Field Service Manual Basic and Field Level Test Procedures iDEN 870 Digital Multi-Service, Data-Capable Portable
i870 Digital Multi-Service, Data-Capable Portable Field Service Manual Basic and Field Level Test Procedures September 13, 2005 68P80401P01-O i
Manual Revisions Changes that occur after this manual is printed are described in the Field Manual Revisions (FMRs). The FMRs provide the most current instructions and component information. Copyright Information The Motorola products described in this manual may include Motorola computer programs stored in semiconductor memories or other media that are copyrighted with all rights reserved worldwide to Motorola. Laws in the United States and other countries preserve for Motorola, Inc.
SAFETY AND GENERAL INFORMATION IMPORTANT INFORMATION ON SAFE AND EFFICIENT OPERATION. READ THIS INFORMATION BEFORE USING YOUR INTEGRATED MULTI-SERVICE PORTABLE RADIO.
SAFETY AND GENERAL INFORMATION ALL MODELS WITH FCC ID AZ489FT5846 MEET THE GOVERNMENT’S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES. Your wireless phone is a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radiofrequency (RF) energy set by the Federal Communications Commission of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population.
SAFETY AND GENERAL INFORMATION P Operational Warnings F Operational Cautions For Vehicles Equipped with an Air Bag Antennas Do not place a portable radio product in the area over the air bag or in the air bag deployment area. Air bags inflate with great force. If a portable radio is placed in the air bag deployment area and the air bag inflates, the radio product may be propelled with great force and cause serious injury to occupants of the vehicle.
SAFETY AND GENERAL INFORMATION • Use of a non-recommended attachment to a battery charger may result in a risk of fire, electric shock, or injury to persons. • Make sure the battery charger power cord is located so that it will not be stepped on, tripped over, or subjected to damage or stress. • An extension cord should not be used with any battery • Do not disassemble a battery charger; take it to a qualified service technician when service or repair is required.
MODEL INFORMATION MODEL INFORMATION This manual applies to the following iDEN i870 Digital Portable models: H85XAH6RR5AN 806-940 MHz, Multi-Service, Data-Capable Portable MODEL NUMBERING SYSTEM Typical Model Number: Position: H 1 8 2 5 3 X 4 A 5 N 6 6 7 R 8 R 5 A N 9 10 11 12 Position 1 - Type of Unit H = Hand-Held Portable M = Mobile Product Positions 2 and 3 - Model Series Position 12 - Unique 40 = i85s/i55sr/i50sx Products 41 = i90c Products 45 = i265 Products 48 = i80s Products 56 = i30sx/
MODEL SPECIFICATIONS MODEL SPECIFICATIONS GENERAL FCC Designation: Operational Modes: 800 MHz Band only: Temperature Range: Operating Storage (w/o battery) Power Supply: Battery Type Recommended Battery: Battery Voltage: Nominal Range Dimensions (HxWxD): w/750mAh battery door w/500mAh battery door Weight: (without battery) RECEIVER AZ489FT5846 Receiver Type: Phone Frequency Range: Private Group Circuit Data Packet Data Channel Spacing: TRANSMITTER Direct Transmitter Type Conversion 851-870 MHz Freque
CONTENTS CHAPTER 1 SAFETY AND GENERAL INFORMATION . . . . . . . iii MODEL INFORMATION . . . . . . . . . . . . . . . . . . . . . vii MODEL SPECIFICATIONS. . . . . . . . . . . . . . . . . . . viii CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix PREFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii Who Should Use This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How This Manual Is Organized . . . . . . . . . . . . . .
CONTENTS Self-Test Reset Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHAPTER 4 CHAPTER 5 3-2 3-3 Alert Tones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the Optional Vibrate Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONTENTS Codeplug Help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9 Codeplug Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10 CHAPTER 7 PREPARING FOR FIELD LEVEL TESTING. . . . . 7-1 Preparing Equipment for Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 7-1 7-1 7-1 7-1 Calibrating Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONTENTS CHAPTER 9 MECHANICAL PARTS REPAIR PROCEDURES. . Recommended Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Recommended Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Recommended Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rework/Repair Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical Parts Rework . . . .
PREFACE The iDEN i870 Digital Multi-Service, Data-Capable Portable Field Service Manual contains the information necessary to identify and fix problems in the Motorola i870 Digital Portable. This unit is based on digital technology and is designed to operate on iDEN systems. Basic and field-level service for the this unit as described in this manual includes troubleshooting, testing, board swapping, and maintenance.
PREFACE: Conventions Used in This Manual 1.3 Conventions Used in This Manual The following conventions are used throughout this manual: italics bold code 1.
CHAPTER 1 OVERVIEW To achieve a high spectrum efficiency, the i870 digital multi-service, data-capable portable uses a unique modulation technology and sophisticated voice-compression algorithm. The voice of the person speaking into the microphone is converted into a digital bit stream consisting of zeros (0) and ones (1). The stream then is modulated into a radio-frequency (RF) signal, which is transmitted over the air to another unit. This process is called digital modulation. 1.
OVERVIEW: iDEN Digital Modulation Technology RL 0dBm 10 dB/ -10 -20 -30 Power -40 (dB) -50 -60 -70 -20 -10 0 10 20 Frequency from Desired Channel Center (kHz) Figure 1-1. Spectrum of iDEN Quad 16QAM Quadrature Phase Shift Keying (QPSK) is one of the most common modulation techniques for satellite communications. In QPSK, a digital data stream is taken two bits at a time to generate four possible phase states of the transmitted carrier. A characteristic of this technique is its resistance to noise.
