSM Alarm Browser. • [Ref.
Release Notes iC Web iC Web [Ref. #ICONTROL-13742] On client systems running Microsoft Windows 7 or Windows Vista, you may not be able to load a Web browser in an iC Web zone. Workaround: Do one of the following two options: • Disable the User Access Control (UAC) in Windows. • OR, Enable the Windows2000 Compatibility mode on the Java executable file. • Some icons appearing in sites created by earlier versions of iC Creator will not be properly sized or scaled when used with iControl version 3.
iControl Release Notes Imagestore • [Ref. #35435] On the control panel for an ImageStore device, when you click one of the Video GPI or Audio GPI buttons on the Control tab, the system activates a different virtual GPI than was indicated.
Release Notes Loudness Logger/Analyzer iControl Services and Working with Imaging Communicators, in the iControl User’s Guide), or wait for the problem to correct itself (an auto-restart task ensures that any process that has failed is restarted; the auto-restart task runs every 60 seconds). Loudness Logger/Analyzer [Ref.
iControl Release Notes • [Ref. #37262] If the Loudness Logger is active while you switch inputs to the Kaleido-Solo (KS910), the Logger may not recover (restart logging) automatically. In such a case, on the Loudness Logger configuration page, the corresponding KS910 would display NO DATA. Workaround: To recover logging capability: 1. Open the Densité Manager. 2. Select the problematic Kaleido Solo. 3. Put the Kaleido Solo in Standby mode. 4. Put the Kaleido Solo in Online mode. • [Ref.
Release Notes Platform and Support Platform and Support [Ref. #ICONTROL-15831] Application Servers of the Dell R200 model use a Linux kernel that does not support 4GB of RAM. This decreases the amount of usable memory in such systems to 3.3GB. [Ref. #ICONTROL-12784] When upgrading iControl, the log window does not auto-scroll to the most recent logged upgrade event. Consequently, after an upgrade is complete, the instruction in the log window to reboot is not immediately visible. Workaround: complete.
iControl Release Notes • [Ref. #30978] iControl’s Edit Service Location Web page may not function properly when using Mozilla Firefox version 4.x. Workaround: Use Mozilla Firefox version 3.6. • [Ref. #21437] When a system takeover is performed, the redundant unit will be missing the Data Management Tool tables, if any, from the main system. The DMT tables are also missing when a system is restored from backup.
Release Notes Redundancy / Failover 1. Perform a takeover of a Main Application Server running CentOS by the Backup Application Server. 2. Reverse the takeover. 3. Perform a takeover of another Main running Red Hat Linux 9 by the Backup Application Server.
iControl Release Notes • [Ref. #24597] If an Application Server (whose iControl services are initially online) is added to an existing redundancy group in the role of Backup, the iControl services of this new Backup Application Server continue to run after the server has been added to the group. Workaround: Before adding an Application Server to a redundancy group as a Backup, make sure you stop iControl services first. • [Ref.
Release Notes Router Control • [Ref. #23109] After downgrading from iControl version 3.50 to an earlier version, if you attempt to upgrade back to iControl version 3.50, the upgrade may not work. Workaround: Contact Miranda Technical Support (see "Contact Us", on page 69). • [Ref.
iControl Release Notes lack of status, and, in the case of the Matrix view, a 16 × 16 matrix size not matching the actual device’s configuration. Workaround: Make sure you choose unique router names. • [Ref. #24675] When configuring a logical router in Router Manager Configurator, the Auto update labels check box on both the Source mapping and Destination mapping tabs may not be visible.
Release Notes SNMP Drivers Note: This and other issues can be avoided by observing proper syntax when creating host names. Please refer to Restrictions on valid host names at http://en.wikipedia.org/wiki/Hostname. SNMP Drivers • [Ref. #31469] When iControl is connected to a large Kaleido system, using the Kaleido-X SNMP plug-in to retrieve alarms may cause system performance issues as well as an Out of Memory error.
iControl Release Notes input in iControl version 3.10 and later requires firmware version 2.6 on the MTM400. Please contact support@miranda.com for more information. • [Ref. #18784] When upgrading from iControl version 3.20 (and later) to a newer version, the existing WidgetLibrary is renamed WidgetLibraryOld, and a new, upgraded WidgetLibrary is installed. Custom widgets that had been saved in the old WidgetLibrary become unavailable in iC Creator.
Release Notes Densité Series Cards Latest Densité card firmware versions supported by iControl (Continued) Card Model Firmware Version Introduced in iControl ADX-1141 1.0.6 3.20 or earlier ADX-1841 ADX-1842 3.20 or earlier 3.0.5 ADX-1851 60 3.20 or earlier 3.20 or earlier ADX-1852 3.0.5 3.20 or earlier ADX-1881 1.2.1 3.20 or earlier ADX-3981 2.0.1 3.60 AMX-1121 1.0.6 3.20 or earlier AMX-1141 1.0.6 3.20 or earlier AMX-1841 2.0.7 3.20 or earlier AMX-1842 2.0.9 3.
iControl Release Notes Latest Densité card firmware versions supported by iControl (Continued) Card Model Firmware Version Introduced in iControl EAP-3101 2.0.1 3.70 EAP-3901 2.0.1 3.70 ENC-1101 2.0.2 3.20 or earlier ENC-1103 1.0.2 3.20 or earlier FIO-901 1.0.3 4.40 FIO-1811 1.0.2 3.20 or earlier FIO-1821 1.0.2 3.20 or earlier FIO-1831 1.0.2 3.20 or earlier FIO-1841 1.0.3 3.20 or earlier FIO-1901-RR 1.0.2 3.70 FIO-1901-TT 1.0.2 3.70 FIO-1901-RT 1.0.2 3.
