Marine Radio User Manual

5 - 1
AD-92SMA
Optional SMA–BNC adaptor
1/8" (3.5 mm)
3-conductor plug
68 k
-
+
to [SP] jack
Audio generator
AC millivoltmeter
Power supply
13.5 V / 3 A
to [MIC] jack
FM Deviation
meter
Attenuator
40 dB or 50 dB
RF power meter
10 W/50
Frequency
counter
Standard signal
generator
CAUTION:
to the antenna connector
DO NOT transmit while
an SSG is connected to
the antenna connector.
JIG
5-1 PREPARATION
REQUIRED TEST EQUIPMENT
ENTERING THE ADJUSTMENT MODE
q Connect a 68 k terminator to the [SP] jack.
w Push and hold the [SQL] key, and then turn power ON.
Note: The frequency of wide range appears at the display using this operation.
CONNECTION
EQUIPMENT
DC power supply
RF power meter
(terminated type)
Frequency counter
FM deviation meter
GRADE AND RANGE
Output voltage : 13.5 V DC
Current capacity : 3 A or more
Measuring range : 1–10 W
Frequency range : 28–1500 MHz
Impedance : 50
SWR : Less than 1.2 : 1
Frequency range : 0.1–1500 MHz
Frequency accuracy : ±1 ppm or better
Sensitivity : 100 mV or better
Frequency range : 30–1500 MHz
Measuring range : 0 to ±10 kHz
EQUIPMENT
DC voltmeter
Audio generator
Standard signal
generator (SSG)
Oscilloscope
AC millivoltmeter
Attenuator
GRADE AND RANGE
Input impedance : 50 k/V DC or better
Frequency range : 300–3000 Hz
Measuring range : 1–500 mV
Frequency range : 28–1300 MHz
Output level : 0.1 µV–32 mV
(–127 to –17 dBm)
Frequency range : DC–20 MHz
Measuring range : 0.01–20 V
Measuring range : 10 mV–10 V
Power attenuation : 40 or 50 dB
SECTION 5 ADJUSTMENT PROCEDURES