OVERVIEW: iDEN Voice Compression Technology algorithms and one digital-signal processor (DSP) to perform voice compression/decompression and RF modulation/demodulation. Base Station Control Channel Transmitting 6 of 6 slots continually.
OVERVIEW: iDEN Voice Compression Technology (GPS) system. Each burst is numbered; the number is referred to as the slot number. All bursts occurring at a given time carry the same slot number. Inbound transmission bursts (sent from the unit) are offset 19 milliseconds from the outbound burst; the inbound burst begins 4 milliseconds after the end of the outbound burst (see Figure 1-2 on page 1-3).
OVERVIEW: Global Positioning System (GPS) Section 1.3 Global Positioning System (GPS) Section The U.S. Department of Defense (DoD) has built a 24-satellite constellation for the purpose of pinpointing locations anywhere on the planet. The satellites circle the earth every 12 hours, transmitting radio signals at a fixed frequency of 1575.42 MHz. The satellites share the 1575.42 MHz spectrum with each other through the use of CDMA modulation.
OVERVIEW: SIM Cards 1.6 SIM Cards This unit is designed to work with a mini Subscriber Identity Module (SIM). The SIM card contains all of the personal data required to access iDEN services. Data held by the SIM card includes: • • • • Temporary Mobile Subscriber Identity Services to which the user subscribes PIN and unblocking codes Call barring codes The SIM card is also capable of storing phone numbers and names. Available SIM cards for this unit are 64 kB and prepaid. 1.6.
OVERVIEW: SIM Cards Figure 1-3. Removing a SIM Card Figure 1-4. Inserting a SIM Card To insert a SIM card (Figure 1-4): 1. Open the SIM card holder. 2. Carefully slide the SIM card into the holder (see Figure 1-4). Position SIM card as shown. 3. Close SIM door, slide latch to shut. 4. Reinstall the battery, and reattach the battery cover.
This page intentionally left blank.
CHAPTER 2 FEATURES, ICONS, AND INDICATORS To conduct basic troubleshooting and maintenance of the i870 unit, you must become familiar with the components, display icons, and status indicators associated with the unit. 2.
FEATURES, ICONS, AND INDICATORS: Display Icons 2.2 Display Icons . Icons for the i870 provide information that is useful for troubleshooting and testing purposes. All features can be accessed through the main menu. When using a feature, the icon for that feature appears in the upper left corner of the display. Depending upon features and options chosen, the following icons can appear on the unit’s display. NOTE: Feature icons may appear in various places within the display.
FEATURES, ICONS, AND INDICATORS: Display Icons 2.2.2 Status Icons Status icons appear in the two rows at the top of the display. Some appear at all times. Others appear only when your phone is engaged in certain activities or when you have activated certain features. Battery Strength—Indicates the battery’s stored level of charge. The Battery Strength icon exhibits a darkened area inside the simulated battery image to indicate the level of stored charge.
FEATURES, ICONS, AND INDICATORS: Display Icons This page intentionally left blank.
CHAPTER 3 DISPLAYS, MESSAGES, AND ALERTS 3.1 Power-Up Sequence Extend the antenna whip and press the Power key until the power-up sequence begins. NOTE: Pressing the Power key for more than 5 seconds turns on Airplane mode. When the unit is in Airplane mode, it cannot make or receive phone calls, Private calls, or group calls; or transfer data. Bluetooth capability is disabled, and all active Bluetooth connections are dropped. The power-up sequence initiates a series of displays on the unit.
DISPLAYS, MESSAGES, AND ALERTS: Power-Down Sequence 3.2 Power-Down Sequence To power down the unit, press and hold the Power key until the unit begins powering down. 3.3 Messages 3.3.1 Self-Test Errors The following table contains the list of self-test non-reset errors. These errors are displayed as SELF CHECK ERROR YXXXX (YXXXX represents the identifier for that error). Table 3-1. Self-Test Errors 3.3.
DISPLAYS, MESSAGES, AND ALERTS: Messages 3.3.3 Service Messages Service messages indicate the probable cause of a problem. The following table lists the messages, their probable causes, and recommended corrective actions. Table 3-3. Service Messages Message Cause Action Charger Attached While Power Down Device Attached 17-Pin connector plugged in while powered up. Device Detached 17-Pin connector removed while powered up.
DISPLAYS, MESSAGES, AND ALERTS: Alert Tones Table 3-4. Bluetooth® Service Messages 3.4 Status Message Message Description No Devices Found No devices were found during your Bluetooth search. Bluetooth Link Is Busy A Bluetooth error occurred. Please try again. Invalid PIN The incorrect PIN for the given Bluetooth device was entered. Please try again. Bluetooth Power Failed An error occurred with Bluetooth power. Please try again.
DISPLAYS, MESSAGES, AND ALERTS: Alert Tones Table 3-5. Alert Tones (Continued) Tone Low High Freq Cadence When Tone Occurs Data Ringer Ear Spkr 2091/ 2823Hz 14x (80ms on 2091Hz + 100ms on 2823Hz + 2.
