USER’S GUIDE Smart Ear Thermometer Model: MBP69SN Please read this instruction manual before use
Welcome… to your new Motorola MBP69SN Smart Ear Thermometer!! Thank you for purchasing your new Motorola MBP69SN Smart Ear Thermometer. The device is intended for the intermittent measurement and monitoring of human body temperature by consumers at home. Research indicates that the ear is an ideal site for taking body temperature, because body temperature is regulated by the hypothalamus, which shares the same blood supply as the eardrum. As such, it is best to take the ear temperature as much as possible.
For product-related questions, please call: US and Canada, 1-888-331-3383 E-mail: support@motorolastore.com On the Web: www.motorolastore.com/support This User’s Guide has all the information you need to make the most out of your product. Please read the Safety Instructions on page 7 before you install the unit.
Overview of the Thermometer 1 2 3 4 7 1. 2. 3. 4. 5. Protective cap Infra-red sensor Temperature measuring button LCD LED (green or red) 5 6 8 6. 7. 8.
LCD Display 1. 2. 3. 4. 5. 6. 7. 8.
Table of contents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. IMPORTANT SAFETY INFORMATION.......................................................................7 BODY TEMPERATURE..................................................................................................10 PRIOR TO USE.................................................................................................................. 11 SYSTEM REQUIREMENT............................................................................................
To obtain an accurate measurement, please read this manual carefully prior to use. • Use of this thermometer is not intended as a substitute for consultation with your physician. • Measurement results are for reference only. Contact your physician if you experience or suspect any health concerns. • The infra-red sensor must be completely clean, dry and undamaged to ensure accurate measurements. • Because earwax in the ear canal may cause inaccurate measurements, ensure that the ear canal is clean.
• Do not use the product if the ear canal is wet after swimming or bathing. Doing so may damage the ear canal. • Do not use the thermometer if the device is damaged (for example, if the infra-red sensor is broken). Continued use of a damaged unit may cause injury, inaccurate results or serious hazard. • Do not disassemble, repair or change any parts of the unit. • If your thermometer will not be used for a long time, remove battery to prevent possible damage caused by chemical leakage.
Important Safety Information 9 ENGLISH Caution: This device should not be used adjacent to or stacked with other equipment. Should adjacent or stacked use be necessary, this device should be observed to ensure normal operation in the configuration in which it will be used.
2. BODY TEMPERATURE Normal body temperature is a range. A person’s normal temperature range tends to decrease with age. The following table shows normal temperature ranges by age: Normal temperature ranges by age: 0 - 2 years 36.4 - 38.0 °C 97.5 - 100.4 °F 3 - 10 years 36.1 - 37.8 °C 97.0 - 100.0 °F 11 - 65 years 35.9 - 37.6 °C 96.6 - 99.7 °F > 65 years 35.8 - 37.5 °C 96.4 - 99.5 °F Source: Chamberlain, J.M., et al.
1. 2. 3. 4. The key to obtaining accurate readings is a clean sensor. To clean the sensor, use a cotton swab slightly moistened with alcohol to gently wipe its surface, and then immediately wipe dry using a clean cotton swab. Wait at least 20 minutes to make sure that the sensor is completely dry before taking temperature. Make sure the ear canal is clean. If you have cleaned the ear, please wait for 5 to 10 minutes before measuring temperature.
4. SYSTEM REQUIREMENT Smartphones/Tablets: Android™ and iOS® only. System Requirements: iOS 8.0, Android™ 4.2 or above For more information, please visit: https://hubbleconnected.
ENGLISH 5. PAIRING THE THERMOMETER TO YOUR MOBILE DEVICE Download the “Hubble Connect for Smart Nursery” app • Go to the Google Play™ Store to search for Hubble Connect for Smart Nursery. • Download the Hubble Connect for Smart Nursery app and install it on your Android™ device or • Go to the App Store to search for Hubble Connect for Smart Nursery. • Download the Hubble Connect for Smart Nursery app and install it on your iPhone®/iPad®.
Launch the set-up wizard and follow the steps to create a user profile and add the thermometer. Make sure that the Smart Nursery app is active and that Bluetooth on your mobile device is activated when pairing is in progress. • Run the Hubble Connect for Smart Nursery app, tap SIGNUP and follow the in-app instructions to create your Smart Nursery Account. By signing up, you agree to our Terms & Conditions.
ENGLISH • Tap on the Smart Ear Thermometer to enter thermometer set-up mode. (Picture A3) A3 • Tap Skip to set-up or scroll to review features.
• Follow “Step 1”. Make sure that your thermometer is switched on then press Next. (Picture A5) A5 • Follow “Step 2”. Pair the thermometer with your mobile device via Bluetooth.
ENGLISH • Searching for your device (Picture A7) A7 • Found your device. Please press on “MBP69-XXX”.
• Pairing the thermometer with your smart device. (Picture A9) A9 • You have now successfully paired the thermometer with your smart device.
ENGLISH • User guide screen. (Picture A11) A11 • You can now start using the thermometer. (Picture A12) A12 Note: Your personal health data can only be transmitted when the app is on. The thermometer switches off automatically after 60 seconds of non-use.
