Maintenance and Troubleshooting
Maintenance and Troubleshooting
This section covers troubleshooting for the MICOM-2ET-RDP suitcase. Refer to
pages 132-136 of the MICOM-2E/2R for radio troubleshooting and error messages.
Preventative Maintenance of the Radio
System Integrity
Periodically check the integrity of your system, by examining the power source,
cables, coaxes, connectors, antenna tuner (if used) and antenna. Carefully check
that no damage has been caused to your cables, pay extra attention to runway
through holes and bent cables.
Periodic Calibration
To maintain the frequency accuracy of your radio, the internal frequency source
must be calibrated after 3, 6 and 12 months of operation in the first year, and once
a year thereafter. Please ensure that your radio is calibrated on time.
Using BITE
Every time the radio is turned on, a self-test procedure is activated. If an internal
malfunction is found, an error message will be displayed. Please contact your
service representative and report the indicated malfunction or error. A list of
possible error messages is given on page 132 of the MICOM-2E/2R User’s Guide.
Troubleshooting
If the MICOM-2ET-RDP is malfunctioning, try to solve the problem as follows:
Problem Troubleshooting
Blank Display
Check whether:
DC and/or AC power cables are connected properly.
The 30A fuse installed in the fuse holder located on the red wire
of the DC power cable is good.
The 6.3A fuse installed on the right side of the MICOM-2ET-
RDP connections box, next to the AC connection, is good.