DISPLAYS, MESSAGES, AND ALERTS: Alert Tones Table 3-5. Alert Tones (Continued) Tone Low High Phone Ring (U.S.) Spkr Spkr Freq Cadence When Tone Occurs Available ringer tones: 14x(24ms on 2091Hz + 24ms on 2556Hz) + 2.5s off Phone call received 2091/ 2556Hz 2230/ 2040Hz 14x(64ms on 2230Hz + 64ms on 2040Hz) + 2.5s off 2310/ 2820Hz 3x(400ms on 2310Hz + 400ms on 2820Hz) + 2.5s off 3240/ 2140Hz 14x(38ms on 3240Hz + 38ms on 2140Hz) + 2.
DISPLAYS, MESSAGES, AND ALERTS: Using the Optional Vibrate Function Table 3-5. Alert Tones (Continued) Tone Low High Freq Cadence When Tone Occurs Voice Mail Received in Idle Spkr Spkr 2400/ 2743Hz 8x(64ms on 2400Hz + 64ms on 2743Hz) every 30 seconds Voice mail received while unit is idle Voice Mail Received in Interconnect Ear Ear 2400/ 2743Hz 8x(64ms on 2400Hz + 64ms on 2743Hz) every 30 seconds Voice mail received while unit is in interconnect mode 3.
This page intentionally left blank.
CHAPTER 4 PREPARING FOR BASIC LEVEL TESTING 4.1 Test Equipment The following equipment is useful when testing an i870 unit: a reference unit, a reference SIM card, and reference accessories. For a list of recommended test and programming equipment used to troubleshoot this unit, see Appendix A: Ordering Replacement Parts and Kits. 4.1.1 Reference Unit Use a reference unit (i870 unit known to be in good working order) to verify the accuracy of some tests.
This page intentionally left blank.
CHAPTER 5 BASIC LEVEL CHECKS AND SELF TESTS Before you perform basic troubleshooting and self tests on an i870 unit, determine if any special conditions could affect testing and check the units for defective parts. There are five categories of basic tests: • • • • Preventive maintenance Mechanical/electrical checks Self tests Technician tests Test procedures are listed in the order in which they should be implemented.
BASIC LEVEL CHECKS AND SELF TESTS: Basic-Level Test Checklist 5.3 Basic-Level Test Checklist Use the following checklist to ensure that all the necessary tests are performed and to provide a tracking mechanism in case the unit is sent to the next level of service. Check the appropriate box for each test performed and indicate whether or not the test was completed successfully. Table 5-1.
BASIC LEVEL CHECKS AND SELF TESTS: Mechanical and Electrical Checks 4. Wipe and dry the unit with a soft, absorbent, lint-free cloth. Make sure that there are no damp spots on the connectors or in cracks and crevices. 5.5 Mechanical and Electrical Checks Before conducting more complex tests, clean and check the unit for any mechanical defects that might cause or contribute to the problem.
BASIC LEVEL CHECKS AND SELF TESTS: Mechanical and Electrical Checks 5.5.1 SIM Card Swap Test Use this test to determine if the SIM card is defective, or if the unit is defective. The SIM Card Swap test time is approximately 5 minutes: 1. Power off the unit, and then remove the battery. 2. Remove the SIM card from the unit. 3. Clean the SIM card, if necessary, by wiping its surfaces with a clean, static-free cloth, and then check the contact areas in the unit for foreign material, damage, or other defects.
BASIC LEVEL CHECKS AND SELF TESTS: Mechanical and Electrical Checks 5.5.3 Lockup Test Use this test to determine if the unit locks up when keys are pressed or when it is powered down. The Lockup Test time is approximately 6 minutes: 1. Power up the unit. 2. Press End Call to clear display inputs. 3. Press each of the alphanumeric keys to see if the unit responds. If the unit does not respond to a pressed key, remove the battery to cycle power on.
BASIC LEVEL CHECKS AND SELF TESTS: Mechanical and Electrical Checks To test the GPS Receiver: 1. Move the unit to an open sky area, preferably outside—away from tall buildings and foliage. 2. With the unit turned on, press Menu. 3. Scroll until the GPS menu option is highlighted. 4. Press SELECT. 5. Scroll down on the GPS menu until the “POSITION” option is selected. 6. Press SELECT. The unit will display a “Position” information sheet. 7. Press RFRSH.
BASIC LEVEL CHECKS AND SELF TESTS: Mechanical and Electrical Checks If this test is successful, place the unit’s battery in the reference unit and re-run the test. 5.5.7 Camera Test 1. Enter the MA (Model Assembly) Mode. Press and hold three number keys simultaneously with the Power key, such as 1-2-3, 4-5-6, 7-8-9. 2. Scroll the display to Camera View Finder. Ensure that the camera lens is clean and not damaged. 3. Verify that the viewfinder shows the captured image correctly.
BASIC LEVEL CHECKS AND SELF TESTS: Self-Test Procedures 3. If prompted whether you want to bond with the device, press the Option key under Yes. 4. If prompted, enter the Bluetooth PIN. Your phone will connect to the device. 5.6 Self-Test Procedures An i870 unit allows you to conduct automatic self tests to ensure that it is working properly. Selftest procedures include gathering information from the unit’s displays and testing the functionality of basic components.
