Typewriter User Manual

5- 62 MC68340 USER’S MANUAL MOTOROLA
15 0
SP STATUS REGISTER
+$02 RETURN PROGRAM COUNTER HIGH
RETURN PROGRAM COUNTER LOW
+$06 1100 VECTOR OFFSET
+$08 FAULTED ADDRESS HIGH
FAULTED ADDRESS LOW
+$0C DBUF HIGH
DBUF LOW
+$10 CURRENT INSTRUCTION PROGRAM COUNTER HIGH
CURRENT INSTRUCTION PROGRAM COUNTER LOW
+$14 INTERNAL TRANSFER COUNT REGISTER
+$16 0 0 SPECIAL STATUS WORD
Figure 5-15. Format $C—BERR Stack for Prefetches and Operands
15 0
SP STATUS REGISTER
+$02 RETURN PROGRAM COUNTER HIGH
RETURN PROGRAM COUNTER LOW
+$06 1100 VECTOR OFFSET
+$08 FAULTED ADDRESS HIGH
FAULTED ADDRESS LOW
+$0C DBUF HIGH
DBUF LOW
+$10 CURRENT INSTRUCTION PROGRAM COUNTER HIGH
CURRENT INSTRUCTION PROGRAM COUNTER LOW
+$14 INTERNAL TRANSFER COUNT REGISTER
+$16 0 1 SPECIAL STATUS WORD
Figure 5-16. Format $C—BERR Stack on MOVEM Operand
Frees
cale Semiconductor,
I
Freescale Semiconductor, Inc.
For More Information On This Product,
Go to: www.freescale.com
nc...