Service manual

BASIC LEVEL TEST MODES AND PROCEDURES: Test Mode Test Procedures
68P80401P01-O 6-5
6.2.2 ESN and IMEI Matching Test
Use this test to verify that the electronic serial number (ESN) matches the International
Mobile Equipment Identifier (IMEI) on the Serial Number label located on the chassis of the
unit.
The ESN/IMEI Matching test time is approximately 6 minutes:
1. Power up the unit. Wait until the power-up sequence is complete before continuing.
2. Enter Debug Mode. The Unit Info display appears.
3. Scroll down until the IMEI/SIM ID choice is highlighted, then press View to view the
IMEI/SIM ID display.
4. Write down the digits shown in the IMEI line.
5. Verify that this number matches the IMEI on the Serial Number label. The last zero on
the label will be missing.
If the numbers do not match, send the unit to the field level of service.
6.2.3 Debug Check
Use this check to monitor (measure) the data in an i870 unit.
NOTE: The following procedure describes the sequence of displays accessed via the down
scroll key. If you press the up scroll key, the sequence appears in reverse order.
To monitor the data in the unit:
1. Power up the unit. Wait until the power-up sequence is complete before continuing.
2. Enter Debug Mode. The Unit Info display appears.
a. Press View to view the Phone Model display, and then press Select to view the
phone model, such as i870.
b. Press Back to return to the Unit Info display, and then scroll down (down scroll key)
to highlight the CP Ver choice.
c. Press Select to view the Codeplug Version. The first half of the line displays the
codeplug structure and default version; the second half displays the codeplug
bandmap.
d. Press Back to return to the Unit Info display, and then scroll down to highlight the
CSD Ver choice.
e. Press Select to view the Customer Static Data version. The first number indicates the
customer. The second number indicates the structure revision. The third number
indicates the data revision.