BASIC LEVEL CHECKS AND SELF TESTS: Self-Test Procedures • Text Size — User can select displayed text size. Settings > Display/Info > Text Size > OK. • Theme — Sets various background images. Settings > Display/Info > Theme > OK. • Home Icons — When activated, displays Shortcut Icons on the idle screen. Settings > Display/Info > Home Icons > OK. • Backlight — controls how long backlight stays on after you make or receive a call. The backlight will go to 1/4 brightness after 10 seconds.
BASIC LEVEL CHECKS AND SELF TESTS: Self-Test Procedures • TTY — lets you use your phone with a TTY device. To use your phone to make phone calls using a teletypewriter (TTY) device: 1. 2. 3. • Connect one end of a 2.5 mm cable into the audio jack on your phone. Connect the other end of the cable to your TTY device. Make sure that your phone’s TTY feature is on and select the TTY mode you want to use. Use your phone to enter phone numbers and make calls.
BASIC LEVEL CHECKS AND SELF TESTS: Self-Test Procedures 4. • Press the Ok button to Select. If your phone does not include a vibrate feature, you can still set your phone make no sound. Scroll to Silent in step 3. PTV — Push To View. Enables sending or receiving pictures during private calls. Select On or Off. Personalize • Menu Options — User can reorder menu items and add/remove stored applications. Settings > Personalize> Menu Options > OK > Reorder Menu.
BASIC LEVEL CHECKS AND SELF TESTS: Self-Test Procedures • Data — sets the volume of sounds that notify you that you are receiving a circuit data call. Security Features The Security menu lets you turn security features on and off and change passwords: • Phone Lock — turns on a feature that locks your phone, either immediately or automatically after a set period of inactivity. An unlock code is required to enable this feature, to unlock the phone, and to set a new Unlock code.
BASIC LEVEL CHECKS AND SELF TESTS: Self-Test Procedures To change your GPS PIN: • 1. 2. From the main menu, select Settings > Security > Change Password > GPS PIN. Enter the current GPS PIN. 3. 4. 5. 6. 7. Note: When you receive your phone, your GPS PIN is 0000. Press the Ok button. Enter the new 4- to 8-digit GPS PIN. Press the Ok button. Enter the new 4- to 8-digit GPS PIN to confirm. Press the Ok button. Change Password — changes your phone unlock code, security code SIM PIN, and GPS PIN.
BASIC LEVEL CHECKS AND SELF TESTS: Self-Test Procedures 5.6.3 Call Performance Test Use this test to verify the unit’s ability to complete interconnect and dispatch calls. NOTE: To prevent FM noise interference during testing, be sure to separate the test units by an appropriate distance. Required equipment: reference unit The Call Performance test time is approximately 7 minutes: 1. Power up the unit. Wait until registration is complete before continuing. 2.
CHAPTER 6 BASIC LEVEL TEST MODES AND PROCEDURES To complete basic testing of an i870 unit, you must enter a test mode to retrieve data from the unit, and perform the technician tests in the correct sequence with the appropriate equipment. Test procedures are listed in the order in which they should be implemented. Each test contains a description of what it does, the approximate time needed to perform it, and the type of equipment required (if any).
BASIC LEVEL TEST MODES AND PROCEDURES: Test Modes 6.1.2 Trace Mode Display Screens Display screens on this unit provide information that is useful for troubleshooting purposes. These displays appear only when the unit is placed in Debug Mode (see “Entering Debug Mode” on page 6-1). To navigate through the screens, press the appropriate scroll key to highlight the desired screen, and then press the View option key. To select a choice within a screen, press the Select option key.
BASIC LEVEL TEST MODES AND PROCEDURES: Test Modes Table 6-1. Display Screens (Continued) 6.1.3 Name Description IMEI/SIM ID/SN Displays the electronic serial number, SIM ID serial number, and unit serial number. The IMEI is the global name assigned to the mobile station at manufacturing time and should correspond to the serial-number tag of the unit. The SIM ID is the SIM electronic serial number and should correspond with the number stamped on the SIM card. The SN is applied during manufacturing.
BASIC LEVEL TEST MODES AND PROCEDURES: Test Mode Test Procedures 4. Press Menu key three times. 5. Press the left Scroll key. 6. Press Menu key twice. 7. Press the left Scroll key. You are now in Test Mode. To exit Test Mode, press the option key under Exit. The unit waits for a few seconds, resets, and then re-registers the unit. 6.2 Test Mode Test Procedures Enter Debug or Test Mode to perform the following tests: • • • 6.2.
BASIC LEVEL TEST MODES AND PROCEDURES: Test Mode Test Procedures 6.2.2 ESN and IMEI Matching Test Use this test to verify that the electronic serial number (ESN) matches the International Mobile Equipment Identifier (IMEI) on the Serial Number label located on the chassis of the unit. The ESN/IMEI Matching test time is approximately 6 minutes: 1. Power up the unit. Wait until the power-up sequence is complete before continuing. 2. Enter Debug Mode. The Unit Info display appears. 3.
BASIC LEVEL TEST MODES AND PROCEDURES: Test Mode Test Procedures f. Press Back to return to the Unit Info display, and then scroll down to highlight the Software choice. g. Press Select to view the current software version programmed in the unit, as well as the software type (RSS model) and build date. 3. Press Back twice to return to the Trace Mode display. 4. Scroll down to highlight Total Usage, and then press View to view the Total Usage display.