Release Notes Densité Series Cards Latest Densité card firmware versions supported by iControl (Continued) Card Model Firmware Version HDA-1841 3.20 or earlier HDA-1911 1.0.6 3.22 HDA-1931 1.0.6 3.22 HDC-1801 1.1.2 3.20 or earlier HDC-1861 1.1.2 3.20 or earlier HLP-1801 1.0.2 3.50 HMP-1801 5.0.1 3.21 HRS-1801-IN 1.0.1 3.22 HRS-1801-OUT 1.1.6 3.22 IRD-3101 3.2.4 4.00 IRD-3111 3.2.4 4.00 IRD-3801 3.2.3 3.21 IRD-3802 3.2.3 3.20 or earlier IRD-3811 3.2.3 3.
iControl Release Notes Latest Densité card firmware versions supported by iControl (Continued) Card Model Firmware Version SDM-1151 Introduced in iControl 3.20 or earlier SME-3101 1.0.2 3.50 SPG-1801 1.0.2 3.20 or earlier UAP-1781 3.1.0 3.20 or earlier UAP-1781 3.1.0 3.20 or earlier UAP-1783 1.0.2 3.20 or earlier VCP-1021 3.0.1 3.20 or earlier VDA-1001 3.20 or earlier VDA-1002 1.1.1 3.20 or earlier VEA-1001 3.20 or earlier VEA-1002 3.21 VEA-1021 3.20 or earlier VEA-1023 1.
Release Notes SNMP Devices Router protocols supported by iControl Router Manager (Continued) Company Protocol Typically used with Miranda Densité HRS-1801 Densité HCO-1801 NVISION Ethernet protocol - Enterprise router NV9000 system controllers NVISION Ethernet protocol - Compact router Compact router series CPU Link Protocol No.
iControl Release Notes Devices supported by iControl through SNMP (Continued) Manufacturer Device CrystalVision CrystalVision 2000 (IC-SNMP-021) Davicom Mac Plus (IC-SNMP-001) Ensemble Designs Avenue Evertz 500FC 3000 MVP 7700 Series Modular Video and Audio Interfaces (IC-SNMP- 002) Grass Valley (Thomson) Jupiter VM-3000 SMS-7000 Granite Sentinel Remote MPEG-2 QoS Monitor Triton Harmonic MaxLINK HOA 8030 (IC-SNMP-029) NMX IETF HOST-RESOURCES MIB Internet Control Message Protocol (ICMP) MIB-I
Release Notes SNMP Devices Devices supported by iControl through SNMP (Continued) Manufacturer Device Motorola DM-6400 CherryPicker (Terayon) DSR-4410, DSR-4500X (IC-SNMP-022), DSR-4520X (IC-SNMP-017/IC-SNMP-041) HDD-1100 Lifenet C6BD (IC-SNMP-025) Lifenet C8M MBT5000 (IC-SNMP-008) OM-1000 (IC-SNMP-103/IC-SNMP-043) SE-2000 (IC-SNMP-006) SE-4000/4010 SE-1010/2000/2000IP SE-5000/5010 SE-6000 SmartStream Encryptor/Modulator SEM (IC-SNMP-009) SmartStream Transport Multiplexer TMX 2010 (IC-SNMP-007) NVISION
iControl Release Notes Devices supported by iControl through SNMP (Continued) Manufacturer Device Sencore MRD 3187A SkyStream (Tandberg) iPlex Mediaplex-20 Snell (Pro-Bel) see Routers (IC-SNMP-027) Snell (Snell & Wilcox) IQ and RollCall (IC-SNMP-028) Tandberg nCompass RX1290 TT1260/1280 (IC-SNMP-005) TT4130 Tektronix MTM-400 WVR 611A WVR7100 Terayon (Motorola) CP 7585 Dual 8VSB to ASI Demodulator CP 7600 Multichannel Integrated Decoder (MID) (IC-SNMP-102/IC-SNMP-036) DM6400 (CherryPicker) T
Release Notes Non-SNMP Devices Devices supported by iControl through means other than SNMP (Continued) Manufacturer Device Name Thales/Thomson Granite Sentinel TSL SC -11 (serial control) Wegener Unity 4422 Broadcast Receiver (serial control) DTV720 Transport Stream Multiplexer Unity 4600 Professional Media Receiver (serial control) 68
Contact Us Miranda Technical Support For technical assistance, please contact the Miranda Technical Support center nearest you: Americas Office hours: Telephone: Fax: E-mail: Asia 9:00 a.m. - 9:00 p.m. (EST) 1-800-224-7882 +1 514 335 1614 support@miranda.com Office hours: Telephone: Fax: E-mail: Europe, Middle East, Africa, UK China Office hours: Telephone: Fax: E-mail: Telephone: E-mail: 9:00 a.m. - 6:00 p.m. (GMT) + 44 118 952 3444 + 44 118 952 3401 asiatech@miranda.
Contact Us 70