6. OVERVIEW OF HUBBLE APP Overview of the Hubble App 20 Total of 4 profiles To create and add the profile Online Indicates that the thermometer is connected to the smartphone. Offline Indicates that the thermometer is not connected to the smartphone. Number of readings Indicates the numbers of temperature readings taken Schedule Manager Calendar to manage doctor appointments, reminders and prescriptions.
ENGLISH 7. TEMPERATURE LED INDICATION Two colors are used to provide LED indications: • Green LED: 34.0°C (93.2°F) to 37.9°C (100.3°F) = Normal temperature • Red LED: 38.0°C (100.4°F) to 42.9°C (109.
8. TEMPERATURE TAKING HINTS 1. A temperature measurement taken from the right ear may differ from a measurement taken from the left ear. Therefore, please take the temperature in the same ear. 2. External factors may influence ear temperature. Specific external factors include: • Lying on one ear • Having one’s ears covered • Exposure to a very hot or very cold location. • Recent swimming or bathing.
1. Remove the protective cap prior to use. Make sure the probe is clean before measuring. Place the thermometer in your hand with your thumb or forefinger on the [ ] button. • Do not press the button yet. 2. Insert the probe very gently and slowly into the ear canal. • Hold the thermometer such that the probe is oriented straight in the direction of the eardrum. • It is important to point the thermometer’s probe window toward the eardrum properly inside the ear.
3. 4. 5. 6. 7. 24 Press the [ ] button to start measuring until you hear two ‘DIDI’ beeps (approx. 1 second). The measurement is complete. Remove the thermometer from the ear canal. The LCD displays the measured temperature. A new measurement can only be taken 6 seconds after the previous temperature measurement or after the green/red LED turns off. If the “cleaning” symbol is flashing on the LED screen, please clean the infra-red sensor. Press any button to stop flashing.
ENGLISH 10. HOW TO MEASURE OBJECT (LIQUID) TEMPERATURE Changing the measurement mode 1. 2. Place the thermometer in your hand with your finger on the [ Press the [ ] button, then the thermometer enters the object/liquid temperature measuring mode. Note: Do not use this mode to measure body temperature. Hold the thermometer and ensure the probe is approximately 0.5cm (1/4 inches) from the liquid or surface whose temperature you want to measure. Press the [ 3. ] button. ] button to start.
11. CHECK THE MEMORY There is a total of 4 users; each user can store up to 50 sets of memory data for recording ear temperature measurements. The current measurement is always stored in the last storage space. When all storage spaces have been occupied, the earliest measurement is always deleted from the memory. Press the [ ] button to check the memory data. The LCD screen displays memory number and measured temperature. Press the [ ] button repeatedly to go to the desired memory number.
ENGLISH 12. CELSIUS/FAHRENHEIT OPTION In standby mode, you can switch between Celsius (°C) and Fahrenheit (°F) by pressing and holding [ “beep” sounds.
13. REPLACING THE BATTERY When the low battery indicator “ ” appears on the LCD screen, or if the thermometer fails to operate, you should insert a new battery as soon as possible. The thermometer comes with two batteries (2×AAA). Remove the battery cover, remove the batteries, then insert new AAA batteries into the battery compartment. Be sure to properly install the batteries, in accordance with the positive and negative polarity symbols marked in the battery compartment.
ENGLISH 14. DISPOSAL OF THE DEVICE (ENVIRONMENT) At the end of the product life cycle, you should not dispose of this product with normal household waste. Take this product to a collection point for the recycling of electrical and electronic equipment. The symbol on the product, user’s guide and/or box indicates this obligation. By taking end-of-life products to a recycling point, you are ensuring that some of the product materials can be re-used.
15. GENERAL INFORMATION If your product is not working properly.... 1. Read this User’s Guide. 2. Visit our website: www.motorolastore.com 3. Contact Customer Service at US and Canada 1-888-331-3383 E-mail: support@motorolastore.com Consumer Products and Accessories Limited Warranty (“Warranty”) Thank you for purchasing this Motorola branded product manufactured under license by Binatone Electronics International Ltd (“BINATONE”).
Products Covered Length of Coverage Consumer Products One (1) year from the date of the products, original purchase by the first consumer purchaser of the product. Consumer Accessories Ninety (90) days from the date of the Accessories, original purchase by the first consumer purchaser of the product. Consumer Products and The balance of the original warranty or for Ninety Accessories that are (90) days from the date returned to the consumer, Repaired or Replaced whichever is longer.
Abuse & Misuse. Defects or damage that result from: (a) improper operation, storage, misuse or abuse, accident or neglect, such as physical damage (cracks, scratches, etc.
General Information 33 ENGLISH These terms and conditions constitute the complete warranty agreement between you and BINATONE regarding the Products or Accessories purchased by you, and supersede any prior agreement or representations, including representations made in any literature publications or promotional materials issued by BINATONE or representations made by any agent employee or staff of BINATONE, that may have been made in connection with the said purchase.
