Specifications

English Locomotive decoders 30s series
Page 38
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Switching off
at overload
(LD-G-30
and LD-G-33
only)
117 52 0...255
(LD-G-30: 64)
(LD-G-33: 69)
Determines, at which current
the overload protection
responds. With the LD-G-30
the value 64 corresponds to
700 mA, with the LD-G-33
the value 69 corresponds to
1,5 A.
Caution: A total current of more than 700 mA or 1,5 A can lead to damage of the
decoder due to overload. When for CV#117 a higher value than the default value
is set, the overload protection is not guaranteed.
Alternative dimming of the outputs:
AUX1, AUX2 118 54 1...255 (255)
LD-G-31, LD-G-33, LD-G-34, LD-W-33 only:
AUX3, AUX4 119 55 1...255 (255)
LD-G-33, LD-G-34, LD-W-33 only:
AUX5 / AUX6 120 56 1...255 (255)
= reduction of the voltage
applied to the output. The
value "1" corresponds to the
minimum, "15" to the max.
voltage. The values are only
valid for the outputs defined
in CV#116 and for the speed
level defined in CV#113.
It is possible to choose a value between 0 and 15 for any of the outputs. For the
outputs with an odd number the value is set directly, for the outputs with an
even number the input value has to be multiplied by 16.
Example:
For AUX5 value "14" and for AUX6 value "2"à input value: 46 (=14 + 2x16)