Additions to FLASH Commands
B-49
B
The Flash Fill test fills Flash memory according to the current test
configuration parameters selecting:
❏ Starting and ending block
❏ The data to fill with
❏ An increment/decrement value
Command Input:
177-Diag>flash fill
Flash Patterns Test
The Flash Patterns test writes and reads various data patterns in
Flash memory according to the current test configuration
parameters selecting starting and ending blocks, and saving /
restoring of the Flash contents.
Note If you are running the Flash test and 177Bug itself
resides in Flash, the test will fail as shown in the
example below.
Command Input:
177-Diag>flash pats
177-Bug>sd
177-Diag>flash
FLASH TESTS:.....................................Running->FAILED
FLASH/TESTS Test Failure Data:
Flash tests must be called individually and will only execute from
PROM. On many boards 177Bug is running in Flash memory.