16. DESCRIPTION OF THE WIRELESS FUNCTIONS AND TECHNOLOGY RF Frequency 2.4GHZ-2.48GHZ Channel Bandwidth 2 MHz (-20 dB) Operation Voltage DC 3V Types of Spread Spectrum FHSS Modulation Type GFSK Number of Channel 40 Chanel Spacing 2 MHz ChannelFrequency 0-39 Channel 2.402-2.480GHZ Dwell Time (if FHSS) 400 ms Hopping Rate (if FHSS) 1600 HZ Antenna Gain 0 dBi Bluetooth Version V4.1 Maximum Output Powers 0 dBm 1. 2. 34 BLE4.1 devices operate in the unlicensed 2.
3. 4. 5. 6. 7. Description Of The Wireless Functions And Technology 35 ENGLISH connected to other wireless devices or controllers. Once the app connects to the peripheral device, the app will transmit the appropriate command, and once MBP69SN confirms that this command is correct, it will open the control panel, enabling the user to control the MBP69SN device. Otherwise, the app can’t control the MBP69SN device. Make sure that the device is connected and controlled by our app.
17. CARE AND CLEANING To ensure accurate measurements, it is very important to keep the infra-red sensor clean and free of scratches. Fingerprints and dirt will affect the accuracy of the thermometer. In order to get an accurate measurement, please clean the infra-red sensor. Gently wipe its surface with a cotton swab slightly moistened with alcohol and immediately wipe dry with a clean cotton swab. Use a soft dry cloth to clean the body of the thermometer.
Problem Category Problem Description/ Error No response / Automatic Are the batteries reset after insulator is drained? pulled out Are the batteries installed according to the wrong polarity? The measured temperature is lower than 34.0°C/93.2°F or higher than 42.9°C/109.3°F. Please check the operation method Hardware problem ENGLISH 18.
Problem Category Problem Description/ Error Inaccurate measurement Please check whether or where there is any the infra-red sensor is doubt regarding the clean measured reading Please check if the proper measurement method was used Solution The app can’t connect to the MBP69SN device The app can’t control the MBP69SN device, but the app is connected to it Restart MBP69SN and the app Restart the app, and then re-connect the device Clean the infra-red sensor with a cotton swab in accordance with the user
ENGLISH 19. NORMALIZED SYMBOLS Type BF applied part (the applied part is the probe tip) Caution Refer to the Instruction Manual. IP22 The first number (2): Protection against solid foreign objects of 12.5 mm Ф and greater. The second number: Protection against vertically falling water drops when enclosure is tilted up to 15°. Vertically falling drops shall have no harmful effects when the enclosure is tilted at any angle up to 15°, on either side of the vertical.
20. IMPORTANT INFORMATION REGARDING ELECTROMAGNETIC COMPATIBILITY(EMC) With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation. Medical devices should also not interfere with other devices.
The thermometer is intended for use in the eIectromagnetic environment specified below. The customer or user of this thermometer should ensure that it is used in such an environment. Emissions Test Compliance Electromagnetic Environment Guidance RF emissions CISPR 11 Group 1 The thermometer only uses RF energy for its internal operation. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
Guidance and Manufacturer’s Declaration – Electromagnetic Immunity The thermometer is intended for use in the electromagnetic environment specified below. The customer or user of these thermometers should ensure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment – Guidance Electrostatic discharge (ESD) IEC 61000-4-2 ±6 kV contact ±8 kV air ±6 kV contact ±8 kV air Floors should be made of wood, concrete or ceramic tile.
The thermometer is intended for use in the electromagnetic environment specified below. The customer or user of this thermometer should ensure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Electromagnetic Environment Level – Guidance Conducted RF IEC 61000 -4-6 3 V/m Not applicable 3 V/m Radiated RF 80 MHz to IEC 61000-4-3 2.
should be less than the compliance level in each frequency range. Interference may occur in the vicinity of equipment marked with the following symbol: Note 1: At 80 MHz and 800 MHz, the higher frequency range applies. Note 2: These guidelines may not be applicable in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
ENGLISH Recommended Separation Distance Between Portable and Mobile RF Communications Equipment and the Thermometer The thermometer is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
21. FCC AND IC REGULATIONS (FCC PART 15) Warning: Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Fcc And Ic Regulations (fcc Part 15) ENGLISH Operation is subject to the following Two conditions:(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
22. SPECIFICATIONS Power supply: DC 3V (2 x AAA battery) Ear measurement range: 34.0°C to 42.9°C (93.2°F to 109.3°F) Ear measurement accuracy: ±0.2°C(±0.4°F) Object measurement range: -22°C to 80.0°C (-7.6°F to 176.0°F) Object measurement accuracy: ±2.0°C (±4.0°F) Measurement time: 1 second Measurement interval: 1 second Dimensions: 132.8(L)x37.3(W)x32.2(D)mm Weight: About 50.5g (without battery) Operating conditions: 10.0°C to 40.0°C (50.0°F to 104.
Manufactured, distributed, or sold by Binatone Electronics International LTD., official licensee for this product. MOTOROLA and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings, LLC. and are used under license. Apple logo is a trademark of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play and Android are trademarks of Google Inc. All other trademarks are the property of their respective owners.