BASIC LEVEL TEST MODES AND PROCEDURES: Test Mode Test Procedures 14. Scroll down to highlight IMEI/SIM ID, and then press View to view the IMEI/SIM ID display. The IMEI is the global name assigned to the mobile station at manufacturing time and should correspond to the serial-number tag of the unit. The SIM ID is the SIM electronic serial number and should correspond with the number stamped on the SIM card. 15. Press Back to return to the Trace Mode display. 16.
BASIC LEVEL TEST MODES AND PROCEDURES: Technician Test Procedures 31. Press Back to return to the Trace Mode display. 32. Scroll down to highlight Flags, and then press View to view the Flags display. This screen displays the error log, which contains any errors logged by the unit software. 33. Press Back to return to the Trace Mode display. 34. Scroll down to highlight Coin Cell, and then press View to show the Preset Charging Voltage on line 1 and Current Battery Voltage on line 2. 35.
BASIC LEVEL TEST MODES AND PROCEDURES: Connecting the Unit to the RSS Workstation To connect the unit to a PC using the iDEN RS-232 (serial) or USB data cable (Figure 6-1): 1. Insert the 17-pin connector on the data cable to the 17-pin connector located at the base of the unit. 2. Attach the other end of the data cable to the RS-232 port or USB port on the RSS computer workstation that is used for testing purposes. Figure 6-1.
BASIC LEVEL TEST MODES AND PROCEDURES: Connecting the Unit to the RSS Workstation Equipment Required: Computer workstation with RSS installed, data cable RS232 or USB, reference unit (must be the same model as the problem unit). To access the codeplug Help topic in Windows: 1. Set up your test equipment configuration. See Figure 6-1 for an illustration of this configuration. 2. Start the RSS program. 3. Click on the Help choice on the menu bar, and then select Contents. The RSS online Help is displayed. 4.
CHAPTER 7 PREPARING FOR FIELD LEVEL TESTING Field level testing requires external equipment and support. To conduct field level troubleshooting and testing of an i870 unit, you must become familiar with the screen readouts of the recommended test equipment. Display screens provide information that is useful for troubleshooting purposes. Refer to Chapter 3 for information on the displays, errors, alert tones, and messages associated with this unit. 7.
PREPARING FOR FIELD LEVEL TESTING: Using RSS • • • Wear a conductive wrist strap in series with a 100 kΩ resistor to ground. Do not wear nylon clothing when handling any printed-circuit board. Prior to touching any printed-circuit board, touch an electrical ground to remove any static charge that might have accumulated. Refer to Service and Repair Note SRN-F1052 for more information.
PREPARING FOR FIELD LEVEL TESTING: Connecting an iDEN Unit to the R-2660 Figure 7-1. Typical R-2660 Setup To connect the unit to the R-2660: 1. Ensure the unit is powered off, and then turn on the R-2660. 2. Remove the battery cover and battery from the unit, and insert the reference SIM card. 3. Attach the battery eliminator to the back of the unit. 4. Engage RF. 5. Connect the SMA connector of the RF cable to the RF connector on the battery eliminator. 6.
PREPARING FOR FIELD LEVEL TESTING: Operating the R-2660 10. Power up the subject unit. Refer to the R-2660 Digital Communications System Analyzer Operator’s Manual for more information on how to use this equipment. 7.4 Operating the R-2660 Most of the technician tests performed with the R-2660 Communications System Analyzer require that the analyzer use the Initial Registration test mode. To enter Initial Registration mode: 1. Turn on the R-2660. 2.
PREPARING FOR FIELD LEVEL TESTING: Disassembling and Reassembling the Unit 7.2 Disassembling and Reassembling the Unit Motorola recommends the service technician follow a prescribed disassembly sequence to access specific items or components of the unit. This product is an efficiently designed package that incorporates the physical overlap and integration of some modular components. Refer to the Disassembly Sequence flowchart for a suggested path to reach specific components.
PREPARING FOR FIELD LEVEL TESTING: Battery Cover 7.5 Battery Cover 7.5.1 Remove: 1. Place thumb or fingernail against release latch (see Figure 7-2). 2. Push button down until cover releases. Pull bottom of cover away slightly. 3. Push cover up to release from top clip. 7.5.2 Install: 1. Bring top clip of cover into its respective slot. 2. Push top of cover down. Press bottom of cover until release latch fully snaps into place. Release Latch Figure 7-2. 7.
PREPARING FOR FIELD LEVEL TESTING: Antenna 7.7 Antenna Required Tools: T-4 Torx bit. 7.7.1 Remove: 1. Remove battery cover. Locate T4 screw head at base of antenna (see Figure7-3). 2. Loosen T-4 counterclockwise. Remove completely. Screw Head 3. Extend antenna whip fully. 4. Hold unit stationary while pulling at antenna collar until antenna assembly releases. 7.7.2 Install: 1. Insert antenna assembly with whip fully extended. 2. Check that the antenna contacts are toward interior of unit.
PREPARING FOR FIELD LEVEL TESTING: Back Housing 7.8 Back Housing Required Tools: T-6 Torx bit, black stick. Preparation: Remove battery cover, extend antenna. Open audio jack seal, accessory connector seal, and memory card seal. 7.8.1 Remove: 1. Remove four T-6 screws—one in the antenna tube channel (see Figure 7-4). 2. Gently squeeze the front housing at the number 7 and 9 keys to separate the housing clips (see Figure 7-5). 3. Once the housings are free, do not stress flex strip near PTT key.
