Installation manual

Operation
24 025-9472D
monitor is required, the number of wildcard functions, and whether or not the LineCheck
function is desirable.
Table 10 and Table 11 describe each operating mode. This includes
the tone remote function tones, the action taken in response to each function tone, and
what each of the output signals does.
Table 12 describes the various functions and
capabilities referenced in the previous two tables.
Table 10: Model 250 Operating Modes 0 to 6
Mode Î 0 1 2 3 4 5 6
Description Ö 1 Frequency
Monitor
PL strip
6 Wildcard
1 Frequency
Monitor, 4 PL
PL strip
2 Wildcard
LineCheck
2 Freq
Monitor
6
Wildcard
2 Freq
Monitor
4 PL
2 Wildcard
LineCheck
4 Freq
(1 of 4)
Monitor
3 Wildcard
LineCheck
7 Freq
(1 of 7)
Monitor
Line CK
8 Freq
(Binary)
Monitor
4 PL
Switches 1-4 Ö
ÈÈÈÈ ÈÈÈÇ ÈÈÇÈ ÈÈÇÇ ÈÇÈÈ ÈÇÈÇ ÈÇÇÈ
2050 Hz Monitor Monitor Monitor Monitor Monitor Monitor Monitor
1950 Hz PTT PTT F1 F1 F1 F1 F1
1850 Hz
F1 + PL strip
F1 + PL strip F2 F2 F2 F2 F2
1750 Hz I/O 6 on I/O 6 on I/O 6 on I/O 6 on I/O 7 on F7 F7
1650 Hz I/O 6 off I/O 6 off I/O 6 off I/O 6 off I/O 7 off - F8
1550 Hz I/O 8 on I/O 8 on I/O 7 on I/O 7 on I/O 8 on - -
1450 Hz I/O 8 off I/O 8 off I/O 7 off I/O 7 off I/O 8 off - -
1350 Hz I/O 1 on PL 1 I/O 1 on PL 1 F3 F3 F3
1250 Hz I/O 1 off PL 2 I/O 1 off PL 2 F4 F4 F4
1150 Hz I/O 2 on PL 3 I/O 2 on PL 3 I/O 6 on F5 F5
1050 Hz I/O 2 off PL 4 I/O 2 off PL 4 I/O 6 off F6 F6
950 Hz I/O 3 on - I/O 3 on - - - PL 1
850 Hz I/O 3 off - I/O 3 off - - - PL 2
750 Hz I/O 4 on Line CK out I/O 4 on Line CK Line CK Line CK PL 3
650 Hz I/O 4 off Line CK in I/O 4 off Line CK Line CK Line CK PL 4
Functions
I/O 1 1350/1250 PL 1 1350/1250 PL 1 F1 F1
Freq Binary 1
I/O 2 1150/1050 PL 2 1150/1050 PL 2 F2 F2
Freq Binary 2
I/O 3 950/850 PL 3 950/850 PL 3 F3 F3
Freq Binary 4
I/O 4 750/650 PL 4 750/650 PL 4 F4 F4 PL1
I/O 5 Monitor Monitor Monitor Monitor Monitor Monitor Monitor
I/O 6 (or COR)
1750/1650 1750/1650 1750/1650 1750/1650 1150/1050 F7 PL4
I/O 7 (SPST rly)
PL strip PL strip 1550/1450 1550/1450 1750/1650 F6 PL3
I/O 8 (SPDT rly)
1550/1450 1550/1450 F1 / F2 F1 / F2 1550/1450 F5 PL2
Note: I/O outputs 1 through 6 are active low, open drain FETs. On = Low, Off = High.