Specifications

RS-232 INTERFACE 7 - 3
RS-232 Parameter Defaults
Table 7-1 lists the defaults for RS-232 host parameters. If any option needs to be changed, scan the
appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 7-4.
NOTE See Appendix A, STANDARD DEFAULT PARAMETERS for all user preferences, hosts, symbologies, and
miscellaneous default parameters.
Table 7-1
RS-232 Host Default Table
Parameter Default
Page
Number
RS-232 Host Parameters
RS-232 Host Types Standard
7-6
Baud Rate 9600
7-8
Parity Type None
7-9
Stop Bit Select 1 Stop Bit
7-9
Data Bits (ASCII Format) 8-Bit
7-10
Check Receive Errors Enable
7-10
Hardware Handshaking None
7-12
Software Handshaking None
7-14
Host Serial Response Time-out 2 sec
7-15
RTS Line State Low RTS
7-16
Beep on <BEL> Disable
7-16
Intercharacter Delay 0 msec
7-17
Nixdorf Beep/LED Options Normal Operation
7-18
Ignore Unknown Characters Send Bar Code
7-18