PREPARING FOR FIELD LEVEL TESTING: Back Housing Figure 7-5. Figure 7-6.
PREPARING FOR FIELD LEVEL TESTING: Main Board, Microphone Seal, and Keypad 7.9 Main Board, Microphone Seal, and Keypad Required Tools: Black stick. 7.9.1 Remove: 1. Wedge black stick under 50-pin flex connector. Gently pry upwards along length until release (see Figure 7-7). 2. Remove microphone seal by inserting point of black stick under seal skirt and gently prying up on seal perimeter Do not push microphone or nearby components (see Figure 7-8). 3.
PREPARING FOR FIELD LEVEL TESTING: Flip Assembly 7.10 Flip Assembly 7.10.1 Remove Flip Assembly: Required Tools: Black stick, dental pick, T4 Torx bit, hinge mechanism removal tool. NOTE: i870 flip components include a flex connector ribbon which can be easily torn or damaged if not handled with care. Exercise caution when sliding the flex ribbon through the front housing slot. Figure 7-10. 1. Remove the keypad and main board from the front housing. Make sure the flip is in the open position 2.
PREPARING FOR FIELD LEVEL TESTING: Flip Assembly 7. Once the flip assembly is free, feed the flex ribbon and connector carefully through the flex ribbon slot. Figure 7-13.
PREPARING FOR FIELD LEVEL TESTING: Flip Assembly 7.10.2 Install: Required Tools: T4 Torx bit, hinge mechanism install tool. Preparation: Check that the flip is in the open position. 1. Carefully guide the flex connector through opening in front housing. Do not bend or tear the flex ribbon. Align flip assembly to front housing with the flip in the open position. 2. Insert hinge mechanism into its pocket on the right side of flip.
PREPARING FOR FIELD LEVEL TESTING: Flip Assembly Figure 7-16.
PREPARING FOR FIELD LEVEL TESTING: Exploded Views and Parts Lists 7.11 Exploded Views and Parts Lists This section contains the component parts lists and exploded views for the i870 units.
PREPARING FOR FIELD LEVEL TESTING: Exploded Views and Parts Lists i870 Component Parts List 7-16 Item Description Part Number 1 Housing, Flip Front (Assembly) 1575133A01 2 Keypad, Generic Korean Hebrew Arabic International 7575126A01 7575126A02 7575126A03 7575126A04 7575126A05 3 Dome Array, Keypad (part of #4) 4075123A01 4 PCB, Main Assembly (including #3) 5 Back Housing Assembly (including #6 and #7) Reference Reference Only 1575124A01 6 Antenna 8575108A01 7 Screw, Antenna 0385693
PREPARING FOR FIELD LEVEL TESTING: Exploded Views and Parts Lists i870 Exploded View 68P80401P01-O 7-17
This page intentionally left blank.
CHAPTER 8 FIELD LEVEL TEST MODES AND PROCEDURES To perform field level testing on the i870 unit, you must enter a test mode to retrieve data from the unit, and perform the technician tests in the correct sequence with the appropriate equipment. NOTE: All tests should be performed in an RF interference-free environment. Test procedures are listed in the order in which they should be implemented. Each test contains a description of what it does and the type of equipment required (if any).
FIELD LEVEL TEST MODES AND PROCEDURES: Required Test Equipment The following tests are performed in Test Mode: • TX Power Test • BER Tests 800BER1 800BER2 800BER3 800BER4 900BER1 900BER2 900BER3 NOTE: The Power, MPX, and MOD test parameters are for factory use only and should not be adjusted by field service personnel. The default values for these parameters are as follows: 8.
FIELD LEVEL TEST MODES AND PROCEDURES: Field-Level Test Checklist 8.3 Field-Level Test Checklist Use the following test checklist to ensure that all the necessary tests are performed and to provide a tracking mechanism in case the unit is sent to the next level of service. Check the appropriate box for each test performed and indicate whether or not the test was completed successfully. Table 8-1.
FIELD LEVEL TEST MODES AND PROCEDURES: Registration/Call Test 8.4 Registration/Call Test Use this test on a unit having any of the following symptoms: No Service failures, Please Wait... Registering failures. (Use a reference unit to get a baseline.) Note: For 900 MHz verification, please perform the BER Test. May require ordering additional option for test. Contact Motorola Customer Service (see Appendix A). Set up the R-2660 for iDEN Mobile operation, and connect the unit to the RF IN/OUT connector.
FIELD LEVEL TEST MODES AND PROCEDURES: Signal Quality Error (SQE) Test 8.5 Signal Quality Error (SQE) Test Use this test on a unit having any of the following symptoms: No service failures or poor SQE/ RSSI (poor performance in known good coverage area). Set up the R-2660 for iDEN Mobile operation, and connect the unit to the RF IN/OUT connector. See Figure 7-1 on page 7-3. Connect the regulated battery eliminator to the unit to be tested. Remove the antenna from the unit. Set the power supply 4.0 Vdc.
FIELD LEVEL TEST MODES AND PROCEDURES: TX Power Test 8.6 TX Power Test Use this test on a unit on a unit having bad transmission (TX) or intermittent service failures. (This is a transmitter test only.) Set up the R-2660 for Spectrum Analyzer display, and connect the unit to the RF IN/OUT connector. Notes: 1. Place the unit into Test Mode for this test. 2. Unit will transmit at greater than 24 dBm. 3.
