Barcode Reader User Manual

5 - 12 MC9090-G RFID Integrator Guide Supplement
9. Tap Erase to erase an unlocked tag.
10. Tap Lock to lock a tag so that it cannot be changed. A lock/kill code is required to lock a tag. See Program Tag
on page 5-11.
11. Tap Kill to make a tag unreadable. A lock/kill code is required to kill a tag. (See Program Tag on page 5-11.)
12. Tap Back to Global Scroll to return to the main Tags window.
NOTE For a successful tag read, the allowable read distance from the front of the mobile computer scan exit
window to the tag is 0.2 ft - 10 ft (0.061 m to 3.1 m).
NOTE To successfully write data to a tag, the tag must be no less than 1 ft (.31 m) from the antenna and no
greater than 2 ft (.61 m) from the antenna.