Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
50 23 0 ... 255Parameter of
load control KP
(LD-G-decoders
only)
(LD-G-30: 40)
(LD-G-31: 65)
(LD-G-32: 90)
(LD-G-33: 80)
(LD-G-34: 80)
= Proportional component of
the load control.
See "optimizing the driving
characteristics" at the end of
section 8., as well.
The parameter KP defines the basic speed. A too small value à locomotive too
slow. A too high value à heavy shaking of the locomotive.
51 24 0 ... 255Parameter of
load control KI
(LD-G-decoders
only)
(LD-G-30: 30)
(LD-G-31: 12)
(LD-G-32: 70)
(LD-G-33: 45)
(LD-G-34: 45)
= Integral component of the
load control.
See "optimizing the driving
characteristics" at the end of
section 8., as well.
The parameter KT provides the fine tuning of the load control. The value has to
be adjusted in very small steps.
A too high value à heavy shaking of the locomotive.
52 25 0 ... 255Parameter of
load control KD
(LD-G-decoders
only)
(LD-G-30: 40)
(LD-G-31: 40)
(LD-G-32: 40)
(LD-G-33: 50)
(LD-G-34: 50)
= Differential component of
the load control.
See "optimizing the driving
characteristics" at the end of
section 8., as well.
The parameter KD retards the transforming of the load control. A too small value
à shaking of the locomotive.
A too high value à vibrating of the locomotive.