FIELD LEVEL TEST MODES AND PROCEDURES: Bit Error Rate (BER) Test 8.7 Bit Error Rate (BER) Test Use this test on a unit having any of the following symptoms: resets (RAAAA Type), No Service failures. Set up the R-2660 for iDEN BER Test, and connect the unit to the RF IN/OUT connector. Connect the battery eliminator to the unit. Remove the antenna. Set power supply between 5.0 and 12.0 Vdc. Notes: 1. 2. 3. 4. 5. 6. Confirm the reset log has errors. Place the unit into Test Mode for this test.
FIELD LEVEL TEST MODES AND PROCEDURES: Power-Up Test 8.8 Power-Up Test Use this test to check power-up. Symptoms: dead battery, short battery life, or unit does not power up. Try to power up the unit. Note: In the United States, the Main board can only be replaced and programmed at the factory or iDEN Radio Support Center. Pass Verify that the display pixels light up. Fail Swap the Display module and the Main board one at a time in that sequence until the display lights up.
FIELD LEVEL TEST MODES AND PROCEDURES: Keypad Test 8.9 Keypad Test Use this test to check the operation of the unit’s keypads and display. Symptoms: unit locked, or stuck key. Power up the unit. Enter the Model Assembly (MA) Test Mode. Verify that all the display tests complete correctly. Swap the Display module and the Main board one at a time in sequence until the display lights up.
FIELD LEVEL TEST MODES AND PROCEDURES: Audio Test 8.10 Audio Test Use this test to check the audio portion of the unit. Set up the R-2660 for iDEN Mobile operation, and connect the unit to the RF IN/OUT connector. Place an interconnect call. (See Registration/Call test.) Notes: 1. Verify that the unit can pass the SQE test before performing the Audio test. 2. This test checks outbound interconnect signals using the earpiece. Fail Perform Registration/Call troubleshooting procedure.
FIELD LEVEL TEST MODES AND PROCEDURES: Reset Test 8.11 Reset Test Use this test on a unit having any of the following symptoms: unit resets, or unit powers off and then on. Set up the R-2660 for iDEN Mobile operation, and connect the unit to the RF IN/OUT connector. Power up the unit. Enter Initial Registration mode (see Operating the R-2660). Notes: 1. Verify that the unit has resets entries in the Reset log. See the Reset Log Test. 2. Try to duplicate the failure. 3.
FIELD LEVEL TEST MODES AND PROCEDURES: Reset Log Test 8.12 Reset Log Test Use this test to check the reset log in the unit. To perform the reset log test: 1. Power on the unit and wait until registration is complete. 2. If the unit does not have the latest software version, reflash (reprogram) the unit. If the unit attempts to reset, perform the Reset test (see page 8-11). 3. Enter Trace Mode (see page 6-1). The Unit Info display appears. 4.
FIELD LEVEL TEST MODES AND PROCEDURES: Model Assembly (MA) Test Mode Test 8.
FIELD LEVEL TEST MODES AND PROCEDURES: GPS (Global Positioning System) Receiver Test 8.14 GPS (Global Positioning System) Receiver Test Use this test on a unit to check its GPS functionality. Find an open sky area. Extend antenna and power up unit. Obtain reference GPS receiver. Activate GPS Phone returns location coordinates ? Yes Location coordinates match reference ? Yes GPS working. No No GPS not working.
FIELD LEVEL TEST MODES AND PROCEDURES: Bluetooth Test 8.15 Bluetooth Test Use this test on a unit to check the functionality of the Bluetooth Headset. Obtain Motorola HS810 or HS820 Bluetooth Headset. Extend antenna and power up unit. Turn unit on. Bond with Bluetooth headset. Successful bond ? Yes Make phone call with Bluetooth headset Successful call ? Yes No No Bluetooth not working * Bluetooth is working.
FIELD LEVEL TEST MODES AND PROCEDURES: i870 Camera Test 8.16 i870 Camera Test Use this test to check camera module. Symptoms: Bad view finder (noise, poor color, synchronization error). Power up the unit. Enter the Model Assembly (MA) Test Mode. Verify that the viewfinder shows the captured image correctly. Pass Fail Replace Flip Assembly and repeat the test. Fail Pass Replace the main FPC and repeat the test. Fail Pass Unit passed test.
FIELD LEVEL TEST MODES AND PROCEDURES: MOTOtalk Test 8.17 MOTOtalk Test Perform BER Test and TX Power Test prior to the MOTOtalk Test. If these tests do not pass, replace the Main Board. Use the MOTOtalk Test to test MOTOtalk without test equipment. Perform the MOTOtalk Test with the golden radio as transmitter, determine pass or fail. Then, use the golden radio as receiver and determine pass or fail. Place radio under test and a golden radio into MOTOtalk Mode: 1. Menu 2. More 3. Down 4. Down 5.
This page intentionally left blank.
CHAPTER 9 MECHANICAL PARTS REWORK AND REPAIR The following section details the equipment and procedures needed to correctly remove and replace specific Main Board components on the i870. 9.1 Recommended Equipment 9.1.1 Hot Air Machine Pace ThermoFlo 200 or similar. 9.1.2 Pre-heater X-Kar 1000-S or similar. 9.1.3 High Performance Soldering Station Pace HeatWise 200 with thermal recovery system or similar. 1. .6mm (0.06”) CHISEL (P/N1124-0019-P1) to fill lands (Big) during Land Preparation procedure.
MECHANICAL PARTS REWORK AND REPAIR: Recommended Supplies • • • • • 9.2.2 Heat Shields • • • • • 9.2.3 N-P20 N-P32 N-P68 N-P84 N-Q1420 A F J I, and L (New) Tweezers Excelta 5CSAD or similar 9.2.4 Probe/Pick BeauTech 241 or similar 9.2.5 Vacuum Pick X-Kar XVP-200 or similar 9.3 Recommended Supplies Indium Indalloy NC771 flux pen (Motorola P/N 1185768C01) for rework of Bottom Connector, RF Connector and Switches 9.4 Rework/Repair Requirements: 9.4.1 Temperatures: • • • 9.4.
MECHANICAL PARTS REWORK AND REPAIR: Mechanical Parts Rework Procedure 9.4.3 Components Identification Battery Contacts Antenna Hot Contact SIM Contacts Audio Jack Accessory Connector 9.5 Mechanical Parts Rework Procedure 9.5.1 Removal Procedure 1. Set proper temperatures. 2. With bottom heater ON, place the assembly on top of it to start pre-heating the PCB. 3. Place adequate Nozzle in the hand-piece of the Hot Air Machine. 4. Set desired air pressure.
MECHANICAL PARTS REWORK AND REPAIR: Mechanical Parts Rework Procedure 5. Get the new component ready by fluxing it as per specifications. 6. Protect any heat-sensitive component by placing appropriate Heat Shield over (If necessary) 7. Lower the nozzle and evenly apply heat until reflow of all solder joints is observed. 8. Immediately remove component before solder joints re-solidifies. 9. Release faulty component onto a heat resistant surface. 10.
MECHANICAL PARTS REWORK AND REPAIR: Mechanical Parts Rework Procedure 9.5.4 J600 RF Connector Top 330ºC - Bottom 100ºC N-P07 OK Industries 151/min “F” over M105, and “F” over J600 during Installation Procedure. Pace 6/7 NOTE: Use Flux Pen Indium-Indalloy NC771 ONLY (Motorola P/N 1185768C01). Use flux sparingly. 9.5.5 J752 Audio Jack Top 330ºC - Bottom 100ºC N-P20 OK Industries 151/min Modified “F” over J752 during Installation Procedure. Pace 9.5.
MECHANICAL PARTS REWORK AND REPAIR: Mechanical Parts Rework Procedure 9.5.8 M002 (SIMM Connector) Top 330ºC - Bottom 100ºC N-P32 OK Industries 201/min “L” over M002 & J401 during Installation Procedure. Pace 9.5.9 8/9 M105 (Battery Contact) Top 330ºC - Bottom 100ºC N-P20 OK Industries 151/min “F” over J600 during Removal Procedure. Pace “F” over J600 & F over M105 during Installation Procedure. 6/7 9.5.
MECHANICAL PARTS REWORK AND REPAIR: Mechanical Parts Rework Procedure 9.5.12 SW-all (Key/Switch) Top 330ºC - Bottom 100ºC N-Q07 OK Industries 151/min “I” over nearby SW during Removal Procedure. Pace “I” over nearby SW & “I” over replaced SW during Installation Procedure. 6/7 NOTE: Use Flux Pen Indium-Indalloy NC771 ONLY (Motorola P/N 1185768C01). Use flux sparingly. NOTE: Always protect switches from heat and Flux intrusion to avoid component malfunction.
This page intentionally left blank.
APPENDIX A ORDERING REPLACEMENT PARTS AND KITS Parts should be replaced with identical replacement parts. Replacement parts and kits for i870 units can be ordered directly from the Motorola Accessories and Aftermarket Division (AAD) at 1-800-422-4210 and listen to the prompts; or FAX 800-622-6210. A.1 Customer Service For warranty and customer service assistance, call: 1-800-453-0920 U.S./Canada 1-954-723-3000 FAX 1-954-723-4910 International (outside U.S./Canada) A.
ORDERING REPLACEMENT PARTS AND KITS: Replacement Kits A.4 Replacement Kits When ordering replacement kits, the complete kit number should be included. If the correct kit number cannot be located, call Motorola Parts Identification at 1-800-422-4210. Refer to the exploded views and parts lists in Chapter 7. Table A-1. i870 Replacement Kits Description Kit Number Batteries: High Performance Battery SNN5705C Maximum Capacity Battery NNTN4655B Battery Doors: High Perf.
ORDERING REPLACEMENT PARTS AND KITS: Replacement Kits Table A-1.
ORDERING REPLACEMENT PARTS AND KITS: Recommended Test Equipment and Tools Table A-2. High Performance Battery Door w/Escutcheon Label Assembly Replacement Kits A.
ORDERING REPLACEMENT PARTS AND KITS: Recommended Programming Equipment A.6 Recommended Programming Equipment The following tables list the programming equipment and software recommended for troubleshooting i870 units at the field level of service. Table A-4. Recommended Programming Equipment Name Part Number Description Cable, Data, RS232 Cable, Data, USB NKN6560A NKN6559A Connects unit to the computer for monitoring the codeplug. Cable, Data (2.
This page intentionally left blank.
Motorola Confidential Proprietary © 2005 by Motorola, Inc. 8000 W. Sunrise Blvd. Ft. Lauderdale, FL 33322 Printed in U.S.A. 9/05. All Rights Reserved.